Loading...
DRC commentsCOl'FELL Project ID SUP-04-0002 Address 950 E Sandy Lake Rd CITY OF COPPELL DRC REPORT Proiect Name Kroger COl'FELL Project Type Application Date Case Manager Project Description Special Use Permit 1/20/04 Marcie Diamond zoning change request from C-S-1098R (Commercial-Special Use Permit 1098R) to C-S-1006R2 (Commercial, Special Use Permit-1098-Revision-2), to allow a drive-through pharmacy with canopy along the west side of the existing grocery store Agency Building Inspection Electric and Gas Engineering Fire Administration Parks and Recreation Planning Depadment 1 of 1 Reviewed By Review Date Greg Jones 2/26/04 Jeff Curry 1/30/04 Ken Griffin 2/24/04 Vernon Gilmore 2/25/04 John Elias 2/24/04 Marcia Diamond 2/24/04 Comments 1. No comments. Zoning Change Acceptable No Comments. No Comment No comments. Overall Comment: The proposed drive-through pharmacy would be more appropriate, from a land use compatibility perspective, on the east side of the building, adjacent to MacArthur Blvd, however, understanding the internal layout of the store, and the desire to place this drive-through on the west side of the building, the following technical comments need to be addressed on the REVISED Plan: Site Plan: 1. Resolve inconsistencies between the dimensions of the canopy shown on the site plan, versus the dimension on Detail 5 on the Sheet of Details. 2. Site Data Box: correct the Proposed Zoning to "C-S-1098R2" instead of"C-S-1006R2" 3. Clarify Note #1 - When will the light under this canopy be on? Will it exceed the hours of operation of the drive-through? 4. Revise Note #3 - to specify that the hours of operation are for the drive-through pharmacy only. 5. We received a complaint from a homeowner to the north, and verified it though a site visit, that it appears that there are approximately 15 trees missing from the north side of the building, as required on the approved site landscape plan (see attached). 6. Provide information on the site plan concerning the timing of the exterior lights on the north and west sides of the building. Detail Sheet: 1. Specify the color, size and materials of the proposed "ENTER" and "EXIT" signs. Will these signs be internally illuminated? 2. Resolve inconsistencies between the notes on the Site Plan and the Sheet of Details in terms of the color of finish for the E.F.I.S. - will it be "ivory to match the accent of the existing building" (Site Plan note) or "finish to match adjacent surfaces" (Side Elevation note)? 3. Will the existing light fixture above the proposed canopy remain? L\ I__