Prelim. Water & Waste WaterN 0 30 60 9,0 120 180 SCALE ~N FEET INSTALL: 2-4.5° BENDS 1-10"X8" TEE 2-10" GATE VALVES 1-8" GATE VALVE CONNECT PROPOSED 10" WATER LINE TO EXISTING 12" WATER LINE INSTALL: 1-10" DETECTOR CHECK 1-10" GATE VALVE 1-12"X10" TEE 25'X25' / .' EASEMENT " INSTALL: 1-8"X6" TEE 1-6I' GATE VALVE 1-FIRE HYDRANT 10 LF 6" WATER LINE J 20' DRAINAGE EASEMENT VOL, 4031, PG. 1093 INSTALL: 1-4.5° BEND 1-11,25° BEND INSTALL: 1-12"X2" TEE 1-2" DOMESTIC METER 1-2" GATE VALVE 120 LF 2" WATER LINE · INSTALL: 1-10"X6" TEE 1-10" GATE VALVE 1-6" GATE VALVE 1-90° BEND 1-FIRE HYDRANT 20 LF 6" WATER LINE / , / / / INSTALL: 1-8"X6" TEE 1-6" GATE VALVE 1-FIRE HYDRANT 20 LF 6" WATER LINE INSTALL: 1-12"X2" TEE 1-2" DOMESTIC METER 1-2" GATE VALVE 145 LF 2" WATER LINE N52'35'~' 'E % / / / / / / / INSTALL: 6'SS CLEANOUT FL=445.60 INSTALL: 6ISS CLEANOUT FL:446.23 INSTALL:55 LF 6ISS "_ CONNECT TO NEW BLDG. 101 WATER / / 20'x20' ELECTRIC EASEMENT N89'OS'26'W INSTALL: 1-10"X8" TEE 1-10" GATE VALVE 10 LF 8Il WATER LINE CONNECT TO NEW BLOG. INSTALL: 1-8"X8" TEE 3-8" GATE VALVE ." " / / / / / / / / / / .:// // INSTALL: 20 LF 6'SS CONNECT TO NEW BLDG. \ / INSTALL: 1-10"X8" TEE 1-8I' GATE VALVE 55 LF 8" WATER LINE CONN. TO NEW BLDG, 'x x, ,/' "* // 1142.02' INSTALL: 1-45° BEND 1-11.25° BEND END AND PLUG 10" WATER LINE INSTALL: 1-10"X6" TEE 1-10" GATE VALVE 1-6" GATE VALVE 1-FIRE HYDRANT 4.0 LF 6" WATER LINE CONSTRUCT STD. 4'DIA. MANHOLE FL 6IIN:443.38 FL 8IOUT:443,38 INSTALL 60 LF 6'SS STUBOUT --END AND PLUG INSTALL: 1-10"X6" TEE 1-6" GATE VALVE 1-FIRE HYDRANT 205 LF 6" WATER LINE INSTALL: 6'SS CLEANOUT FL=444.90 INSTALL: 8'SS CLEANOUT FL:443.01 INSTALL:34 LF 6ISS CONNECT TO NEW BLDG, INSTALL: 8'SS CLEANOUT FL:442,34 15' ELECTRIC AND - GAS INE EASEMENT INSTALL: 1-10"X6" TEE 1-6" GATE VALVE 1-FIRE HYDRANT 15 LF 6" WATER LINE INSTALL: 1-8"X8" TEE 1-8'l GATE VALVE 150 LF 8" WATER LINE CONNECT TO NEW BLDG. NOTE: END AND PLUG WATER AND SEWER 10' PAST LIMITS OF CONSTRUCTION. END AND PLUG 10" WATER LINE INSTALL: 1-10"X8" CROSS 2-10" GATE VALVES 1-8" GATE VALVE INSTALL: 1-8"X6" TEE 1-8" GATE VALVE 1-6'l GATE VALVE 1-FIRE HYDRANT 10 LF 6" WATER LINE INSTALL: 1-8"X2" TEE 1-2" DOMESTIC METER 1-2'l GATE VALVE 115 LF 2" WATER LINE INSTALL 60 LF 6'SS STUBOUT END AND PLUG INSTALL: 2-45° 8"BENDS EXIST. WATER EASEMENT CONNECT PROPOSED 8" WATER LINE TO EXISTING 8" WATER LINE INSTALL: 1-8" DETECTOR CHECK 1-8" GATE VALVE 1-8"X8" TEE ,35 LF 8" WATER LINE CONSTRUCT STD. 4' DIA. MANHOLE FL 15' IN:441.61 FL 15' 0UT=44t.61 RIM=TO GRADE INSTALL: f1-8"X6" TEE 1-6" GATE VALVE l-FIRE HYDRANT J LLI o o o Project No: A¥O ~' 22223 Date Descr pt;on D r a',",, n by: JLS Checked by BDL Sheet Title PRELIMINARY WATER AND WASTEwTER C-3 Sheet Number J~\220008\22223\dgn\cfvli\223PRE-WWl.d~n 6/7/2004 2:07~34 PM St ~n<~ord~lvll 0 30 60 90 120 I80 SCALE ~hl FEET 15' 20' UT LITY EASEMENt' . - -~ , __ CItY OF LEWISVILLE ) WATER MAIN ~ ~ -- WATER EASEMENT t _[__ ~F NEW 10' DETECTOR CHECK REST. [STRUCTIOIN SER~tCE < (5o ) 15' UTILITY EASEMENT Date LLI AVO # 22223 ' i Descr:pTon Drawn by: Checked bi BDL Sheet Tit,e PRELIMINARY WATER AND WASTEwATER C-4 Sheet ,Number J:\22000s\22223\dg,n\ctvfl\223PRE_ffW2.d,;n S t<:md,::r cifvfi 617/2004 2:07~46 PM