Loading...
DRC commentsCOPPELL Prelect ID PD-05-0017 Address Bethel Rd Proiect Type Re-Zoning PD Aeelication Date 4/22/2005 Case Manaqer Matt Steer Prelect Descrtotion Agency Building Inspection CITY OF COPPELL DRC REPORT Proiect N COPPELL PD-108-Re-H Bethel Historic Properties Zoning change request from PD-108-H (Planned Development-108-Historic) to I~D-108oRe-H (Planned Development 106 Revision 6-Historic), to attach a Detail Site Plan to allow the development of twc 32,995-square-feet on approximately 33 acres of property 1 of 2 Reviewed By Review Date Greg Jones 4/27/2005 medical offices totaling 1. Buildir~gs will need automatic fire sprinkler system installed. Electric and Gas Engineering Fire Administration Parks and Recreation Planning Department Jeff Curry 4/29/2005 Zoning ct Charlene La Mattina 4/29/2005 No comn" Tim Oates 4~29~2005 1. Future prior to c( 2. Show ~ proposed two on sit size and ~ fire depar 3. Fire hy looped sy of 150' a, 4. Indicat~ 5. Autom~ directly fr, John Elias 4/29/2005 Tree rem, Matt Steer 4/27/2005 Elevation 1. Consid lintels (ca 2. Show Clear win, ange acceptable. 9nfs. ;onnection to S. Coppell shall be completed nstruction of Phase I building. xisting fire hydrants on E. Bethel and fire hydrants on Site Plan. A minimum of .~ hydrants are required based on building onstruction type. Coordinate location with merit. Jrant water line will be required to be a ~tem, no dead-end fire hydrant lead in excess e permitted. ~ Fire Dept. Connection (FDC) location. tic fire sprinkler room shall be accessible ,m the exterior of the building. ,val permit is required at time of construction. ;r a different material than steel for the ~t stone). ~or, window, light fixture and gutter details. lows are required. 3. How ar~ porch entries lit? 4. Show ploposed sign areas (sq. ft.), indicate with a dashed b~x on the elevations, and label "proposed sign area'I. Show sign materials and colors. If lit, sign shall be t~p lit down with little or no spill over. 5. Please ~submit a color board with materials and accurate (}olor rendering at the DRC Meeting. 6. Show p~rking lot lighting detail. This should be the same acoln style streetlight as approved within the Old Coppell 'l]ownhomes. 7. Brick fo~undation required. 8. Consid, ~r adding entrance on west corner elevation. Site Plan: 1. Note or plans all PD Conditions. (1. Phase II parking area Ioca ed in front yard. 2, Perimeter and nonvehict lar landscaping not met.) 2. Show h')w building will function with and without proposed improvements to Bethel Road. COPPELL Agency Reviewed By CITY OF OOPPELL DRC REPORT Review Date CommentS COPPELL 3. Indud~setbacks from the existing and proposed back of c~rb. 4. Move I~hase two building at least 10' from the property I!ne, as this is a perimeter landscaping requirement. 5. Indicat~ existing (PD-108-H) and proposed (PD-1081~6-H) zoning within Site Data Table. 6. Show ~reposed FDC, firelanes and fire hydrants. Replace '~fireline" with "firelane". Show turning radii for firelan~ (minimum 30' inside, 54' outside). 7. The southern boundary is adjacent to a planned pedestria~ trail system. Coordinate with Parks and RecreatidFn for a tie in. 8. We question the proposed on-site sidewalk as it is located 1(p-15' away from the proposed sidewalk within the Bethe~ Road improvement plans. Consider landscap 3g in its place. 9. Parent 9nt width of drive aisle needs to be reduced to 24'. TI e extra 4' is better suited for landscaping than pay(merit. 10 Chan provide 2 11. Exten property I and Utilil 12. Rem¢ the mutu~ 13. Show 14. Show paver typ Design G Landscal: 1. A Land plans. 2. Is side~ calculatio 3. A land.~ a tree is r end of ea 300 sq. ft island sp~ 4. 10' peri streets cl~ 5. We rec Elms alon what's sh, 6. Submit te parking abutting sidewalks to 17' and landscaping. ~ common access easement to southern ne. Rename to "Firelane, Mutual Access Easement". ye the firelane dashed line extending into I drive. stamped concrete or brick pavers at entry. details of proposed on-site sidewalk (color, ~) as encouraged within the Old Coppell ]idelines. Plan: ~cape Architect is required to seal landscape ~alk included within the interior landscaping is (29,059 sq. ft.)? cape island, minimum 150 square feet, with 9eded every 15 parking spaces and at the :h parking row. Two trees are needed on a island serving two rows of parking. Revise cing on south end. ~eter landscaping is required adjacent to ssified as secondary image zones not 15'. )mmend changing Live Oaks to Lacebark ] Bethel frontage as this is consistent with ,wn in the Bethel Road Improvement Plans. tree survey. Project ID MP-05-0018 Address Bethel Rd DRC REPORT Proiect N~tme COPPELL Bethel Historical Properties Addition, Lots 1, 2 Project Type Application Date Case ManaRer Project Description Minor Plat 4/22/2005 Matt Steer to allow the development of a 16,677 square foot medical office on Lot 1 contair~ing 1,615 acres of property and p~atting Lot 2, containing 1.641 acres for Phase Two Agency Building Inspection Electric and Gas 1 of 3 Reviewed By Review Date Greg Jones 4127/2005 Jeff Curry 4/29/2005 Plat unacceptable. Please co~ntact Larry Redick at 972-323-8917 to electric easement requirements. discuss CC PPELL Project ID MP-05-0018 Address Bethel Rd 2nd DRC REPORT Project N~me COP?ELL Bethel Historical Properties AdditiOnr Lots 1, 2 Project Type Application Date Case Manager Project Description Minor Plat 4/22/2005 Matt Steer to allow the development of a 16.677 square foot medical office on Lot 1 contaii~ing 1.615 acres of property and platting Lot 2, containing 1.641 acres for Phase Two Agency Engineering 1 of 1 Comments Plat 1. Include easements for fire lanes, sidewa ks, mutual access and utilities as necessary. Ensure that adequate ROW is dedicated for futurelBethel Road improvements. Preliminary Drainage Area Map 2. Please refer to the plans for the future improverdents of Bethel Road, which are available at the Engineering Department. There should be correlation between the drainage areas proposed for Bethel Road and this site. Additionally, an inletlis planned along Bethel Road in the location of the second walk from the west. Modify the walk tic avoid conflict. Preliminary Grading Plan 3. Construct an inlet system with piping instead of al concrete flume for drainage to the ditch at the north east corner of the parking lot. Refer to future improvements of Bethel Road; the swale/ditch will be replaced with subsurface drainage. Constructed inlet(s) for this site may be temporarily modified to allow flow to the swale/ditch until such time as Bethel Road improvements are in place. Preliminary Utility Plan 4. The fire lines for these sites must be looped. On~ fire hydrant will not be adequate for these two lots. Construct a public water line in a 20' easement from Bethel Road to Coppell Road and provide a stub-out to the park property to the southi Public hydrants serving Lot 1 and Lot 2 may be constructed, however easements must be I~rovided. Private fire lines serving the building sprinkler systems and any private hydrants~that are constructed should be served after the DDC's. Minimum 25' x 25' easements should be provided for DDC's and water meters. Will all of the lease spaces share one water meter, lot will the units be metered individually? Show the locations of the FDC's. (Be sure water is ~shown to be tied into the 16" W and not the 12" SS.) 5. Will a 4" sanitary sewer line be adequate to serv!ce the proposed building and the uses at each unit? Should each unit have its own sewer connection? Sanitary sewer may need to be re-designed to serve each unit. Provide an easeme~nt for any utility that is required to be public and a MH or CO, as appropriate, where the privateisystem meets the public system. 6. Show curve radii for the fire lanes. Agency Fire Administration Parks and Recreation Planning Dep~rtment Reviewed By Tim Oates John Elias Matt Steer DRC REPORT Review Date 4/29/2005 4/29/2005 4/27/2005 COPPELL Commentq 1. Show Re lane on plat. 2. Insure l~re lane radii - 30' inside, 54' outside. 3. Fire hydrant(s)? A minimum of 3 hydrants for the properly ~ill be required; two for Phase I and an additionallhydrant for Phase I1. 4. Propos 9d fire hydrant exceeds the 150' dead-end, must be I, ~oped. Coordinate water line placement with Engineer ng Dept. and fire hydrant placement with Fire Dept 5. Indicat, ~ the Fire Dept. Connection (FDC) location. Must be '~ ,ithin 50' of a fire hydrant and on the same side of th. ~ fire lane/road Tree rem, ~val permit is required at time of construction. 1. Revise owner's certificate to read "Bethel Historical Propertie; Addition" in place of "Coppell Old Town Addition". 2. Revise the Volume # of the Owner's Certificate to match th~ t which is shown on the property, or revise that of th(' property to show what is shown in the Owner's ( ;ertificate. 3. Replac Utility Certificate with: Atmos Date TXU EleCtric Delivery Date Co~mcast Date V~rizon Date 4. Revise~distance on west property line to reflect 80.42 fee! and 195.3 feet segments as noted in field notes. ~ 5. ExtendlAccess Easement to southern property line and renan~e to "Fire Lane, Mutual Access and Utility Easement". 6. Replac~ Planning and Zoning Commission verbage with "RecOmmend for Approval" within signature block. 7. Remove: Attest: ~ Secretaryl Planning and Zoning Commission City of Co~pell, TX 8. Add: A~proved and Accepted: Mayor Date City of CoppelL TX 9. Fill in Bank within the City Secretar7 signature block to read "l~ethel Historical Properties Addition". 10. Make Image and scale larger. 11. Show ~roposed fire lanes with bearings and distances. MEMQRANDUM To: Matt Steer From: Jeff Curry Date: April 29, 21XI5 Subject: May DRC PD-108R6-H, Bethel Historical Properties - Zoning Changq Acceptable Bethel Historical Properties Addition, Lots 1 and 2, Block ~ Minor Plat - Plat Unacceptable, please contact Lan'y Redick at 972-323-8917 tO discuss electric easement requirements. PD-210-SF-9(CH), Kaye Street - Zoning Change Acceptabl~ ~l-~ 200/ZO0~ £~9-2 + 13Q ~lHL33q3 flX2-UoJJ mego:eo 600Z-GZ-PO