Prelim. Water & Waste WaterN
0 30 60 9,0 120 180
SCALE ~N FEET
INSTALL:
2-4.5° BENDS
1-10"X8" TEE
2-10" GATE VALVES
1-8" GATE VALVE
CONNECT PROPOSED 10" WATER LINE
TO EXISTING 12" WATER LINE
INSTALL:
1-10" DETECTOR CHECK
1-10" GATE VALVE
1-12"X10" TEE
25'X25' / .'
EASEMENT "
INSTALL:
1-8"X6" TEE
1-6I' GATE VALVE
1-FIRE HYDRANT
10 LF 6" WATER LINE
J
20' DRAINAGE EASEMENT
VOL, 4031, PG. 1093
INSTALL:
1-4.5° BEND
1-11,25° BEND
INSTALL:
1-12"X2" TEE
1-2" DOMESTIC METER
1-2" GATE VALVE
120 LF 2" WATER LINE
· INSTALL:
1-10"X6" TEE
1-10" GATE VALVE
1-6" GATE VALVE
1-90° BEND
1-FIRE HYDRANT
20 LF 6" WATER LINE
/
, / /
/
INSTALL:
1-8"X6" TEE
1-6" GATE VALVE
1-FIRE HYDRANT
20 LF 6" WATER LINE
INSTALL:
1-12"X2" TEE
1-2" DOMESTIC METER
1-2" GATE VALVE
145 LF 2" WATER LINE
N52'35'~' 'E
%
/
/
/
/
/
/
/
INSTALL:
6'SS CLEANOUT
FL=445.60
INSTALL:
6ISS CLEANOUT
FL:446.23
INSTALL:55 LF 6ISS "_
CONNECT TO NEW BLDG.
101 WATER
/
/
20'x20' ELECTRIC
EASEMENT
N89'OS'26'W
INSTALL:
1-10"X8" TEE
1-10" GATE VALVE
10 LF 8Il WATER LINE
CONNECT TO NEW BLOG.
INSTALL:
1-8"X8" TEE
3-8" GATE VALVE ." "
/
/
/ /
/
/
/
/
/
/
.://
//
INSTALL: 20 LF 6'SS
CONNECT TO NEW BLDG.
\
/
INSTALL:
1-10"X8" TEE
1-8I' GATE VALVE
55 LF 8" WATER LINE
CONN. TO NEW BLDG,
'x
x,
,/' "* //
1142.02'
INSTALL:
1-45° BEND
1-11.25° BEND
END AND PLUG
10" WATER LINE
INSTALL:
1-10"X6" TEE
1-10" GATE VALVE
1-6" GATE VALVE
1-FIRE HYDRANT
4.0 LF 6" WATER LINE
CONSTRUCT STD.
4'DIA. MANHOLE
FL 6IIN:443.38
FL 8IOUT:443,38
INSTALL 60 LF
6'SS STUBOUT
--END AND PLUG
INSTALL:
1-10"X6" TEE
1-6" GATE VALVE
1-FIRE HYDRANT
205 LF 6" WATER LINE
INSTALL:
6'SS CLEANOUT
FL=444.90
INSTALL:
8'SS CLEANOUT
FL:443.01
INSTALL:34 LF 6ISS
CONNECT TO NEW BLDG,
INSTALL:
8'SS CLEANOUT
FL:442,34
15' ELECTRIC AND -
GAS INE EASEMENT
INSTALL:
1-10"X6" TEE
1-6" GATE VALVE
1-FIRE HYDRANT
15 LF 6" WATER LINE
INSTALL:
1-8"X8" TEE
1-8'l GATE VALVE
150 LF 8" WATER LINE
CONNECT TO NEW BLDG.
NOTE:
END AND PLUG WATER
AND SEWER 10' PAST
LIMITS OF CONSTRUCTION.
END AND PLUG
10" WATER LINE
INSTALL:
1-10"X8" CROSS
2-10" GATE VALVES
1-8" GATE VALVE
INSTALL:
1-8"X6" TEE
1-8" GATE VALVE
1-6'l GATE VALVE
1-FIRE HYDRANT
10 LF 6" WATER LINE
INSTALL:
1-8"X2" TEE
1-2" DOMESTIC METER
1-2'l GATE VALVE
115 LF 2" WATER LINE
INSTALL 60 LF
6'SS STUBOUT
END AND PLUG
INSTALL:
2-45° 8"BENDS
EXIST. WATER
EASEMENT
CONNECT PROPOSED 8" WATER LINE
TO EXISTING 8" WATER LINE
INSTALL:
1-8" DETECTOR CHECK
1-8" GATE VALVE
1-8"X8" TEE
,35 LF 8" WATER LINE
CONSTRUCT STD.
4' DIA. MANHOLE
FL 15' IN:441.61
FL 15' 0UT=44t.61
RIM=TO GRADE
INSTALL:
f1-8"X6" TEE
1-6" GATE VALVE
l-FIRE HYDRANT
J
LLI
o
o
o
Project No: A¥O ~' 22223
Date Descr pt;on
D r a',",, n by: JLS
Checked by BDL
Sheet Title
PRELIMINARY WATER
AND WASTEwTER
C-3
Sheet Number
J~\220008\22223\dgn\cfvli\223PRE-WWl.d~n 6/7/2004 2:07~34 PM
St ~n<~ord~lvll
0 30 60 90 120 I80
SCALE ~hl FEET
15'
20' UT LITY
EASEMENt' .
- -~ , __ CItY OF LEWISVILLE
) WATER MAIN
~ ~ -- WATER EASEMENT
t _[__ ~F NEW 10' DETECTOR CHECK
REST.
[STRUCTIOIN
SER~tCE
<
(5o )
15' UTILITY EASEMENT
Date
LLI
AVO # 22223
'
i Descr:pTon
Drawn by:
Checked bi BDL
Sheet Tit,e
PRELIMINARY WATER
AND WASTEwATER
C-4
Sheet ,Number
J:\22000s\22223\dg,n\ctvfl\223PRE_ffW2.d,;n
S t<:md,::r cifvfi
617/2004 2:07~46 PM