Loading...
Site PlanACOUS./ACT A.D. ADJ. A.F.F. ASSR. AL. APPROX. ARCH. ASB. ASPH. MD. BITUM. BLDG. 8LK. BLKG. BM. BOT. B.T.B. CAB. C,B. CEM. GER. C.I. CLG. CLO. CIR. COL. CONC. CONSTR. CONT, CORR, CTSK, CNTR. CTR. DBL. DEPT. D.F. DET. DIA. DIM. DISP. DH. DR. DWR. DS. D.S.P. DWO. E EA. E.J. EL. ELEC. ELEV. EMER. ENCL. E.P. EQ. EQPT. E.W.C. (E) EX$ST. EXPO. EXP. EXT. F,A. F.B. F,D, FDN. FE. F,E.C. F.H.C. FIN. FL, FLASH, FLUOR, F.O.C. F,O,F, F.O.S, FPRF. FT. F.T, FTG. PURR. F&I FUT. GA. GALV. O.D. S.C. GL. GND. GR. GYP. N,B. H.C. HDWO. HDWE. H,M. HORIZ. HR. HGT. INSUL. INT. ABBREVIATIONS AND JAN. ANGLE JT. AT CENTERLINE KIT. DIAMETER PERPENDICULAR LAB. CHANNEL LAM. POUND OR NUMBER LAV. EXIST1NG LKR. LT. ACOUSTICAL TILE AREA DRAIN MAX. ADJUSTABLE B.C. ABOVE FINISH FLOOR MECH. AGGREGATE MEMB. ALUMINUM MTL. APPROXIMATE MFR. ARCHITECTURAL MH. ASBESTOS MIN. ASPHALT MIR. MISC. BOARD M.D. BITUMINOUS MTD. BUILDING MUL. BLOCK BLOCKING BEAM N. BOTTOM N.I.C. BACK TO BACK NO. or # NOM. CABINET N.T.S. CATCH BASIN CEMENT D.A. CERAMIC OBS. CAST IRON D.C. CEILING O.D. CLOSET OFF. CLEAR OPNG. COLUMN OPP. CONCRETE CONSmUCTtON p. CONTINUOUS PRCST. CORRIDOR PL. COUNTERSUNK P.LAM. COUNTER PLAS. CENTER PLYVCD. DOUBLE PR. DEPARTMENT PT. DRINKING FOUNTAIN P.T.D. DETAIL P.T.D/R DIAMETER DIMENSION DISPENSER Q.T. DOWN DOOR OPENING R DOOR RAD. DRAWER R.D. DOWNSPOUT REP. DRY STANDPIPE REFR. DRAWINGS RGTR. REINF. EXISTING REQ'D. EACH RESIL. EXPANSION JOINT RM. ELEVATION R.O. ELECTRICAL RWO. ELEVATOR R.W.L EMERGENCY ENCLOSURE ELECTRICAL PANEL EQUAL EQUIPMENT ELECTRIC H20 COOLER EXISTING EXIST1NG EXPOSED EXPANSION EXTERIOR FIRE ALARM FLAT BAR FLOOR DRA~N FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CAB FIRE HOSE CABINET FINISH FLOOR FLASHING FLUORESCENT FACE OF CONCRETE FACE OF FINISH FACE OF STUDS FIREPROOF FULL SIZE FOOT OR FEET FIRE TREATED FOOTING FURRING FURNISH ANO INSTALL FUTURE GAUGE GALVANIZED GRAB BAR GENERAL CONTRACTOR GLASs/GLAZING GROUND GRADE GYPSUM HOME BID HOLLOW CAB HARDWOOD HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT INSIDE DIAMETER (DIM.) INSuLATiON INTERIOR S,C, S.C,D. SCHED. S,D. SECT. SH. SHR, SHT. SIM. S,N,D. S,N,R. SNT, SPEC. SQ. S.S. S.SK. STA. STD. STL. STOR. STRL. SUSP. SYM. mD. T.B. T,C. TEL, TER, T,&G. THK. T.P. T,P.D. T,V, T.W, TYP. UNF. U,O,N, UR. V.C.T. VERT. VEST. V.I.F. w/o WT. JANITOR JOINT KITCHEN LABORATORY LAMINATE LAVATORY LOCKER UGHT MAXIMUM MEDICINE CABINET MECHANICAL MEMBRANE METAL MANUFACTURER MANHOLE MINIMUM MIRROR MISCELLANEOUS MASONRY OPENING MOUNTED MULLION NEW NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE OVERALL OBSCURE ON CENTER OUTSIDE DIAMETER (DIM.) OFFICE OPENING OPPOSITE PAINT PRECAST PLATE PLASTIC LAMINATE PLASTER PLYWOOD PAIR POINT PAPER TOWEL DISPENSER COMBINATION PAPER TOWel DISPENSER & RECEPTACLE QUARRY TiLE RELOCATE RADIUS ROOF DRAIN REFERENCE REFRIGERATOR REGISTER REINFORCED REQUIRED RESILIENY ROOM ROUGH dPENING REDWOOD RAIN WATER LEADER SOUTH SOLID CORE SEAT COVER DISPENSER SCHEDULE SOAP DISPENSER SECT1ON SHELF SHOWER SHEET SIMILAR SANITARY NAPKIN DISPENSE SANITARY NAPKIN RECEPTACLE SEALANT SPECIFICATiON SQUARE STAINLESS STEEL SERV1CE SINK STATION STANDARD STEEL STORAGE STRUCTURAL SUSPENDED SYMMETRICAL mEAD TOWEL BAR TOP OF CURB TELEPHONE TERRAZZO TONGUE AND GROOVE THICK TOP OF PAVEMENT TOILET PAPER DISPENSER TELEVISION TOP OF WALL TYPICAL UNFINISHED UNLESS OTHER~SE NOTED URINAL VlNYL COMPOSll~ON TiLE VERTICAL VES~BULE VERIFY IN FIELD WEST WITH WATER CLOSET WOOD WITHOUT WATERPROOF WAIN SCOT WIEIGHT 4 GENERAL NOTES R[YIEW OF CONTRACT DOCUMENTS AND F1ELD CONDITIONS BY CONTRACTOR THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACI DOCUMENTS WITH gAv-'H OTHER AND WITH AS-BUILT DRAWINGS PROVIDED BY THE OWNER AND SHALL AT ONCE REPORT TO THE ARCHITECT ERRORS, INCONSISTENCIES OR OMISSIONS. THE CONTRACTOR SHALL TAKE FIELD MEASUR~ENTS AND VERIFY F1ELD CONDITIONS. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR AND HAS CONTROL OVER CONSTRUCTION MEANS, METHOOS, TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK. LNTENT OF CONTRA(~T DOCUMENTS THE iNTENT OF THE CONTRACT DOCUMENTS iS TO ALLOW FOR THE PERFORMANCE O,F THE WORK. EVERY ITEM NECESSARILY REQ,UIRED MAY NOT BE SPECIFICALLY MENTIONED OR SHOWN. UNLESS EXPRESSLY STATED, ALL SYSTEMS AND EQUIPMENT SHALL BE COMPLETED AND APPROPRIATELY OPERABLE. FURNISH AND INSTALL ALL SPECIFIED AND APPROPRIATE ITEMS, AND ALL INCIDENTAL, ACCESSORY, AND OTHER ITEMS NOT SPECIFIED BUT REQUIRED FOR A COMPLETE AND FINISHED ASSEMBLY. DEFECTIVE WORK NO WORK DEFECTIVE IN WO,RKMANSHIP OR QUAUTY OR DEFICIENT iN ANY REQUIREMENTS OF THE CONTRACT DOCUMENTS wiLL BE ACCEPTABLE DESPITE THE ARCHITECFS FAILURE TO DISCOVER OR POINT OUT DEFECTS OR DEF1QENC1ES DURING CONSTRUCTION. DEFECTiVE WORK REVEALED WITHIN THE TIME REQUIRED BY GUARANTEES SHALL BE REPLACED BY WORK CONFORMING WITH THE iNTENT OF THE CONTRACT. NO PAYMENT, EITHER PARTIAL OR F1NAL SHALL BE CONSTRUED AS AN ACCEPTANCE OF DEFECTiVE WORK OR IMPROPER MATERIALS. FIREPROOf-lNG PATCH AND REPAIR ALL FIREPROOFING DAMAGE INCURRED DURING DEMO,tITION AND/OR CONSTRUCTIO.N. BY COOE ALL NEW PENETRATIONS GENERATED BY THE WORK DESCRIBED IN THESE DOCUMENTS. FIREPROOF AS REQ,UIRED AS BUILT DRAWINGS DURING THE COURSE OF CONSTRUCTION, ACTUAL LOCATIONS OF CONSTRUCTION ITEMS DENOTED iN THE CONSTRUCT10N DOCUMENTS SHALL BE iNDICATED TO SCALE, IN CONTRASTING INK ON THE DRAWINGS FOR ALL RUNS OF MECHANICAL S~RINKLER, PLUMBING AND ELECTRICAL WORK; INCLUDING SITE UTIliTIES AND CONCEALED DEViATiONS FROM THE DRAWINGS. UPON COMPLETION OF THE PROJECT THE ARCHITECT WILL PROVIDE THE CONTRACTOR W/ A REPRO,DUCIBLE SET OF ORIGINAL DOCUMENTS FOR "AS-BUILT" DOCUMENTATION. THIS SET SHALL BE CONSPICUOUSLY MARKED "AS-BUILTS" AND DELIVERED TO THE ARCHITECT. CONTRACTOR'S RES:PONSIBll ITY IT iS INTENDED THAT THE CONTRACTOR PROVIDE A COMPLETE J~ AND ANY OMISSIONS IN THESE NOTES OR IN THE OU~NE OF WORK SHALL NOT BE CONSTRUED AS REUEVING THE CONTRACTOR OF SUCH RESPONSIBIUT1ES IMPUED BY SCOPE OF WORK EXCEPT FOR ITEMS SPECIFICALLY NOTED. UNENFORCEABLE WORK SHOULD ANY PORTION OF THE CONTRACT DOCUMENTS PROVE TO BE, FOR WHATEVER REASONS, UNENFORCEABLE, SUCH UNENFORCEABIUTY SHALL NOT EXTEND TO THE REMAINDER OF THE CONTRACT NOR SHALL IT VOID ANY OTHER PROVISIONS OF THE CONTRACT. UEN~ THROUGHOUT THE DURATION OF THE PROJECT THE CONTRACTOR SHALL REFRAIN FROM ACTIONS THAT COULD LEAD TO THE FLUNG OF CLAIMS OF MEN BY SUBCONTRACTORS, SUPPUERS OF MATERIALS, LABOR, SERVICE, EQUIPMENT OR ANY OTHER INDIVIDUAL OR COMPANY SO ENTITLED UNDER GOVERNING LAWS AND REGULATiONS UNLESS REASONABLE AND JUSTIFIABLE CAUSE CAN BE SHOWN. APPROVAL FOR PAYMENT SHALL BE CONTINGENT UPON THE CONTRACTOR'S OBTAINING AND FURNISHING TO THE ARCHITECT SIGNED RELEASES FROM SUCH INDIVIDUALS OR COMPANIES. COORDINATION OF THE WORK THE CONTRACTOR IS RESPONSIBLE FOR REVIEW AND VERIRCATION OF CONTRACT DOCUMENTS, FIELD CONDITIONS AND DiMENSioNS FOR ACCURACY AND CONFIRMING THAT WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE ARE ANY QUESTIONS REGARDING THESE OR OTHER COORDINATION ISSUES, THE CONTRACTOR SHALL SUBMIT THEM, IN WRITING, TO THE ARCHITECT AND IS RESPONSIBLE FOR OBTAINING A WRITTEN CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTION, OR RELATED WORK. 10 11 WORK SHOULD COMPLY W/APPLICABLE COOES EXECUTE WORK iN ACCORDANCE W~TH ANY AND ALL APPLICABLE LOCAL, STATE, FEDERAL COOES, MANUFACTURER':$ RECOMMENDATIONS, TRADE AND RE~RENCE STANDARDS INCLUDING BUT NOT tJMITED TO: IBC, SEISMIC COOES, NEC, NFPA, UMC, LATEST ENFORCED EDITIONS, ASMC, DIMENSIONS DO NOT SCALE DRAWINGS; DIMENSIONS SHALL GOVERN. DETAILS SHALL GOVERN OVER PLANS AND ELEVATIONS. LARGE SCALE DETAILS SHALL GOVERN OVER SMALL SCALE DETAILS. WRITTEN S;PECIRCATIONS SHALL GOVERN OVER ALL 12 13 CLARIFICATIONS CLARIFY ALL DISCREPANCIES RELATivE TO CONSTRUCTiON DOCUMENTS, SPECIFICATIONS, AND FIELD CONDITIONS PRIOR TO SUBMITTING BIDS AND COMMENCING WORK. SUBSTITUTIONS THERE SHALL BE NO SUBSTITUTION OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED. WHERE THE TERM "OR EQUAL" iS USED, THE ARCHITECT ALONE SHALL DETERMINE EQUALITY BASED UPON INFORMATION SUBMITTED BY THE CONTRACTOR. 14 DRAWING DISTRIBUTION THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISTRIBUTION OF DRAWINGS TO ALL TRADES UNDER THEIR JIJRIS.DICTION. 15 CHANGES IN THE WORK DO NOT PROCEED WITH ANY WORK REQUIRING ADDITIONAL COMPENSATION BEYOND THE CONTRACT AMOUNT WITHOUT WRITTEN AUTHORIZATiON FROM THE OWNER. FA]LURE TO OBTAIN AUTHORIZATiON SHALL INVAUDATE ANY CLA]~ FOR EXTRA COMPENSATION. 16 EXISTiNG WORK ALL INSTALLED PLUMBING, MECHANICAL, AND ELECTRICAL EQULPMENT SHALL OPERATE QUIETLY AND FREE OF VIBRATION. 17 PUNCHUST UPON COMPLETiON OF THE '~,RK BY THE CONTRACTOR, THE CONTRACTOR SHALL NOTiFY THE ARCHITECT iN WRITiNG OF S:UCH COMPLETiON. THE ARCHITECT SHALL PREPARE A PUNCH-LIST OF CORRECTioNS, UNSATiSFACTORY, NON-COMPLIANT AND/OR iNCOMPLETE WORK. FINAL PAYMENT WILL BE CONTINGENT UPON THE COMPLETION OF THESE ITEMS UNDER THE TERMS OF THE OWNER/CONTRACTOR AGREEMENT. 18 MATERIALS ALL MATERIALS SHALL BE NEW, UNUSED, AND OF THE HIGHEST QUALITY iN EVERY RESPECT UNLESS OTHERWISE NOTED. MANUFACTURED MATERIALS AND EQUIPMENT SHALL BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTiONS, U.O.N. 19 2O INSURANCE THE CONTRACTOR AND SUBCONTRACTORS SHALL PURCHASE AND MAINTAIN CERTIFICATIONS OF iNSURANCE 'NTH RESPECT TO WORKERS COMPENSATION, PUBLIC lIABILITY AND PROPERTY DAMAGE FOR THE LIMITS AS REQUIRED BY LAW, IN ADDITiON TO THE TERMS OF THE OWINER'S CONTRACT, WHICH EVER IS GREATER THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS IN CONNECTION WITH THE WORK. EX]STING TENANTS COORDINATE ALL WORK WITH BUILDING OWNER SO AS NOT TO DISTURB OR CAUSE DAMAGE TO ANY TENANT iN THE BUILDING. AVOID CONFLICT AND iNTERFERENCE WITH NORMAL BUILDING OPERATIONS BY COMPLYING WITH THE BUILDiNG'S REGULATIONS REGARDING SCHEDULING AND USE O'F ELEVATORS AND LOADING DOCKS FOR DELIVERIES, HANDLING OF MATERIALS, EQUIPMENT, AND DEBRIS. 21 22 COORDINATION VERLFY IN THE FIELD, THAT NO CONFLICTS EXIST WHICH WO~JLD PROHIBIT THE LOCATiON OF ANY AND ALL MECHANICAL, TELEPHONE, ELECTRICAL LiGHTING, PLUMBING AND SPRINKLER EQUIPMENT (TO INCLUDE ALL REQUIRED PIPING, DUCTWORK AND CONDUIT) AND THAT ALL REQUIRED CLEARANCES FOR LNSTALLAT1ON AND MAINTENANCE OF ABOVE EQUIPMENT ARE PROVIDED. PROTECTION OF EXIST1NG WORK PROVIDE PROTECTION TO ALL EX]STING FINISHES iN ALL SPACES WITHIN OR ADJACENT TO THE SCOPE OF WORK AND THE TENANT'S SPACE. THE CONTRACTOR SHALL PATCH RERNISH TO AND REPAIR ANY DAMAGE CAUSED BY HIM OR HIS SUBCONTRACTORS. MATCH EXISTING ADJACENT F1NISH, OR AS NOTED HEREIN. 23 24 25 26 27 EXISTING DEFECTS CORRECT ANY DEFECTS FOUND iN EXISTING BUILDING CONSTRUCTION WHICH AFFECT THE SCOPE OF WORK. THIS INCLUDES BUT iS NOT lIMITED TO UNEVEN SURFACES AND FINISHES AT GYPSUM BOARD OR DAMAGED FIREPROOFING. PATCH AND REPAIR SURFACES TO MATCH ADJACENT, ADJOINING SURFAC:ES. "ITPICAL" OR "TYP." MEANS IDENTICAL FOR ALL SIMILAR CONDITIONS U.O.N. "SIMILAR" OR "SIM." MEANS COMPARABLE CHARACTERISTICS TO THE CONDITION NOTED. VERIFY DIMENSIONS AND ORIENTATION ON PLAN. "VERIFY" OR "VER." MEANS TO ASCERTAIN AND CONFIRM APPLICATION WITH ARC:HITECT. FURNITURE FURNITURE SHOWN iS FOR REFERENCE ONLY AND iNSTALLED BY OTHERS, U.O.N. 28 F1LE CABINETS, AS SHOWN ON DRAWINGS, ARE SUPPLIED BY OTHERS. COORDINATE FILE 'SIZE(S) W/FURNITURE INSTALLER FOR REQ'D CLEARANCES. 29 CLEANING PROVIDE STRICT CONTROL OF JOB CLEANING AND PREVENT DUST AND DEBRIS FROM MIGRATiNG FROM CONSTRUCTION AREA. 50 ADJACENT SPACES CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDUuNG OF ACCESS iNTO ADJACENT TENANT SPACES WITH THE BUILDING MANAGEMENT AS REQUIRED FOR PRICING AND EXECUTION OF THE WORK. 31 EXISTING CONDITION,~ CONTRACTOR SHALL THOROUGHLY EXAMINE THE PREMISES AND SHALL BASE HIS BID ON THE EXISTiNG C~DITIONS, NOTWITHSTANDING ANY INFORMATION SHOWN OR NOT INDICATED ON THE CONTRACT DOCUMENTS. 52 CONTRACT DOCUMENT~ AU_ CONTRACT DOCUMENTS ARE COMPLEMENTARY AND WHAT IS CALLED FOR BY ANY WILL BE AS BINDING AS IF CALLED FOR BY ALL ALL WORK SHOWN OR REFERRED TO ON ANY CONTRACT DOCUMENT SHALL BE PROVIDED AS THOUGH THEY ARE ON ALL RELATED DOCUMENTS. 55 CONTRACTOR RESPONSIBIUI'Y TO NOTiFY ARCHITECT IT SHALL BE THE RESPONSIBiliTY OF THE CONTRACTOR TO NOTIFY THE ARCHITECT OF ANY CONF1JCTS HEREIN - EITHER APPARENT OR OBVIOUS - PRIOR TO THE START OF NEW WORK ON THAT ITEM OR BEAR THE RESPONSIBILITY OF CORRECT, NO SUCH WORK AS DIRECTED BY THE ARCHITECT. DUPLICATION OF DOCUMENTS ALL DRAWINGS AND WRITTF_N MATERIAL HEREIN CONSTITUTE THE ORIGINAL AND UNPUBlISHED WORK OF THE ARCHITECT/OWNER AND THE SAME MAY NOT BE DUPlicATED, USED, OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT/OWNER. 35 EXISTING PENETRATION~ ALL PENETRATIONS TO THE FLOOR/CDUNG ASSEMBLY SHALL BE GROUTED SOtJD WITH A QUICK-SET CONG. FILLER. THE SLAB BETWEEN THE MECH. EQPT. ROOM AND THE TENANT SPACE SHALL BE ACOUSTICALLY SEALED AIRTIGHT WITH FIRE SEAL PER ARPlICAB:I F COOE. SYMBOLS OFFICE COLUMN GRiD LINE ROOM NAME AND NUMBER DRAW1NG NOTE CLOUD WITH REV1SION DELTA A DETAIL REFERENCE DETAIL REFERENCE W1TH ARROW DETAIL FLAG ELEVATION REFERENCE T T ALIGN DIMENSIONS TO FINISH FACE DIMENSION TO CENTERLINE DATUM POINT CODE REFERENCES BUILDING PLUMBING MECHANICAL ELECTRICAL ENERGY ACCESSIBILITY 2000 INTERNATIONAL BUILDING CODE W/ LOCAL AMENDMENTS 2000 INTERNATIONAL PLUMBING CODES W/ LOCAL AMENDMENTS 2000 INTERNATIONAL MECHANICAL CODES W/ LOCAL AMENDMENTS 2002 NATIONAL ELECTRICAL CODE-NFPA W/ LOCAL AMENDMENTS 2000 INTERNATIONAL ENERGY CONSERVATION CODE W/ 2001 SUPPLEMENT AMENDMENTS TAS - TEXAS ACCESSIBILITY STANDARDS HAZARDOUS MATERIALS NOTES O~ER ACKO'a!_EOGES THAT iNTERIOR ARC:HITECTS SHALL HAVE NO RESPONSIBILITY FOR THE DISCOVERY, RE~OVAL, PRESENCE HANDLING, DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS SUBSTANCES, MATERIALS, WASTES IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT UMITED TO ASBESTOS, ASBESTOS PROOUCTS, PCB, OR OTHER TOXIC SUBSTANCES. THE OWNER AC:KNOWLEDGES THAT IT ACCEPIS RES?O,NS/BILITW FOR NOTIFYING THE APPROPRIATE FEDERAL STATE AND LOCAL GOVERNING AGENCIES FOR ANY DEMO(J~ION, CONSTRUCTiON, OR REPAIR W~3RK. ANY QUESTIONS THAT ARISE RELATED TO ASBESTOS SHALL BE REFERRED TO THE OWNER FOR RES~UTiON. INTERIOR ARCHITECTS SHALL NOT B:E REQUIRED TO DO ANY WORK NOR RENDER ANY OP1NIONS RELATED TO ASBESTOS. THE OWNER SHALL RETA]N AN INDEPENDENT CONSULTANT WHO IS TRAINED AND EXPERIENCED IN IDENTIFICATION ANO SURVEY OF EXISTING SITES PRIOR TO START OF O~OUTiON CONSTRUCTION. ALL CONTRACTORS AND SUBC~TRACTORS SHALL REPORT THE PRESENCE OF ANY MATERIAL OR ASSEMBLY SUSPECTED TO CONTAIN ASBESTOS UPON DISCOVERY. THE WORK SHALL BE CARRIED OUT PER THE CONSULTANTS' RECOMMENDATONS. PROJECT INFORMATION BUILDING ADDRESS: SCOPE OF WORK: AVAYA 1111 FREEPORT PARKWAY COPPELL TX 75.019 RENOVATION OF TENANT SPACE (APPROXIMATELY 8,571 S.F.) SQUARE FOOTAGE: APPROXIMAIELY 2,333 S.F. OCCUPANCY TYPE: FiRE PROTECTION: SPRINKLERED CONSTRUCT]ON TYPE: CONCRETE STRUCTURE NUMBER OF STORIES: 2 SHEET INDEX AN-1 AN-2 AO.O A1 .O AN.7 GENERAL INFORMATION GENERAL NOTES DEMOLITION PLAN DEMOLITION PLAN ELEVATIONS PROJECT DIRECTORY CUENT: AVAYA 211 MOUNT AIRY ROAD BASKING RIDGE, NJ 07920 PHONE: (908) 953-3628 FAX: (908) 953-5587 CONTACT: CHARLES LESTER cleste,rO~:Y~y~ corn ARCHITECT: INTERIOR ARCHITECTS, INC. 5252 MCKINNEY AVE. SUITE 970 DALLAS, TX 75204 214.740.1922 214.740.1955 (FAX) CONTACT: TIM TERRY LterryQ(nterio,rorch itects.com ARCHITECT OF RECORO: TIM TERRY L terr:~nterio¢orchitects, corn Texos Registr~tio~ ~ 7539 PROJECT MANAGER: PRECEPT BUILDERS 1909 WOO,DALL ROOOCRS FTFY DALLAS, TX 75201 214.953.510'0 214.955.0701 CONTACT: STEVE FRENCH sfre.n ch ~receptbuilders. co,m MEP ENGINEER: PHILliPS & BACON ONE W~ST THIRD ST. STE. 1115 TULSA, OK 74103 918.584.0102 9t8.582.2819 (FAX) CONTACT: CHRISTOPHER HARWID_L H~r~eH~hillboc.com CONSULTANT: DATASTAR USA 6501WINDCREST DR SUITE 5O0 PIANO, TX 75024 214.291.2000 214,291.0020 (FAX) CONTACT: BOYD JOHNS, RCDD boyd.johns~at~starus~.corn KEY PLAN N Date SEWER LI AVl 1111 FREEPO COPPELL 1, DESIGN REVIEW Issue Descrfption 8MR T ,do 065106.00 TFr~ GENER INFORi AN-