Loading...
DRC comments-10/4/01Development Review Committee Comments Planning Department S-1195 SPRINT PCS Andrew Brown Community Parl Centeral 364 N. Denton Tap Roa l DRC Date: September 27, 2001 and October 4, 2001 Planning & Zoning Commission Meeting: October 18, 2001 City Council Meeting: November 13, 2001 Revise Vicinity Map to more clearly show the site Iocgtion. As curremly indicated, the park is located north of Vista Ridge (S.H. 121), while it is actually located south of Vista Ridge (S.H. 121 ). Revise street name to indicate the current name of S.H. 121 and cemer in on the subject site within Coppell; the ama shown is extensive. Revise Zoning Map to eliminate 200' notification radius. This does not follow the specific zone notification boundaries. Remove notation on site data table that indicates the tq~wer will be placed on Lot 1, Block A; the Andrew Brown Community Park Cenlral is not platted property and therefore does not contain a legal description in st~ch a manner. Approximate indication of the location is acceptable. Such as, the specific distance east of Denton Tap Road. As shown, the enclosure is placed at grade, which ma3t not be permitted in the 100-year floodplain (See Engineering comments); however, the equipment is elevated. Please indicate the dimension from ground llevel to the equipment. Relocate the proposed access doors serving the ground level equipmem area to a less visible location. If necessary, extend the sidewal!~ to the rear/side of the enclosure to shift the doors to the mar/side of the encl,sure. Provide some level of landscaping around the enclose/t area. Staffwould recommend the placement of Nellie R. Stevens, or similar shrub, around the base of the enclosure. lndicatethejustification for the size ofthe 625 square foot enclosure. It appears that approximately 242 square feet within the enclosUre does not house equipment and is simply an open gravel area. Clarify that the existing park lights measure 77' in height (as seen on a note on the plan). The AT&T tower measures 80' in height (70' tO the lights). The proposed Sprint tower measures 85' in height (72 & 75' to the lights). The existing and proposed heights appear to be very inconsistent. Staff would recommend that the applicant reduce the height of the tower to not exceed lg0' in height and attempt to design the overall pole height and the light sources in alignment with existing conditions on the site. Revise Sprint PCS Site Detail on sheet 2 of the submission to indicate the height to the light sources. Note: A Please revise plats, site plans, landscape plans, and b~ilding elevations based on staff recommendations. Should applicant disagree With staff comments please provide reasons why staff recommendations should aot be followed when you attend the October 4th Development Review Commiltee (DRC) meeting. Each applicant will bring two new sets of revised pl~ts and plans to the October 4th DRC meeting. Applicants will be asked to show, explain and defend any revision. An Engineer for the project or other representative is urged to attend the meeting. Applicant will have till noon Tuesday, October 9th! to resubmit fourteen (14) folded copies of revised plans, three (3) reduced paPer copies (8 1/2 X 11) and JPEG files or POWERPOINT SLIDES of each exhibit to the Planning Department. DEVELOPMENT REVIEW COMMITTEE PARKS AND LEISURE SER VICES CqOMMENTS ITEM: Sprint PCS DRC DA TE: September 27, 2001 and October 4, 2001 CONTA CT: John Elias. Landscape Manager COMMENT STATUS: PR EL IMINA R Y~ 1) Need to know if the parking spaces will be lost. 2) Timing o£ this project will need to be scheduled with to not al£ect any games. 092701sprintpcs the Parks department, so as DEVELOPMENT REVIEW COMMITTEE BUILDING INSPECTION COMMENTS ITEM: Sprint PCS DRC DATE: September 27, 2001 CONTACT: Greg Jones, Chief Buildlng Offwlal ($04-3500) , 1. Structural design information will be required upon permit application submission. 2. drc12~45 DEVELOPMENT REVIEW C MMITTEE ENGINEERING COMMENTS ITEM: S-1195. Svrint PCS, zoning change request fi'pm TC (Town Center) to TC- S.U.P-1195 (Town Center, Special Use Permit4 195), to allow the construction of a telecommunications tower at Andrew Bf0wn Community Park Central located at 364 N. Denton Tap Road, along the e~st side of S. Denton Tap Road; north of Parkway Boulevard, at the request of Hart Mason. DRC DATE: September 27, 2001 and October 4, 2001 CONTACT: Kenneth M. Griffin, P.E., Director of Enginee~ng (972-304-3679) COMMENTSTATUS: 1. The proposed location is within a floodplain/floodway, therefore, a Floodplain Development Permit will be required. The Floodplain Development Per, nit should include all necessary information as required by Article 4, Section C of ~e City of Coppell Floodplain Management Ordinance. The City hired Halff Associates to perform a flood study in January 2000 that showed the proposed location would remain in a floodplain even after a reclamation. However, there may be other locations slighil~ north and west of the proposed site which could be supported from a floodplain perspective. 2. Provide elevation of platform that the equipment is on. DEVELOPMENT REVIEW C( ENGINEERING COMM] M. MI-TFE NTS ITEM: S-1195, Sprint PCS, zoning change request frown TC (Town Center) to TC- S.U.P-1195 (Town Center, Special Use Permit-1195), to allow the construction of a telecommunications tower at Andrew Br~wn Community Park Central located at 364 N. Denton Tap Road, along the east side of S. Denton Tap Road; north of Parkway Boulevard, at the request of Haft Mason. DRC DATE: September27, 2001 and October 4, 2001 CONTACT: Kenneth M. Griffin, P.E., Director of Engineering (972-304-3679) COMMENT STATUS: 1. The proposed location is within a floodplain/floodway, there Permit will be required. The Floodplain Development Peru information as required by Article 4, Section C of the City of~ Ordinance. The City hired Halff Associates to perform a fl, showed the proposed location would remain in a floodplain ew there may be other locations slightly north and west of the supported from a floodplain perspective. 2. Provide elevation of platform that the equipment is on. 'ore, a Floodplain Development it should include all necessary ;oppell Floodplain Management ~od study in January 2000 that n after a reclamation. However, proposed site which could be TXU TXU Electric & Gas 4200 N. Belt Line Irving, TX 75038 September 24, 2001 Comments for City of Coppell Development Review Committee S-1195, Sprint PCS Zoning Change Acceptable Bobby Oney