Loading...
DRC commentsCOPPELL Proiect ID ~D-0§-000~ Address State Highway t2t CITY OF COPPELL DRC REPORT Proiect N~me COPPELL PD-199-HCR2, Vista Point II (Bank of Texas) ProlectType Appllca~on Date Case Manaaer ProiectDescHotion Re-Zoning PD 2/15/2005 Marcie Diamond Zoning change request from PD-199-HC (Planned Development-199-Highway C~mmercial to PD-199-HC-R2 (Planned Development-199-Highway Commercial-Revision 2) to allow the development of~an'~l~- approximate 5,585 square foot bank facility, with drive through lanes. Agency Building Inspection 1 of 1 Reviewed By Review Date Greg Jones 2/22/2005 Electric and Gas Jeff Curry 2/24/2005 Engineering Ken Griffin 2/24/2005 Fire Administration Tim Oates 2/24/2005 Parks and Recreation Planning Department John Elias 2/22/2005 Marcie Diamond 2/23/2005 1. No floc~r plan information submitted for review. Unable to!make comments. Zoning Cl~ange Acceptable. See comr~ents under Replat / Project ID# RP-05-0002. 1, Fire hy(~rants shall be located every 300'. 2. Proposed FDC line shall not run under building. 3. Proposed Fire Hydrant along Mac. to be relocated to S. drive. 4. Proposed Fire Hydrant and FDC must be 3'-6' from back of c~rb. 5. Fire sprinkler room shall be directly accessible from the exterior. No comm SITE PLA 1. Delete all easem 2. The are typic; 3. The ligl coordinat, 4. Indical 5. Drivew be appro~ 6. Includ~ side of IV ;nts he utility lines from the site plan, but retain .~nts, as applicable. LJ transformer, needs to be screened. Shrubs Ily used as a screening devise. ~t standards (parking lot lights) need to be ~for all developments of within this PD. ~ R.O.W. for Lake Vista Drive. ~y location and deceleration lane needs to ed by the City of Lewisville. the existing zoning designations on the east )cArthur Blvd. LANDSCAPE PLAN 1. The TX~.J transformer, needs to be screened. Shrubs are typically used as a screening devise. 2. Revise~the Landscape Planting Schedule, under descriptioN to indicate existing trees as existing instead of proposed. ELEVATIONS 1. The m~terials and colors of the exterior finishes and the standing seam metal roof need to be in complian(~e with the color board and materials approvedlfor this PD. 2. Cedar ~rellis not appropriate. COPPELL ~roioct ID R~-0§-0002 Address State Hi0hw*¥ 12~ CITY OF COPPELL DRC REPORT Project Nqme COPPELL Vista Point II (Bank of Texas) Proiect TvDe Aoolication Date Case Maoaoer Prolect Descriotion Replat 2/15~2005 Marcie Diamond to revise the location of the fire lanes to allow the development of an approximate 5,585 square foot bank facility, with ddve through lanes. Building Inspection Electric and Gas 1 of 2 Reviewed By Review Date Greg Jones 212212005 Jeff Curry 2/24/2005 Engineering Ken Griffin 2/24/2005 1. No comments made on replat. Plat Unacceptable, please contact Larry Redick at 972-323-8917 to discuss easement requirements. Also, please change the signature block to read TXU Electric Delivery Company. Plat: 1. If the 12" water line along MacArthur is as shown on the site plan, a 20' utility easement centered on the water line in needed. 2. Show the Coppell/LewisviIle City Limits on this sheet. Site Plan: 1. The monument sign must be moved out of the proposed 20' utility easement required for the 12" water line, 2. New sidewalk shall be 5'-0" wide instead of 4'-0". 3. Show tlhe curb line for Lake Vista Drive on this drawing. Does the proposed south driveway align with Lake vista? 4. Is a left!turn lane proposed for the south driveway? 5. Whether a car or truck can safely make a left turn from the South proposed driveway is unclear due to the northern median nose encroaching into the radius of the driveWay. 6. It's my understanding that the City of Lewisville may require deceleration lanes adjacent to this site. Has the site plan been revised to reflect all of Lewisville's concerns, issues and/or requirements? Utility Plal~: 1. The water line stub out shown to end under the dumpster must be extended outside the limits of concrete. 2. Show existing storm sewer piping on the drawing. 3. Design:the private fire line so there is no dead end. 4. The proposed location of the fire vault is too close to tree ET-8. 5. Tap the 12" water line only once and run both irrigation and domestic water off that tap. 6. Provide proof of permission from adjacent property owners to work offsite and to install water line stub outs and fire hydrants. COFFELL Agency Fire Administration Parks and Recreation Planning Department Reviewed By Tim Oates John Elias Marcie Diamond CITY OF COPPELL DRC REPORT Review Date COFFELL Comments 7. Is the 8" Sanitary Sewer Line "SS-I" public? 8. Explain~the reasoning for the configuration of the water line at the northwest corner of the property. Grading I~lan: 1. Provide more elevation information along the eastern pertion of the property so that flow may be determined. All water must be picked up on site. Erosion Control Plan: 1. Providq inlet protection at all inlets on the site. 2. Note that all erosion control notes and details shall conform te TCEQ regulations. Erosion COntrol Details: 1. StabilizEd Construction Entrance Detail shall match corresponding Notes. (Is the minimum thickness 6" or 8"?) - The offslte utility and paving work to support this project needs to be submitted prior to receiving any permits for the development. 2/24/2005 Utility: 1. Fire Hydrants required every 300' for commerci~bl sites. 2. Relocate fire hydrant on Mac. to south driveway. 3. Fire hyarants and FDC must be 3'-6' from fire lane. Plat: 1. Er~tire Fire Lane/Mutual Access easement must be installed prior to building construction. 2/22/2005 2/23/2005 No comments 1. TXU's Current name is TXU Electric Delivery Company~ revise proposed easements and signature block accOrdingly. 2. Change the Title of the plat from Final Plat to Replat. MEMORANDUM To: Marcie Diamond From: Jeff Curry Date: February 24, 2005 Subject: March DRC PD-199R2-ttC, Vista Point II, Lot 5, Block A (Bank o! Texa~) - Zoning Change Acceptable Vista Point Il, Lot 5, Block A Replat - Plat Unacceptable, plqase contact Larry Redick at 972-323-8917 to discuss electric easement requirements. Al~o, please change thc signature block to read TXU Electric Delivery Company. S,1211R, Service Star - Zoning Change Acceptable. please contact Larry Redick at 972-323-8917 to discuss electric service requirements. PD-97R3-R, Corners of Coppell - Zoning Change Acceptable, please contact Larry Redick at 972-323-8917 to discuss electric service requirementS. Wynnpage Plaza North, Lot 2, Block B, Site Plan - Site Pla0 Acceptable Wynnpage Plaza North, Lot 2, Block B, Final Plat - Plat Unacceptable, please contact Larry Redick to discuss electric easement reqairements. Also,iplease change the signature block to read TXU Electric Delivery Company and add a line for Atmos Energy. Beltline Trade Center, Lot 1, Block 1, Site Plan - Site Plan Acceptable Beltline Trade Center, Lot l, Block 1, Minor Plat - plat Unacceptable, please contact Jeff Curry at 972-570-4126 to discuss electric easement'requiflements. Park West Commerce Center, Lot 2R-3, Block 2, Site Plat~ - Site Plan Acceptable Park West Commerce Center, Lot 2R-3, Block 2, Replat'-!Plat Unacceptable. please contact Jeff Curry at 972-570-4126 to discuss electric easement reqmtements.