Loading...
Site Plan of 612 St. Jamesf GENERAL NOTES L ALL CONSTRUCTION TO COMPLY WITH APPLICABLE BUILDING CODES, DEED RESTRICTIONS, ANO RELATED REGULATIONS. 2. BRING ALL ERRORS, OMISSIONS, ANO DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT, 3. NOTIFY THE ARCHITECT IN THE EVENT OF INCONSISTENCIES BETWEEN ACTUAL FIELD CONDITIONS ANO THE CONSTRUCTION DOCUMENTS. 4. STRUCTURAL, MECHAI~CAL, LIGHTING, LANDSCAPE, AND ANY OTHER ADDITIONAL CONSULTANTS ARE TO BE CONTRACTED BY THE OWNER. 5, VERIFY LOCATION OF ALL UTILITIES SERVING THE SITE. FOR DIMENSIONING PURPOSES: a. DO NOT SCALE DRAWINGS. b. ALL INTERIOR WALLS ARE 2X't STUDS OIMENSiONED TO ONE FACE OF STUD AT 3 I/2' TYPICAL c. STRUCTURAL WALLS WITH 2X4 STUDS AT 16' O.C. ARE EXCEPTABLE OI~.Y TO A HEIGHT OF I0 FEET. 2X4 STUD WALLS EXCEDING !0 FEET IN HEIGHT WILL REQUIRE STRUCTURAL ANAL'f SIS TO VERIFY STUD SPACING AND OR ADDITIONAL BRACING. d. ALL iNTERIOR WALLS OTHER THAN 2X4 STUDS WILL BE DIMENSIONED ' OUT TO OUT ' OR FACE OF STUD TO OPPOSITE FACE OF STUD,ie; 2X6'S - 5 1/2'. 2X8'S - ? 1/~'. ETC. e, EXTERIOR MASONRY WALLS ARE AS FOLLOWS; 2X~',~ 9' FACE OF MASONRY TO FACE OF STUO. 2X6'~ I1' FACE OF MASONRY TO FACE OF STUD, ?, PLATE ' WALL · HEIGHTS ARE REFERENCED ON THE FiOOF PLAN AND THE ELEVATIONS. THEY ARE TO BE COORDINATED WITH THE EAVE AND RAKE DETAILS. & CONSTRUCTION ASSEMBLY SYSTEMS ARE SPECIFIED ON THE WALL SECTIONS AND REFERENCED TO IN SUBSEQUENT DETAILS. 9. REFERENCE FLOOR PLANS FOR WINDOW SIZE AND HEAD HEIGHT UI~.ESS A WINDOW SCHEDULE IS PROVIDED. I0. UI~I. ESS SHOWN ON PLANS, HVAC, AND WATER HEA'~ER LOCATION AND SERVICE REQUIREMENTS TO BE DETERMINED BY OTHERS. IL LOCATION AND SIZE REQUIREMENTS FOR HVAC DUCT CHASES TO BE VERIFIED BY HVAC SYSTEM DESIGNER. COORDINATE THE LOCATION OF NEW OR LARGER CHASES WITH THE ARCHITECT. 12. LOCATE KITCHEN COOKTOP VENTHOOD EXHAUST [:AN MOTOR IN THE ATTIC. 13. SLEAVE ALL COPPER PIPE PENATRATIONS THROUGH CONCRETE SLABS OR WALLS, 14. LOCATE SHOWER HEADS AT ?'-0 A.F.F, UNLESS NOTED OTHERWISE ON PLANS. 15. FOAM SEAL ALL INTERIOR AND EXTERIOR WALL CAVITY OPEI~INGS, i,e. HOSE BIBS, ELECTRICAL BOXES, ETC. 18. SEAL ALL SILL PLATES. IT. PROVIDE SOLID LUMBER BLOCKING IN WALL FOR MISCELLANEOUS FIXTURES, AND HARDWARE, i.e. TOWEL BARS, CLOSET SHELVING, CABINETS, CEILING FANS, ETC,, WHERE SUCH FIXTURES ARE INDICATED ON THE PLANS. 18. GENERAL CONTRACTOR TO VERIFY THAT THE WINDOWS USED WHERE EGRESS IS REQUIRED, MEET THE APPLICABLE CODE. 19. ALL PERIMETER DRAIN SYSTEMS ARE TO BE TIED TO A SUMP PUMP UNLESS THE NATURAL GRADE PERMITS A SLOPED DRAIN TO DAYLIGHT. 20. VENT CLOTHES DRYER TO OUTSIDE IN OCCuRDAI~;E WITH APPLICABLE CODES. 21. ADJUST THE HEIGHT OF FLOOR STRUCTURE TO ALIGN ALL FINISH SURFACES Ut4..ESS SPECIFICALLY INDICATED OTHERWISE. SQUARE FOOT A GE T AB., A.C. MISCEL. LOCATION s u,.E FOOTAGE FOOTAGE PROPOSED FIRST FLOOR 613 PROPOSED SECOND FLOOR 467 TOTAL 1080 AIR CONDITIONED SPACE COVERED PORCHES 4T GARAGE 591 TOTAL 1718 UNDER ROOF TERRACES - COMBINED LOT SIZE 25998.18 TOTAL LOT COVERAGE 1251 LOT COVERAGE Y. 4.81~. 135.O1' ,5 OO"-OO'-OO'E q,r-2 3/'¢ T TERRACE 25' E~,J~LDDiG SETBACK LOT SE; BLOCK B ~q~OSOE ESTATES N:)OIT1Ofl PROPOSED NOME EXTENSION CONCRETE MOTOR COURT 'AC Area= - :,: .'-': .'-' - STO~ PILLARS ': .(;' L':"; AT 20'--O' O.C. MTN A FOOT~ T~T STONE TO ~" ~'C~I A~O ~RO~GHT iROn, FENCE / .¢ / / / / / / / / / / / / / / / / / / / I / / I / / / / / / / / / / / / / / / / / ./ / / /' / / / / / / / / / / / / /' / / / SITE PLAN SCALE = Vii,' = r-o' d 0 DRAWN BY CZ CHECKED BY 2. 3. 4. 5. 6. T. ISSUE DATE ~1-10-03 REVISIONS SHEET NUMBER Al,1 PROJECT NUMBER 03024