Loading...
Water & Sanitary Sewer PlanS~ / / / I -4 J 6' ,",: ,3~ S C~C R--38.00' T-37.75' CH'-S 46'04'22' W SS :ESS ESMT. ) C~AT~ ,,' ', ~ 38' RCP~ GRATE ~LET STA 0+00 UNE BEGIN 8' SANI SEWER SERVICE REMO~'E CAP, INSTALL 1-SANITARY SE~rr_R ACCESS DEVICE AS PER CiTY OF COPPELL STANDARDS FL 8'=508.10 _ --..... ~TAII 6" ;ANI SEWER N 00"~3'14,' E STA 2+30.0 LINE INSTALL: 1-6' 90' HGRZ BEND 1 -CLEAN-OUT FL 6'=512.50 LOT 2.R, BLOCK 2 PARK WEST OMMERCE CENTER N 0~'~'14'~ E 728.56' STA 1+78.0 UNE INSTALL: 1-6' 90' HO~Z BEND 1-CLEAN-OUT FL 6'=512.90 LS '~a ICY INISTALL SANI SEWER 89'06'4-6' E 15.50' STA O+OC UNE BEGIN 8" SANI SEWER SERVICE REMOVE: CAP, INSTALL -SANITARY SEWER ACCESS DEVICE AS PER CITY OF COPPED_ STANDARDS q_ 8"=510.90 INSTALL 1-3' WATER SERVICE i'x2' REDUCER 1-2' WATER METER W~)OUBL~' C~ECK (DIOMESTIC) -3'x2' REDUCER ,INSTALL 3" WATER SERVICE TO A POINT 3' OFF BLDG END & CAP INSTALL: 1-8'x6' TEE 1-6' VALVE 1-RRE HYDRANT STA 0+38.0 UNE END 8' SANITARY SEWER BEGIN 6' SANIRATY SEWER INSTAl l: 1-STD 4; DtA NANHOII:' W/CHIMNEY SEAL BEGIN 6' SANI SERVICE (SE) INSTALL DOUBLE CLEAN-OUT 3' OFF BLDG, END & CAP FL 0 BLDG=514.00 FL 8' OUT=508.50 6' IN =508.70 INSTALD 1-8'x6' TEE 1-6' VALVE 1-FiRE HYDRANT STA 2+59.5 UNE "SS-l' END & CAP 6" SANI SEWER SERV1CE AT A POINT 3' OFF BUILDING INSTALl: 1-DOUBLE =CLEAN-OUT Fl. 0 BLDG 514.00 PROPOSED FIRE DEPARTMENT CONNECTION SHOWN FOR REFERENCE ONLY, REFER TO RRE PROTECTION PLANS FOR DETAIl_ F1NISH FLOOR F1 FVATION=519.5.0 INSTALL 8' WATER, STA 2+07.5 UNE 'SS-2' END & CAP 6' SANI SEWER SERVICE AT A POINT 3' OFF BUlL.DING INSTALL: 1-DOUBLE CLEAN-OUT FL 0 BLDG=514.00 1-8%6' TEE 1-6' VALVE 1-FIRE HYDRANT STA 0+42,0 UNE END 8' SANITARY SEWER BEGIN 6' SANIRATY SEWER INSTALL: 1-STD ,~' DIA MANHOLE W/CHIMNEY SEAL BEGIN 6' SANI SERVICE (SE) INSTALL DOUBLE CLEAN-OUT 3' OFF BLDG, END & CAP FL {3 BLDG=51~.O0 FL 8" 0'UT=511.30 FL 6" IN =5tl,50 INSTALL: 1-8'x6' TEE 1-6' VALVE 1-FIRE HYDRANT 0 25 50 lOO 150 GRAPHIC SCALE IN FEET F~'<> FIRE HYDRANT PP, POWER POLE I L$ ~-I %t- UGHT STANDARD '~1 ~o WATER METER w'vo WATER VALVE coo CLEANOUT UH O~_] MANHOLE GU <S OAS METER .... PROPERTY UNE 20'x35' WATER EASEMENT CONNECT TO EX. 8' WATID~ UNE INSTAll-' 1-8'x8' TAPPING 1-8" VALVE 1-8' DETECTOR CHECK W/ VAULT iTALL 8' INSTAll_' 4--6' DIA. STEEL GUARD POSTS SPACED A MIN. APART. REFERENCE OTY OF COPPELL STANDARD DETAIL INSTALL 8" WATER iNSTALl.; '~ 1-8' CROSS 2-8' VALVES INSTALL 2-8' FIRE PROTECTION SERVICES TO A POINT 3' OFF BUILDINGS, END & CAP TALL: 1-3' WATER SERV1CE REDUCER 1-2' WA~ W/D~B~ CHE~ (D~ES~C)~ 1-3'x2' REDUC~ tNSTA~ 3' WA~ ~ TO A PONT 3' O~ STA 4+42.5 UNE 'SS-3" END &~ CAP 6' SANI SEWER SERVICE AT A POINT 3' OFF BUILDING INSTAll-' 1-DOUBLE CLEAN-OUT FL 0 BLDG=513.50 STA 2+50.0 UNE INSTALL~ 1-6'x6' WYE CONNECTION 1-6' SANI SEWER SERVICE INSTALL DOUBLE CLEAN-OUT 3' OFF BLDO, END ~ CAP FL 0 BLDG=,513.50 FL 6' 0 WYE=509.00 RNISH FLOOR ELEVATION= 519.00 STA 0+67.0 UNE =STA 0+00 UNE 'SS-4" END 8' SANITARY SEWER BEGIN 2-6' SANIRATY SEWF_R INSTALL: 1-sm ~' D~^ MANHOLE W/C.H, IM NEY SEAL FL 8 OUT=505.10 FL 6" IN =505.30 STA 1+52.0 UNE 'SS-4' INSTALL: 1-6'x6' WYE CONNECTION 1-6" SANI SEW~ SERVICE INSTALL DOUBLE CLEAN-OUT 3' OFF BLDO, END ,~ CAP FL 0 BLDG=513.50 FL 6' 0 WYE=508.30 STA 3+4-4.5 UNE 'SS-4' END & CAP 6' SANI SEWER SERVICE AT A POINT 3' OFF BUILDING INSTALL: 1-DOUBLE CLEAN-OUT FL 0 BLDG=,513.50 INSTALL: 1-8'x6' TEE 1-6' '/ALVE 1-RRE '.';YDRANT I 15'x50' tNSTAL~ 1-2' WATER SERVICE 1-2' WATE. R METER (IRRIGATION) L$ 'r~ · [] TS~ jU'N,CllC~ nBOX PP 50' LS. GAS (VOL 157'7, PG. 8) ,(VOL 2017, PG. 69) VOL. 71167, PO. 1303) VOL g0097, PG. 114-4) 6" SANI SEWER' --- '-"e~~ i_ _.. --- STALL 6" SANI STA 44-12.5 UNE INSTAll-' 1-6' 90' HORZ BIDiD 1 -CLEAN-OUT -- PI~OPOSED WATER EASEMENT ,c¥' O' GEN. T~_ ESMT RELOCATE EX]STING RRE HYDRANT INSTALL: 1-6' 90' HORZ BEND 55 IF' 6' WATER PIPE SEE NOTE No. 1 :ATE EXISTING FiRE HYDRANT INSTALL: 1-6' 90' HORZ BEND 55 LF 6' WATER P~PE I,CV · ~ L5 6" SANI ----iNSTALL 6" SANI "'"" -- "--'-----1' 2.'"~ -- m--. PROPOSED 15 WATER EASEMENT ZO' U'RL & DRAIN. ESMT. R~W 515. 7~ STA 0+00 UNE 'SS-3' BEGIN 8' SANI SEWF__R SERVICE REMOVE CAP, INSTALL 1-SANITARY SEWER ACCESS DEVICE AS PER CiTY OF COPPELL STANDARDS FL 8'=503.80 SEE NOTE No. 1 BELT LINE DALLAS POWER & UGHT 06-18-56 D STA 3+1~,.5 UNE INSTALL: 1-6' 90' HORZ BEND FL 6'=512.2 RELOCATE EXISTING FIRE HYDRANT INSTALL: 1-6' 90' HORZ BEND, 55 LF 6' WATER PIPE SEE NOTE No. 1 CONNECT TO EX. 8" WATER UNE iINSTALL: 1-8'x8' TAPPING SLFFVE 1-8' VALVE 1-8' DETECTOR CHECK W/ VAULT EASEMENT INSTALD 1-8"x6' TEE 2-6' 4,5' HORZ BEND 1-6' VALVE 1-FIRE HYDRANT 140 LF 6' WATER LiNE NOTE: 1. TAP LOCATIONS AND TIMING OF CONSTRUCTION W~LL BE COORDINATED WlTH THE INSTALLATION OF THE FUTURE 16" WATER MAIN. PRELIMINARY NOT FOR CONSTRUCTION THIS DOCUMENT IS ISSUED FOR THE PURPOSE OF SCHEMATIC REVIEW ONLY AND IS NOT INTENDED FOR PERMITTING, BIDDING, OR CONSTRUCTION PURPOSES. PLANS PREPARED UNDER THE DIRECT SUPErviSiON OF STe,~ A. MA~USSEN, P.F. TEXAS REGISTRATION NO. 70090 DATF~ 04/12/2005 OF PROPOSED DRIVE, RELOCATE EX. SIGN BENCH MA LIST BM No, 1 BM No. 2 BM No. 3 BM No. 4 BM No. 5 · ri" CUT SET AT CORNER OF CURB, NORTHEAST CORNER OF MJ DESIGN TRACT, APPROX 40 FEET WEST OF SUBJECT TRACTS WEST UNE. ELEV. 516.46 · ri' C'UT. EAST END OF INLET ON NORTH SIDE OF AIRUNE DRIVE APPROX. go FEET WEST OF INTERSECTION OF AIRUNE DRIVE AND ENTERPRISE DRIVE. ELEV 519,82 "El' CUT ON CENTER OF INLET ON SOUTH SIDE OF AIRUNE DRIVE, APPROX. 110 FEET WEST OF INTERSECTION OF AIRUNE DRIVE AND EXECUTIVE DRIV~ ELEV. 520.77 'Fl" CUT OF CENTER OiF INLET ON SOUTH SiDE OF AIRLINE DRIVE APPROX 335 FEET WEST OF BELT LINE ROAD. ELEV. 516.87 'El' CUT CENTER OF INLET ON WEST SiDE OF BELT UNE ROAD AT THE NORTHEAST CORNER OF SIJBJECT TRACT. ELEV. 513.93 SEE SHEET Cl.O FOR GENERAL NOTES. ISSUED FOR PRELIMINARY PRICING PURPOSES ONLY (SUBJECT TO REVISION PRIOR TO CONSTRUCTION) THESE DOCUMENTS HAVE BEEN PREPARED BY THE ENGINEER WITH THE INTENT OF COMPLYING WITH ALL CITY STANDARD REQUIREMENTS. THESE DOCUMENTS HAVE NOT BEEN APPROVED AND RELEASED FOR CONSTRUCTION BY THE CITY AS OF THIS DATE AND, THEREFORE, REVISIONS MAY BE REQUIRED PRIOR TO CONSTRUCTION. BY ANY USE OF THESE DOCUMENTS, THE USER AFRRMS THEIR UNDERSTANDING OF THE PREUMINARY STATUS OF THE PLANS AND THE POTENTIAL FOR REVISION PRIOR TO ANY CONSTRUCTION. /& NO. 04./12/2005 DA TE REVISED WATER UNE /?EVI$10N 8350 N CENTRAL EXPWY SUITE 1000 DALLAS, TEXAS 75206 972.235.3031 WATER & SANITARY SEWER PLAN MAJESTIC LOT 2R-3, BLOCK 2 PARK WEST COMMERCE CENTER CITY OF C OPPEI Z, TEA'A $ DESIGN RCS BB PK FILE: 1628-05.034. DRAWN DATE $CAZE NOTES ! APRIL I 2005 1"=50' FIZ E OW(;, FILE.: NO. C4.1 1628-05-034.-CV. OWG