Loading...
DRC commentsCOFFELL Proiect ID SPA-04-0064 Address 632 E Sandy Lake Rd CITY OF COPPELL DRC REPORT Proiect Name COFFELL Rozas Addition, Lot 1. Block A, Site Plan ProiectType Application Date Case Manager ProiectDescription Site Plan Approval 9/22/2004 Matt Steer to allow the construction of a 5,612-square- foot dental/medical office building on 0.98 of an acre of property Agency Building Inspection 1 of 2 Reviewed By Review Date Greg Jones 9/28/2004 Electric and Gas Jeff Curry 10/1/2004 Engineering Ken Griffin 9/30/2004 Fire Administration Tim Oates 10/1/2004 Parks and Recreation John Elias 9/29/2004 1. Medical gas must comply with 2000 IFC (fire code) requirements - Article 3006. 2. X-ray rooms must be designed by a licensed medical physisist. Need certification number submitted with permit drawings. 3. Provide automatic fire protection system. Site Plan Acceptable 1. Private utilities should not be located within a public utility easement. 2. Locate water meters in right-of-way. 3. Locate FDC adjacent to proposed fire hydrant. See additional comments on plat case. 1. Fire dept. connection must be detached from building. 1. Tree Removal Permit required prior to start of construction. CO??ELL Agency Planning Department Reviewed By Matt Steer CITY OF COPPELL DRC REPORT Review Date 9/30/2004 CO?PELL Comments Detail Site Plan 1. Add Lot # and Block letter to title block. 2. Parking required should be one per 175 square feet. This would calculate to 33 required including handicap. 3. Move the monument sign 5' west to meet the minimum 75' spacing requirement from the property line. 4. Verify right-of-way of Sandy Lake Road. 5. Remove utility lines from site plan. 6. Add stamped concrete to entry (brick pavers may be used if located on private property). Landscape Plan 1. Add Lot # and Block letter to title block, 2. Double check all figures within the Landscape table 35 DBH shown on plan with 29 represented in chart, 64 LHC shown with 8 represented, and 194 LM shown with 186 represented). 3. Revise required Nonvehicular landscaping figure to show 37,076 X 15% = 5,561. 4. Ensure 50% of the Nonvehicular Landscaping is located in the front yard. 5. Revise landscaping along Sandy Lake to show Cedar Elms as the dominant street tree. 6. 1 tree per 40' is required along primary image zones and adjacent to residential zoning. Revise. 7. Landscape additional islands within the parking area. These can count towards the deficiency in Nonvehicular Landscaping. 8. Recalculate required and provided trees per Landscape Ordinance (after all revisions have been made). Elevations 1. Revise monument sign to a maximum size of 40 square feet. 2. Examine additional methods to break-up the expanse of the roof. 3. There are no proposed attached signs; therefore, none will be allowed. 4. Provide color and material type within black end white elevations. Provide a sample of all materials to be used within a color board (examples available in Planning Department). 5. Give the percentage of each building material to be used on the structure. 6. It may be beneficial to provide a color rendering for the PowerPoint presentation to be made by staff. COl'FELL Proiect ID MP-04-0065 Address 632 E Sandy Lake Rd CITY OF COPPELL DRC REPORT Prolect Name COl'FELL Rozas Addition, Lot 1, Block A Project Type Minor Plat Application Date 9/23/2004 Case Manager Proiect Description to allow the construction of a 5,612-square- foot dental/medical office building on 0.98 of an acre of property Agency Building inspection Electric and Gas 1 of 2 Reviewed By Review Date Greg Jones 9/28/2004 Jeff Curry 10/1/2004 Engineering Ken Griffin 9/30/2004 Comments 1. No platting comments made. Plat Unacceptable, please contact Larry Redick at 972-323-8917 to discuss electric easement requirements and George Melindez at 972-485-6204 to discuss gas easement requirements. Also please change the "Receipt Acknowledgement" for separate signatures for TXU Electric Delivery and TXU Gas. Plat 1. Remove utility easements from area of private utilities. 2. Provide a permanent drainage easement over the existing inlet structure in the northwest corner of the property. Utility Plan 1. Locate water meters within the right-of-way. 2. Construct vault with DDC in 25' x 25' utility easement over fire line. 3. Provide some documentation indicating an agreement is in place to share maintenance and cost sharing between property owners for the private water line. 4. Locate the FDC adjacent to the proposed fire hydrant. 5. Provide private utility easements over shared water line. 6. Sewer will need to be extended along the east property line from the existing manhole in the right-of-way to the manhole to the northeast of this development. No trees should be planted within the utility easement. Fire Administration Tim Oates 10/1/2004 Parks and Recreation John Elias 9/29/2004 No comments. COl'FELL Agency Planning Department Reviewed By Matt Steer CITY OF COPPELL DRC REPORT Review Date 9/30/2004 COl'FELL Comments 1. There is a conflict between the required trees and the location of the needed sewer line. Please coordinate with the Engineering Department to determine an alternative location of the sewer line. 2. Remove landscape setbacks from the plat. 3. Ensure easements shown on site plan are adequately represented on the plat and vice versa. 4. Place al~ signature blocks on the plat (one page preferable). 5. Re-title as a Minor Plat, and indicate the Lot # and Block letter. 6. Verify right-of-way of Sandy Lake Road. COFFELL Project ID SPA-04-0064 Address 632 E Sandy Lake Rd CITY OF COPPELL CO?FELL 2nd DRC REPORT Project Name Rozas Addition, Lot 1, Block A, Site Plan Proiect Type Application Date Case ManaRer Project Description Site Plan Approval 9/22/2004 Matt Steer to allow the construction of a 5,612-square- foot dental/medical office building on 0.98 of an acre of property Aflency Engineering Comments No Comments. 1 of 1