Water & Sanitary Sewer PlanS~
/
/
/
I
-4
J
6'
,",:
,3~ S
C~C
R--38.00'
T-37.75'
CH'-S 46'04'22' W
SS
:ESS ESMT.
)
C~AT~
,,' ', ~ 38' RCP~
GRATE
~LET
STA 0+00 UNE
BEGIN 8' SANI SEWER SERVICE
REMO~'E CAP, INSTALL
1-SANITARY SE~rr_R ACCESS
DEVICE AS PER CiTY OF
COPPELL STANDARDS
FL 8'=508.10
_ --..... ~TAII 6" ;ANI SEWER
N 00"~3'14,' E
STA 2+30.0 LINE
INSTALL:
1-6' 90' HGRZ BEND
1 -CLEAN-OUT
FL 6'=512.50
LOT 2.R, BLOCK 2
PARK WEST OMMERCE CENTER
N 0~'~'14'~ E 728.56'
STA 1+78.0 UNE
INSTALL:
1-6' 90' HO~Z BEND
1-CLEAN-OUT
FL 6'=512.90
LS '~a ICY
INISTALL SANI SEWER
89'06'4-6' E
15.50'
STA O+OC UNE
BEGIN 8" SANI SEWER SERVICE
REMOVE: CAP, INSTALL
-SANITARY SEWER ACCESS
DEVICE AS PER CITY OF
COPPED_ STANDARDS
q_ 8"=510.90
INSTALL
1-3' WATER SERVICE
i'x2' REDUCER
1-2' WATER METER
W~)OUBL~' C~ECK (DIOMESTIC)
-3'x2' REDUCER
,INSTALL 3" WATER SERVICE
TO A POINT 3' OFF BLDG
END & CAP
INSTALL:
1-8'x6' TEE
1-6' VALVE
1-RRE HYDRANT
STA 0+38.0 UNE
END 8' SANITARY SEWER
BEGIN 6' SANIRATY SEWER
INSTAl l:
1-STD 4; DtA NANHOII:'
W/CHIMNEY SEAL
BEGIN 6' SANI SERVICE (SE)
INSTALL DOUBLE CLEAN-OUT
3' OFF BLDG, END & CAP
FL 0 BLDG=514.00
FL 8' OUT=508.50
6' IN =508.70
INSTALD
1-8'x6' TEE
1-6' VALVE
1-FiRE HYDRANT
STA 2+59.5 UNE "SS-l'
END & CAP 6" SANI
SEWER SERV1CE AT
A POINT 3' OFF BUILDING
INSTALl:
1-DOUBLE =CLEAN-OUT
Fl. 0 BLDG 514.00
PROPOSED FIRE
DEPARTMENT
CONNECTION SHOWN
FOR REFERENCE
ONLY, REFER TO
RRE PROTECTION
PLANS FOR DETAIl_
F1NISH FLOOR
F1 FVATION=519.5.0
INSTALL 8' WATER,
STA 2+07.5 UNE 'SS-2'
END & CAP 6' SANI
SEWER SERVICE AT
A POINT 3' OFF BUlL.DING
INSTALL:
1-DOUBLE CLEAN-OUT
FL 0 BLDG=514.00
1-8%6' TEE
1-6' VALVE
1-FIRE HYDRANT
STA 0+42,0 UNE
END 8' SANITARY SEWER
BEGIN 6' SANIRATY SEWER
INSTALL:
1-STD ,~' DIA MANHOLE
W/CHIMNEY SEAL
BEGIN 6' SANI SERVICE (SE)
INSTALL DOUBLE CLEAN-OUT
3' OFF BLDG, END & CAP
FL {3 BLDG=51~.O0
FL 8" 0'UT=511.30
FL 6" IN =5tl,50
INSTALL:
1-8'x6' TEE
1-6' VALVE
1-FIRE HYDRANT
0 25 50 lOO 150
GRAPHIC SCALE IN FEET
F~'<> FIRE HYDRANT
PP, POWER POLE
I L$
~-I %t- UGHT STANDARD
'~1 ~o WATER METER
w'vo WATER VALVE
coo CLEANOUT
UH O~_] MANHOLE
GU <S OAS METER
.... PROPERTY UNE
20'x35'
WATER EASEMENT
CONNECT TO EX. 8'
WATID~ UNE
INSTAll-'
1-8'x8' TAPPING
1-8" VALVE
1-8' DETECTOR CHECK
W/ VAULT
iTALL 8'
INSTAll_'
4--6' DIA. STEEL GUARD
POSTS SPACED A MIN.
APART. REFERENCE OTY
OF COPPELL STANDARD
DETAIL
INSTALL 8" WATER
iNSTALl.; '~
1-8' CROSS
2-8' VALVES
INSTALL 2-8' FIRE PROTECTION
SERVICES TO A POINT 3' OFF
BUILDINGS, END & CAP
TALL:
1-3' WATER SERV1CE
REDUCER
1-2' WA~
W/D~B~ CHE~ (D~ES~C)~
1-3'x2' REDUC~
tNSTA~ 3' WA~
~ TO A PONT 3' O~
STA 4+42.5 UNE 'SS-3"
END &~ CAP 6' SANI
SEWER SERVICE AT
A POINT 3' OFF BUILDING
INSTAll-'
1-DOUBLE CLEAN-OUT
FL 0 BLDG=513.50
STA 2+50.0 UNE
INSTALL~
1-6'x6' WYE CONNECTION
1-6' SANI SEWER SERVICE
INSTALL DOUBLE CLEAN-OUT
3' OFF BLDO, END ~ CAP
FL 0 BLDG=,513.50
FL 6' 0 WYE=509.00
RNISH FLOOR
ELEVATION= 519.00
STA 0+67.0 UNE
=STA 0+00 UNE 'SS-4"
END 8' SANITARY SEWER
BEGIN 2-6' SANIRATY SEWF_R
INSTALL:
1-sm ~' D~^ MANHOLE
W/C.H, IM NEY SEAL
FL 8 OUT=505.10
FL 6" IN =505.30
STA 1+52.0 UNE 'SS-4'
INSTALL:
1-6'x6' WYE CONNECTION
1-6" SANI SEW~ SERVICE
INSTALL DOUBLE CLEAN-OUT
3' OFF BLDO, END ,~ CAP
FL 0 BLDG=513.50
FL 6' 0 WYE=508.30
STA 3+4-4.5 UNE 'SS-4'
END & CAP 6' SANI
SEWER SERVICE AT
A POINT 3' OFF BUILDING
INSTALL:
1-DOUBLE CLEAN-OUT
FL 0 BLDG=,513.50
INSTALL:
1-8'x6' TEE
1-6' '/ALVE
1-RRE '.';YDRANT
I
15'x50'
tNSTAL~
1-2' WATER SERVICE
1-2' WATE. R METER
(IRRIGATION)
L$
'r~ · [] TS~ jU'N,CllC~
nBOX
PP
50' LS. GAS
(VOL 157'7, PG. 8)
,(VOL 2017, PG. 69)
VOL. 71167, PO. 1303)
VOL g0097, PG. 114-4)
6" SANI SEWER'
--- '-"e~~ i_ _.. ---
STALL 6" SANI
STA 44-12.5 UNE
INSTAll-'
1-6' 90' HORZ BIDiD
1 -CLEAN-OUT
--
PI~OPOSED
WATER EASEMENT
,c¥' O' GEN. T~_ ESMT
RELOCATE EX]STING
RRE HYDRANT
INSTALL:
1-6' 90' HORZ BEND
55 IF' 6' WATER PIPE
SEE NOTE No. 1
:ATE EXISTING
FiRE HYDRANT
INSTALL:
1-6' 90' HORZ BEND
55 LF 6' WATER P~PE
I,CV · ~ L5
6" SANI
----iNSTALL 6" SANI
"'"" -- "--'-----1' 2.'"~ -- m--.
PROPOSED 15
WATER EASEMENT
ZO' U'RL & DRAIN. ESMT.
R~W 515. 7~
STA 0+00 UNE 'SS-3'
BEGIN 8' SANI SEWF__R SERVICE
REMOVE CAP, INSTALL
1-SANITARY SEWER ACCESS
DEVICE AS PER CiTY OF
COPPELL STANDARDS
FL 8'=503.80
SEE NOTE No. 1
BELT LINE
DALLAS POWER & UGHT
06-18-56
D
STA 3+1~,.5 UNE
INSTALL:
1-6' 90' HORZ BEND
FL 6'=512.2
RELOCATE EXISTING
FIRE HYDRANT
INSTALL:
1-6' 90' HORZ BEND,
55 LF 6' WATER PIPE
SEE NOTE No. 1
CONNECT TO EX. 8"
WATER UNE
iINSTALL:
1-8'x8' TAPPING
SLFFVE
1-8' VALVE
1-8' DETECTOR CHECK
W/ VAULT
EASEMENT
INSTALD
1-8"x6' TEE
2-6' 4,5' HORZ BEND
1-6' VALVE
1-FIRE HYDRANT
140 LF 6' WATER LiNE
NOTE:
1. TAP LOCATIONS AND TIMING OF
CONSTRUCTION W~LL BE
COORDINATED WlTH THE
INSTALLATION OF THE FUTURE 16"
WATER MAIN.
PRELIMINARY
NOT FOR CONSTRUCTION
THIS DOCUMENT IS ISSUED FOR THE
PURPOSE OF SCHEMATIC REVIEW ONLY
AND IS NOT INTENDED FOR PERMITTING,
BIDDING, OR CONSTRUCTION PURPOSES.
PLANS PREPARED UNDER THE DIRECT
SUPErviSiON OF STe,~ A. MA~USSEN, P.F.
TEXAS REGISTRATION NO. 70090
DATF~ 04/12/2005
OF PROPOSED DRIVE,
RELOCATE EX. SIGN
BENCH MA LIST
BM No, 1
BM No. 2
BM No. 3
BM No. 4
BM No. 5
· ri" CUT SET AT CORNER OF CURB, NORTHEAST CORNER OF MJ DESIGN
TRACT, APPROX 40 FEET WEST OF SUBJECT TRACTS WEST UNE.
ELEV. 516.46
· ri' C'UT. EAST END OF INLET ON NORTH SIDE OF AIRUNE DRIVE
APPROX. go FEET WEST OF INTERSECTION OF AIRUNE DRIVE AND
ENTERPRISE DRIVE.
ELEV 519,82
"El' CUT ON CENTER OF INLET ON SOUTH SIDE OF AIRUNE DRIVE,
APPROX. 110 FEET WEST OF INTERSECTION OF AIRUNE DRIVE AND
EXECUTIVE DRIV~
ELEV. 520.77
'Fl" CUT OF CENTER OiF INLET ON SOUTH SiDE OF AIRLINE DRIVE
APPROX 335 FEET WEST OF BELT LINE ROAD.
ELEV. 516.87
'El' CUT CENTER OF INLET ON WEST SiDE OF BELT UNE ROAD AT
THE NORTHEAST CORNER OF SIJBJECT TRACT.
ELEV. 513.93
SEE SHEET Cl.O FOR
GENERAL NOTES.
ISSUED FOR PRELIMINARY PRICING PURPOSES ONLY
(SUBJECT TO REVISION PRIOR TO CONSTRUCTION)
THESE DOCUMENTS HAVE BEEN PREPARED BY THE ENGINEER WITH THE INTENT OF
COMPLYING WITH ALL CITY STANDARD REQUIREMENTS. THESE DOCUMENTS HAVE NOT
BEEN APPROVED AND RELEASED FOR CONSTRUCTION BY THE CITY AS OF THIS DATE
AND, THEREFORE, REVISIONS MAY BE REQUIRED PRIOR TO CONSTRUCTION. BY ANY
USE OF THESE DOCUMENTS, THE USER AFRRMS THEIR UNDERSTANDING OF THE
PREUMINARY STATUS OF THE PLANS AND THE POTENTIAL FOR REVISION PRIOR TO
ANY CONSTRUCTION.
/&
NO.
04./12/2005
DA TE
REVISED WATER UNE
/?EVI$10N
8350 N CENTRAL EXPWY SUITE 1000 DALLAS, TEXAS 75206 972.235.3031
WATER & SANITARY SEWER PLAN
MAJESTIC
LOT 2R-3, BLOCK 2
PARK WEST COMMERCE CENTER
CITY OF C OPPEI Z, TEA'A $
DESIGN
RCS BB
PK FILE: 1628-05.034.
DRAWN DATE $CAZE NOTES !
APRIL I
2005 1"=50'
FIZ E
OW(;, FILE.:
NO.
C4.1