DRC commentsCOl'FELL
Pr~ieet [D FP-04-00~7
Address
CITY OF COPPELL COFFELL
2nd DRC REPORT ,~~~
Prelect Name Sherrill Acres, Lot 3, Block 1, Final Plat
Prelect Type
Application Date
Case ManaRer
Project Description
Final Plat
9/22/2004
Marcie Diamond
located south of East Belt Line Road, approximately 2,150 feet east of MacArthur Boulevard, at the request of Allen and
Ridinger Consulting, Inc.
Aqency
Engineering
1 of 1
Comments
Plat
1. Water easement should be re-labeled as "Utility Easement",
2. The above noted easment should be located over the proposed water vault.
Utility Plan
1. The FDC shall be located on the same side of the fire lane as a fire hydrant.
CO?FELL
Project ID FP-04-0067
Address
CITY OF COPPELL
DRC REPORT
Proiect Name
COl'FELL
Sherrill Acres, Lot 3, Block 1, Final Plat
Project Type
Application Date
Case Manager
Project Description
Final Plat
9/22/2004
Marcie Diamond
located south of East Belt Line Road, approximately 2,150 feet east of MacAdhur Boulevard, at the request of Allen and
Ridinger Consulting, Inc.
Agency
Building Inspection
Electric and Gas
1 of 2
Reviewed By Review Date
Greg Jones 9/28/2004
Jeff Curry 10/1/2004
Engineering Ken Griffin 9/30/2004
Comments
1. No platting comments made.
Plat Unacceptable, please contact Larry Redick at
972-323-8917 to discuss electric easement
requirements and George Melindez at 972-485-6204
to discuss gas easement requirements. Also please
change the "Utility Certificate" for separate signatures
for TXU Electric Delivery and TXU Gas.
Plat
1. Pdvate utilities on the site should not be located in
utility easements.
Drainage Plan
1. Show any off-site drainage that may impede this
site.
Utility Plan
1. The water line on the west side of this property is
public, and the line on the east side is private. The
line you are proposing will be private.
2. Construct a vault with DDC where you connect to the
public line.
3. Irrigation and domestic water shall be off the public
line.
4. The vault and meters should be located with a
public utility easement.
5. An FDC needs to be provided and located within 50
feet of a fire hydrant.
Fire Administration Tim Oates 10/1/2004 1. No comments concerning the plat.
Parks and Recreation John Elias 9/29/2004 No comments.
CO??ELL
Agency
Planning Department
Reviewed By
Marcie Diamond
CITY OF COPPELL
DRC REPORT
Review Date
9/29/2004
COFFELL
Comments
1. This is a FINAL plat instead ora MINOR plat
because it was a part of the original Preliminary Plat of
the Sherri[I Acres Addition, this needs to be reflected
as such in the title block.
2. Include all platting information on the lot to the
west, Lot 2B, Block 1 including all adjacent
easements and property lines.
3. The phone number of the owner is different on the
site plan and landscape plan than it is on the Final
Plat, and the owner's name is spelled wrong on the
Final Plat.
4. Revise the franchise utility signature block to reflect
"TXU Electric Delivery" and a separate signature line
for TXU Gas.
5. Change AT&T Broadband to Comcast.