Loading...
DRC commentsDEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: Sandy Lake Crossing Addition, Lot 2R~ Block 1, Replat, being a replat of Lot 2, Block 1 of the Sandy Lake Crossing Addition, to allow the construction of an approximate 7,200-square-foot retail building on 0.737 of an acre of property located along the south side of Sandy Lake Road, approximately 200 feet west of Denton Tap Road, at the request of Thomas J. Whan, Creekside Construction Ltd. STAFF REP.: Marcie Diamond PROJECT ID# RP-04-002/I DRC DA TE: April 29, 2004 and May 6,2004 CONTACT: Kenneth M. Green, P.E., Dir. o/ Engineerin~/Public Works 972/304-3686 COMMENTSTATUS: t>~,~ ta~nra t>~7 ~FIIVAI t~w~/t~wtl Plat - I. Provide 5' sidewalk/utility easement adjacent to north property line. Utilities PLan - 1. Provide one tap to the 8" water line with the domestic and irrigation taps off the 8" water line. The fire line vault needs to be in a 15' x 15' utility easement. Additional comments may be generated and a need for additional easements may be identified as a result ora detailed engineering review. COl'FELL Project ID RP-04-0024 Address 105 W Sandy Lake Rd CITY OF COPPELL DRC REPORT Project Name Sandy Lake Crossing Addition, Lot 2R, Block 1 Project Type Application Date Case Manager Project Description Replat 4/21/04 Marcie Diamond Being a replat of Lot 2, Block 1 of the Sandy Lake Crossing Addition, to allow the construction of an approximate 7,200-square-foot retail building Agency Building Inspection Electric and Gas Engineering Fire Administration Parks and Recreation Planning Department 1 of 1 Reviewed By Review Date Greg Jones 4/28/04 Jeff Curry 4/30/04 Ken Griffin 4/29/04 Tim gates 4/30/04 John Elias 4/27/04 Marcie Diamond 4/27/04 Comments 1. No comments made. No Comments Received Plat - 1. Provide 5' sidewalk/utility easement adjacent to north property line. Utilities Plan - 1. We need a fire hydrant onsite with location to be specified by the Fire Marshal. 2. Domestic and irrigation services need to be off the main waterline, not the fire line, with meters located in the public right-of-way or a utility easement. 3. A fire vault is needed on the fire line with a double detector check inside the vault. 4. I recommend an 8" waterline with a 6" branch to a hydrant onsite and a 6" branch to the building for sprinkler purposes, 5. An FDC connection should be made within 50' of the fire hydrant. 6. The driveway connection to Sandy Lake Road needs to be reconstructed with concrete; it is in substandard condition. Additional comments may be generated and a need for additional easements may be identified as e result of a detailed engineering review. No Comment No comments. 1. Add '"'Being a replat of Lot 2, Block 1" to the title block. 2. Change the city name in the Owner's and Surveyor's certificates from Chapel to Coppell. 3. Change AT&T Broadband to Comcast 4. Change Oncor Electric and Gas to Oncor Electric Delivery Company and a separate signature line for TXU Gas.