Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Irrigation Plan
(2)EST (2)EST lOG 10H IOQ lOq 0 15H 2' SLEEVE 15H 15H EST 8C 3/4' 15H #2 #2 //2 80 8Q( 2' SLEEVE 3/4' 8H( 1OH 1 OF 3~4' 15q10H 12TO lOG 1OH 15H ~ 150 0 1OH 15H 1OH 0 SST SST SST SST,J SST SST t5H 15H 15H (2)8Q (44)8H 15H 1/4' 15Q 15H t i-lo o 1OH 1OH lOG 1OH 1OH 15Q 4' SLEEVE 2' CONDUIT 0 1OH 8H 8H 1OH 0 0 ",,//2 #2 #2 ,, 3/4' #2 #2 4' SLEEVE 2' CONDUIT 2" IRRIGATION METER AND ¢' 2' DOUBLE CHECK DETECTOR CONTROLLER 3/4' %'-I~ 12Q 8H 8H '~.iSH 8H 8H 8H( 8H 1 1/4' 1' 12H lOG 1OH 8H 8H 8H 8H 8H 8HSTQ1 8F~ 0 0 0 0 O 0 ~ 3/4' .. 1OH 1OH, 1OH o, ¢o 0 0 . 0 0 1OH 1OH 1OH 1OH 8H 8H 8H 1 1/2' 1OH 1OH 1OH 0 0 0 o ~o 1OH~ 1OH "'-3/4' 12Q 12H 8H 8H 8H 8H (4)EST 11/2' (4)EST[]' ', o o o hit 1OH 10H4 d~H 1OH', 1OH '-3/4' 0 0 0 0 , 0 8H 8H 8H 8H 8H 4' SLEEVE 2' CONDUIT 3/4' 12Q ' 11/4' I EST~ /SST k'SST 'SST 12H 3~4; 12H 12H 1 1/4' - 1OH 1OH 1OH o, ,p__o "--3/4' 0 " 0 0 ' 1OH 1OH 1OH 1OH 0 0 1OH 1OH IOQ I //{2H T 3~4' -,..,,~ 1 1/4' EST 1: ' ~ I EST 8TO 8H 8H aH,, 8H 8H 8H 8H 8H ~ 150 150 m o ",*· ~, ,' o o o o o '-__~ 'SO 12H 8H 8H 8H ,SHI~,SH 8H 8H 8H 8H 8HSH t80/ 15H~ -- I T;-'t '&. ,' ,.:., -$ . / L~',,' 1' 314' · i, 3/4' / / / 2' SLEEVE "' ~ e/' ~ 15H / ~-~ 15Q H T l OH 15F /15t::'! :15F f ; 15F 0 I0 ¢~ ~, .-_ I ~, 0 1OH 1OH 1OH 1OH 1OH 1OH 1OH 1OH ~ / ' u ' O 0 0 0 0 O -0 0 .0 ' O O O O 'O O O O O O O O 1DH 1DH 1DH 1DH !OH 1DH 1DH 15H 15H 15H 15H 1OH 15Q 15H 15H 15H . . - 1 1/4' / 15H 15H '"1' 3~4' 15H 15H 15H 15© 15Q 15H 15H 12H 12H 12H 3/4' / 12H~/' 12H 12H t2H 1 1/2' 15H 33 I J 15H II 15H .. .... 3/4' 15H 15Q WATERPROOF WIRE CONNECTIONS 10" AMETEK VALVE BOX __ FINISH GRADE CONTROL WIRE COIL D AUTOMATIC VALVE MALE ADAPTERS INSTALLATION DETAIL ZONE VALVE ASSY. -- PVC LATERAL LINE o° ~ 00o0o~°]-~ 16AFDV DRAIN VALVE 00% %~ 0 o° ~ 0 ~ (1) CU. FT. GRAVEL 0 o %0% ( NOT SHOWN ON PLAN- INSTALL IN LOW AREAS AS NEEDED ) _(~ INSTALLATION DETAIL AUTO FILTER DRAIN RAINBIRD WALL-MOUNT --7 CONTROLLER / 48" ABOVE ~[ ~!~--2" CONTROL FINISH GRADE ~ ~ WIRiNC CONDUIT PO~R WIRING ~ ~ CONDUIT INSTALL PER RAINBIRD SPECIFICATIONS ii)INSTALLATION DETAIL WALL-MOUNT CONTROLLER -16 GAGE SHALL BE THE MINIMUM WIRE SIZE. TIE A LOOSE 20" LOOP IN ALL WIRING AT CHANGES OF DIRECTION GREATER ~TAPE AND BUNDLE THAN 30°. UNTIE ALL LOOPS AFTER ~24 VOLT WIRING CONNECTIONS HAVE BEEN MADE. ~AT 10' INTERVALS LATERAL CONTROL WIRES MAIN SUPPLY NOTES: BACKFILL MATERIAL SHALL BE FREE FROM ROCKS OR HEAVY UNSUITABLE SUBSTANCES WHICH COULD DAMAGE THE PIPE OR CREATE UNUSUAL SETTLING PROBLEMS. BACKFILLING SHALL BE DONE iN 6 INCH LAYERS AND TAMPED DOWN AFTER EACH LAYER IS PUT BACK TO PREVENT EXCESSIVE SETTLING. _~ INSTALI_ATION DETAIL MAINLINE, LATERAL AND WIRING 10" AMETEK VALVE BOX (2) MARLEX ST ELL TT 8" SCHSO NIPPLE MARLEX ST ELL TT ~ QUICK COUPLER VALVE · . S.S. CLAMPS ANGLE IRON SUPPORT ~--6" GRAVEL LAYER INSTALLATION DETAIL QUICK COUPLING VALVE ) iN STALLATION DETAIL DOUBLE CHECK VALVE ASSY. GENERAL IRRIGATION NOTES / ~-- SBE-O50 BARBED ELBOW 2 / W1/2' SWING PIPE ~___ FINISH GRADE MODEL 1812-PRS POP-UP SPRAY -PVC 1/2" THREADED TEE ~ PVC LATERAL LINE BE-050 BARBED ELBOW INSTALLATION DETAIL 4" POP-UP TURF SPRAY )INSTALLATION DETAIL 12" POP-UP SHRU3 SPRAY FREEZE SENSOR ~ RAIN SENSOR EXTERIOR WALL 3/4" CONDUIT INSTALL PER HUNTER SPECIFICATIONS INSTALLATION DETAIL CLIMATE SENSORS LEOEND DE~,Ct~IPTION M.Z~IUF.~,C TUI~.E I~ ~NT~OLLE~ 5Pt;~,:~¥ (51gE 5TiP ) 5Pl~.~"r' (~,lgE 6TIP ) 5P~T ~OTE CONTROL MAINLINE PIPING 5LEE~ PIPIN~ LATE~L PIPI~ 5TAT I<::;~N v,~,L v1E 51ZE ~'~>M (APPROX.) 20 0 20 40 CALL TEXAS ONE-CALL AT 1-800-544-8577 FOR INFORMATION ON THE LOCATION OF ALL UNDERGROUND UTILITIES. CONTACT PRIOR TO DIGGING. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE CAUSED TO THE UTILITIES (BOTH OVERHEAD AND BURIED) WHICH MAY OCCUR DUE TO HIS ACTION OR LACK OF ACTION ON THE PROJECT SITE DURING LANDSCAPE OR IRRIGATION INSTALLATION. CONTRACTOR SHALL SEEK THE ASSISTANCE OF LOCAL UTILITIES AND THE OWNER IN LOCATING THE UTILITIES PRIOR TO PERFORMING TRENCHING OPERATIONS IN ANY AREA. TRENCHING OPERATIONS SHALL NOT OCCUR UNDER THE DRIPLINE OF EXISTING TREES UNLESS ABSOLUTELY NECESSARY. IF CONDITIONS DO NOT ALLOW FOR TRENCHING TO BE DIRECTED AROUND DRIPLINE, THE TRENCHING SHALL BE DONE RADIAL WITH THE EXISTING TREE TRUNK. CONTRACTOR SHALL CAREFULLY VERIFY A MINIMUM RESIDUAL WATER PRESSURE OF 60PSI @ 57GPM ADJACENT TO THE WATER METER LOCATION. IF THE MINIMUM WATER PRESSURE IS LESS THAN 60 PSI, CONTRACTOR SHALL NOTIFY THE OWNER OF SUCH AND SHALL RECEIVE OWNER'S APPROVAL PRIOR TO BEGINNING INSTALLATION OPERATIONS. GENERAL CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF SLEEVES AS SHOWN ON THE DRAWING. EXTEND SLEEVES 2' BEYOND BACK OF CURB AND CAP UNTIL CONTRACTOR IS READY TO BEGIN INSTALLATION OF SYSTEM. STAKE LOCATION OF SLEEVE WITH T-POSTS AND FLAGS. GENERAL CONTRACTOR SHALL PROVIDE J-BOX (115VAC POWER) TO THE CONTROLLER LOCATION AND A 2" CONDUIT FROM THE CONTROLLER FOR VALVE WIRES. IRRIGATION CONTRACTOR SHALL HARDWiRE TO J-BOX. THE IRRIGATION DESIGN IS DIAGRAMMATIC. THE INTENT OF THE DRAWINGS IS TO SHOW THE GENERAL LAYOUT AND LOGIC OF THE SYSTEM. SCALED MEASUREMENTS MAY NOT BE ACCURATE. ACTUAL LOCATIONS AND QUANTITIES OF PIPE AND FITTINGS MAY VARY DUE TO FIELD ADJUSTMENTS FOR EXISTING AND NEW TREES AND OTHER OBSTRUCTIONS TO PROVIDE THE PROPER AND INTENDED COVERAGE. CONTRACTOR SHALL INSURE THAT THE IRRIGATION MAIN LINE AND VALVES ARE INSTALLED WITHIN THE PROERTY LINES. ANY LINES SHOWN OUTSIDE OF NORMAL INSTALLATION CORRIDORS ARE FOR PRESENTATION PURPOSES ONLY. CONTRAC. T~R SHALL CLOSELY FOLLOW THESE CONTRACT DRAWINGS, THE IRRIGATION SPECIFICATIONS, AND THE SPECIFIED RECOMMENDATIONS OF THE EQUIPMENT MANUFAcTuRERS TO INSURE PROPER INSTALLATION OF THE IRRIGATION ':~ ~ 'SYSTEM. CONTRACTOR SHALL IMMEDIATELY CONSULT WITH THE OWNER WHENEVER THERE APPEARS TO BE A CONFLICT ......... BETWEEN ANY OF THE ABOVE MENTIONED DOCUMENTS. O~ O~ OO 00~3 I I ('x~ Oq e I i t i i i i I i i I i IItl ! sc i~' 0L SHEET OF