Loading...
DRC commentsCO?PELL Project ID PD-04-0058 Address 717 Coppell Road CITY OF COPPELL COPPELL DRC REPORT Proiect Name PD-206-HO-R, Conoboy Addition Project Type Application Date Case Manager Proiect Description Re-Zoning PD 9/22/2004 Matt Steer zoning change request from HO-R (Historic Overlay-Retail) to PD-206-HO-R (Planned Development-206-Historic Overlay*Retail), to allow the conversion of a 3,000-square-foot residential structure to an office use on 0.4 of an acre of property Agency Building Inspection 1 of 2 Reviewed By Review Date Greg Jones 9/28/2004 Electric and Gas Jeff Curry 10/1/2004 Engineering Ken Griffin 9/30/2004 Fire Administration Tim Oates 10/1/2004 Parks and Recreation John Elias 9/29/2004 Planning Depar[ment Matt Steer 9/30/2004 Comments 1. Depending on the amount of renovations made to residence, there may be several items that will need to be addressed, including energy code compliance, Texas assessibility compliance and asbestos abatement. 2. Any new wiring will need to be installed in conduit or MC cable. 3. Existing electrical wiring will be acceptable unless altered. 4. New plumbing to be installed by new code provisions. 5. New mechanical and electrical must meet new energy conservation standards. Zoning Change Acceptable 1. Ensure positive drainage is maintained. 2. Use 18" minimum RCP for culverts. 3. A 17' drive width does not meet minimum subdivision standards. 4. Ensure adequate maneuvering room in parking area. No comments 1. Tree Removal Permit required prior to start of construction. Detail Site Plan 1. Add all Planned Development conditions to Site Plan. Exception required to the perimeter landscaping requirement due to drive located on the south side of the building and parking in rear. Exceptions to the setback requirements needed for the side yards located within the base zoning, Retail (30' required). Exception to front yard parking requirement. Exception required to the pavement width of the drive aisle to the rear parking. 2. Revise the zoning on this property and the adjacent properties. South is zoned Light Industrial, west is zoned Light Industrial and north is zoned Historic Overlay - Retail. The existing zoning on this property COFF'ELL Agency Reviewed By CITY OF COPPELL DRC REPORT Review Date COFFELL .~. Comments is Historic Overlay ~ Retail and is proposed to be changed to Planned Development 206 - Historic Overlay - Retail. 3. Show proposed lighting within the parking area. 4. Demonstrate how each of the parking spaces function regarding egress. 5. Remove "City of Coppell soccer fields" from all areas of plans. 6. Move the handicap space and ramp to the rear and ensure all requirements of the Texas Accessibility Standards are met. Landscape Plan 1. The Perimeter Landscaping requirement does not include the rear perimeter, and the perpendicular driveways and the asphalt drive can be subtracted from these calculations. 2. Change interior landscaping provided to read 547.5 square feet if 5,475 square feet is the correct square footage of parking area. An exception to the tree islands at the end of each row is required. Add to PD condition list on site plan. 3. Nonvehicular Landscaping required should show (size of lot (14,790) subtracted by building footprint (2,481)) X 15% = 1,846 square feet. Take 50% of this for the front yard requirement. 4. There are discrepancies between the paving shown on the site tabulation table and the interior landscaping calculations. Revise. 5. The site is deficient one tree in meeting the landscaping requirements of the Zoning Ordinance. Due to the unique situation of this lot and the inability to fit any additional trees, staff can recommend including this as a special condition within the Planned Development. 6. The hedge shown in the front yard is not required. 7. Add Lot # and Block letter to title block. Elevations 1. Please show a graphical representation of sign proposed with dimensions, colors and materials. Header is not shown within the letter submitted. 2. Indicate on sign plan that it will be hung perpendicular to the wall, if that is what is being proposed. 3. Include a sample of the proposed HDU Foam to be used on the sign (wooden sign is preferable for the area) and the limestone to be used in the renovation. 4. Please better represent the brick color on the color renderings of the building used as elevations. 5. Show existing elevations separately. CITY OF COPPELL 2nd DRC REPORT COFFELL ~ect ID PD-04 0058 Addres~ 7'7 CoppellRoad Project Name PD-206-HO R Conoboy Addition ProjAct Type A~pj~hcation Date Ca. se ManaRe_r Pr~ect Description Re-Zon;ng PD 922,2004 Ma. Steer zoning change request from HO-R (H~stor*c Overlay-Retad) to PD 206 HO-R {Planned Development 206 H~stonc Overlay Re alii o a ow the Conversion of a 3000 square-foot resdential structure to an Off'ce use on 0 4 of an acre of properly ~ency Er/g~neenng 1 of 1 Comments 1 Ensure positive drainage ~s maintained 2 A 1 7' drive width does not meet mrmmum subdivision standards 3 Ensure adequate maneuvenng room in parking area