Loading...
DRC commentsCOI:'I ELL CITY OF COPPELL CO?I ELL DRC REPORT Project iD SPA-05-0054 Project N~tme Beltline Trade Center, Lot 1, Block 2, Site Plan Address Project Type AoDlication Date Case Manacler Proiect Descrlotion Site Plan Approval 10/20/2005 Gary Sieb To allow the development of an approximate 23,336-square-foot office/warehouSe building. Agency Building Inspection Electric and Gas Engineering 1 of 2 Reviewed By Review Date Greg Jones 10/27/2005 Jeff Curry 10/28/2005 Charlene La Mattina 10/27/2005 Fire Administration Tim Oates 10/27/2005 Parks and Recreation John Elias 10/25/2005 1. No flo~ plans submitted, No building construction informatio~ furnished. No comments were able to be made. Site Plan, ~cceptable. Site Plan:', 1. The ori~ ,ntation of the drawings should be consistent througho~ 't the entire drawing set. 2. Show tte location of the FDC on this sheet. 3. Be advi ;ed that the portion of Belt Line Road adjacent t, ) the site lies within the Dallas City limits. The propcsed modifications to the medians should be approved 3nd permitted by the City of Dallas. Light standards in the medians may need to be relocated. 1. Fire hy('rants shall be within 3 to 6-feet from fire lane. 2. Fire hyc~rants and fire department connection (FDC) shall be sllown on Site Plan and Utility Plan, 3. FDC mc~st be detached from the building a minimum c~istance of 1 1/2 times the height of the building. R',DC must be within 50 feet of a fire hydrant and on the~ same side of the fire lane. 4.6" Fire I~ine is a minimum size, must be verified by submitting!hydraulic calculations to the Fire Dept. for review pr, ic[r to installation. 5. The 6' I~DC on the Fire Line is a minimum size. This DDC ~nay be removed when the rest of the water line projec~ is brought up to City standards. 1. Tree re~noval permit will be required prior to start of constructi~)n. COPPELL ~lanning Department Reviewed By Gary Sieb CITY OF COPPELL DRC REPORT Review Date Comments 10/26/2005 COPPELL NOTE: O~ient all drawings in the same direction. As a general rule, North should be to the top of all exhibits. SITE PLA~I 1. Includelfront, side, rear yard required yards on Site Plan. 2. Show o!verall building setbacks from all property lines. 3. Includeitypical length of parking space (19' long). 4. DimenSion entry drive widths. 5. Indicat~ row of Beltine Road as well as median widths. 6. Monum~e, nt sign must be at least 15 feet behind property lithe and 75 feet from side lot line. NOTE: A ~umber of these comments can be addressed! by combining Site Plan data with Sheet A1.00 data on one drawing. LANDSC,~PE PLAN 1. Plant li~t shows trees at 4" caliper--Landscape Table sho~vs 3" caliper. 4" caliper needed to address mitigation]ssue. 2. Parkin~lots need to be screened from Beltline by berms, he(~ges, landscaping, etc. 3. Indicat(~ fire lane on plan. 4. Show bbilding setbacks from all property lines. ELEVATIC~NS 1. Show h~ight, width, length on all elevations. 2. Color Bbard will be required prior to final submissior~. GENERAl.{ 1. Sheet ~1.00 not needed for this review if upper left corner info~'mation is transposed to Site Plan.