Loading...
CC approval on 9/12/2006 THE.CITY.OF DEPT: Planning ~.eJ:",.r L," z."( IJ '/' . DATE: :\URHot "',-2006 AGENDA REQUEST FORM COPPELL ITEM #: 15 ITEM CAPTION: PUBLIC HEARING: Consider approval of the Case No. S-1236-A. MetroPCS, zoning change request from A (Agriculture) to S-1236-A (Special Use Permit-l 236-Agriculture), to allow for a wireless communication antenna to be mounted to an existing electric transmission tower, with an accessory cabinet with enclosure at the base of the tower, located approximately 1,700-feet southwest of the intersection of MacArthur Boulevard and the transmission line easement; north of Belt Line Road Motion to close Public Hearing and approve, subject to condition 1 below GOAL(S): APPROVED BY CITY COUNCIL ON ABOVE DATE M - Peters S - Faught Vote-l-O EXECUTIVE SUMMARY: . Libby Ball ~2006.09.2 . .' 217:34:31 -05'00' Date ofP&Z Meetine: August 17,2006 Decision ofP&Z Commission: Approval (6-0) with Commissioners Borchgardt, Hall, McCaffrey, Foreman, Kittrell and Reese voting in favor. None opposed. Approval is recommended, subject to the following conditions: 1) Departmental comments (Engineering) attached. Agenda Request Form - Revised 09/04 Document Name: @6S-1236-A, MetroPCS l-AR P&Z HEARING DATE: C.C. HEARING DATE: STAFF REP.: LOCATION: SIZE OF AREA: CURRENT ZONING: REQUEST: APPLICANT: HISTORY: CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT CASE: S-1236-A'I MetroPCS August 17, 2006 September 12, 2006 Gary L. Sieb, Director of Planning Approximately 800 feet northwest of the intersection of MacArthur Boulevard and Beltline Road. Approximately 15 feet by 20 feet at base oftower. A (Agriculture) A-SUP (Agriculture, Special Use Permit) to allow six wireless communication antenna to be mounted on an existing electric transmission tower, with an accessory cabinet and structure at the base ofthe tower. Metro PCS c/o Dave Green 416 Fountain Park Drive Euless, TX. 76039 (817) 692-1989 Fax: (817) 860-0077 There has been no recent zoning history on the subj ect tract although there was a zoning case requesting a similar use on the electric tower immediately to the east of this request in 1999. ITEM # 9 Page 1 of3 TRANSPORTATION: Beltline Road is an improved, P6D, six-lane divided concrete thoroughfare contained within a lID-foot r.o.w. MacArthur Boulevard is another improved P6D located just east of the subj ect property. SURROUNDING LAND USE & ZONING: North - TU electric power line; SF-9 and "A", Agriculture South - TU electric power line; SF-9 and "A", Agriculture East - commercial buildings; "C", Commercial West - Single family subdivision; SF-9 COMPREHENSIVE PLAN: The Coppell Comprehensive Plan, as amended, shows this property as suitable for open space and flood plain uses. DISCUSSION: This request would allow a group of six communication antenna (4.5 feet long by 8 inches wide by 2.75 inches thick) to be mounted at the top of an existing, 114 foot tall TXU electric transmission tower in the Riverchase area. It would be very similar to an adjacent SUP for a communication antenna granted in 1999. At the base of the tower an approximate 15 feet by 20 feet maintenance building is proposed. This structure would be six feet high and of masonry construction. It would be similar in appearance to the existing cell tower building just east of this proposal. As a general rule, these requests are pretty straightforward and generate no public input. That is not the case with this proposal, however, as there has been some limited (5) opposition responses to this request. There are two other sites nearby that garnered no comments when zoned. Concern generated by this application relates to the number of similar facilities in the TXU easement, maintenance, and access to the equipment structure, among others. A condition of staff review relates to access being provided east of the tower, not along the alley on the west side of the power line structure as submitted. This revised access would eliminate some citizen concern. If staff proposed access is recommended, the base structure would need to provide entry gates on the east side of the building, not the west side as now shown. Although there is some opposition, staff can support this request for a variety of reasons. Several TXU structures have been here for over twenty years and are, by far, the most dominant structures in the area; the six antennas will be placed 114 feet above the ground; the antenna themselves are only 4.5 feet long by 8 inches wide thus creating no visual obstruction to any surrounding neighborhood. The maintenance structure at the base of this tower will be similar to the other ones in the vicinity and complies with all our development guidelines (color, building materials, gate design, etc.). In addition, it is at least 100 feet from any residential structure and all homes have 6 foot rear fences, screening the maintenance building from their view. With conditions regarding modified access and utility locations (where access connects, surface, etc. and utility concerns--see Engineering comments), staff can support the request. Provided staff concerns are addressed, we feel it will have minimal land use impact on the adjacent properties. ITEM # 9 Page 2 of3 RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staff is recommending APPROVAL of this request, subject to the following conditions: 1) Provide access to site from east of tower, not along alley west of tower. 2) Submission of additional information regarding access concerns 3) Explanation of utility provision and location 4) Departmental comments (Engineering) ALTERNATIVES: 1) Recommend approval of the request 2) Recommend disapproval of the request 3) Recommend modification of the request 4) Take under advisement for reconsideration at a later date. ATTACHMENTS: 1) Submittal package (cover sheet, detailed site plan, elevation, fence detail, antenna orientation) 2) TXU permission letter 3) Antenna cut sheet 4) Inventory of existing towers 5) Departmental comments (Engineering) ITEM # 9 Page 3 of3 ATXU ~.~ TXU Electric Delivery 115 W, 7'h Street Ft. Worth, Texas 76102 Tel: 817-215-6658 Fax: 817-215-6600 DReese1@txued.com David Reese Right of Way July 6, 2006 City of Coppell Dear Sirs: This is to inform you that MetroPCS has requested permission from TXU Electric Delivery to attach a wireless telephone antenna to tower T -311 located in the City of Coppell in the area of MacArthur Blvd. and Beltline Road. TXU Electric Delivery grants MetroPCS permission to apply to the City of Coppell for all permits necessary for this possible attachment. Sincerely, /l David Reese TXU Electric Delivery Right of Way .-.---:-:.:'"" ...-...".-,....... ...,.., ~\ ~ ~ 1 -:- ;:;;;. ': ," .r! ; '.- '~r-~l \ _. ~-"-'~') ',:~', \\;'. /"'" ,I; \ . r t._ -.... 'l, r.'" __ ", ....../ \. "1 t, I. \ '; It' \ t,..~_ '~_',' ..,._1.... , .~'" ..,. ;. ~~; ~: ....*7:.- .. -..... '~ ~'\ ~ :~~.. \. l\ \. 1\'; ,,;( It// 2006 \ 'I' l;--:"~ Jut 1 9 ~,LI:\ \, \\~jj U \.~ .. ...--"..... "." ......,;~t!'I~ ~,. --.'-'" .". .......... A , COBRA MET fRET DUALPOL@ MET Mechanical Knob Assembly ~ "..,.'t.,t 2.75"~' J ".1 I ~-, Hln'[('o'l'<; Electrical Specifications Azimuth Beamwidth (-3 dB) Elevation Beamwidth (-3 dB) Elevation Sidelobes (Upper) Gain Polarization Port-to-Port Isolation Front-ta-Back Ratio Electrical Downtilt Options MET RET VSWR Connectors Power Handling Passive Intermodulation RR65-18-VDPL2/-R DualPol@ Polarization 1850 MHz. 1990 MHz 650 6.20 ~ 14.5 dB 17.0 dBi (14.9 dBd) Dual Linear Slant (:t 450) ~ 30 dB > 35 dB 20 - r Variable 10 Increments 0.10 Increments 1.3:1 Max 2; 7-16 DIN (female) 250 Watts CW ::; -150 dBc [2 x 20 W (+ 43 dBm)] Chassis Ground Lightning Protection Mechanical Specifications Dimensions (L x W x D) 56 in x 8 in x 2.75 in (142 cm x 20J cm x 7.0 cm) 150 mph (241 km/hr) 11ft' (.29 m') 92 Ibs (409 N) MET: 311bs (139 N); RET: 3151bs (150 N) MET: 13.51bs (6.2 kg); RET: 15.51bs (7.1 kg) Rated Wind Velocity Equivalent Flat Plate Area Front Wind Load @ 100 mph (161 kph) Side Wind Load @ 100 mph (161 kph) Weight (Without Mounting Kit) Mounting Options MTG-POO-10, MTG-S02-10, MTG-DXX-20', MTG-CXX-10', MTG-C02-10, MTG-TXX-10' RET Actuator Assembly I~I Cobra ™ MET/RET OptiRange ™ Suppressor™ I 42" J Note: RR65-18- VDPL2 represents MET; RR6S-18- VDPL2-R represents RET Note: 'Model number shown represents a series of products. See Mounting Options section for specific model number. Patterns Azimuth Elevation 20 Downtilt Elevation 30 Downti1t Elevation 40 Downtilt Elevation 50 Downtilt Elevation 60 Downtilt Elevation r Downtilt EMS' antennas are protected by one or more of the following U.S. patents: 5.844.529; 6.067.053. 6,462.710: 6.392.600; 6.069.590: 5.966.102; 5.757.246 EMS' antenna deSIgns may also be covered by pending U.S. patent applications and by pending & awarded International patents. Revised 4/27/04 .. +1 770.582.0555 ex! 5310' Fax +1 7707290036 www.emswlreless.com - - ~ :-"] ;--- - - 01 ~ """ 0_ o ;.;;, "',,- ~: tr: 17;~ <II.r~ I -~-'~ ,kj - ~ -- '. a. ~. ~ ~ ~ // THE.CITY.OF THE.CITY o F COPPELL ..~..* .. ? ~ E: q .t I\.s . \ eo CITY OF COPPELL 2nd ORe REPORT COPPELL .~J. .... ? ~ ~ .t 1\ 5 \ t'l q Proiect 10 Address SUP-06-0037 Proiect Name S-1236-A, Metropcs E Belt Line Rd Proiect Type Application Date Case Manaaer Proiect Description Special Use Permit 7/20/2006 Gary Sieb S-1236-A, MetroPCS, zoning change request from A (Agriculture) to S-1236-A (Special Use Permit-1236-Agriculture), to allow for a wireless communication antenna to be mounted to an existing electric transmission tower, with an accessory cabinet with enclosure at the base of the tower, located approximately 1,700-feet southwest of the intersection of of 1 AQency Engineering Comments 1. More information is needed on the "15' access easement". . Where does it connect? . What is the driving surface (must support emergency apparatus)? . Have you acquired the easement? The property belongs to the Riverchase HOA. 2. What utilities are proposed in the 5' utility easement? There does not appear to be a corresponding utility easement on the adjacent lot. P~ECTINFORMAnoN SCOPE a WORK: SITE AODRfSS: UNMANNED TEUCOtrMllUNlCATIONS fACILITY INTERSECTION Of BEL TUNE a: YocARTHIJR COPPEll. TX 75019 Jr 57' 13.8V" N 86" 57' 37.46" W CtlY or COPPEU.. D.tU.AS COUNTY, TEXAS TEL.[COMMUNlCAllONS FACILITY TELECOMUUNICATlONS fACILITY DRAWING INDEX 'l1Tta IHIE1' IIIITAlL IllI! I'\NI IUYA~.~" LATTTUD€: LONCfTUOE: JURISDICTION: EXtS11NC USE; PROPOSED USE: - -- -- NOTES AlE DOCUMENT REVIEW STATUS ACCEPTED - WITH IIHNOR OR NO COtAIENTS. CONSTRUCTMJN ~y PROCEED NOT ACCEPTED - Pl.EASE RESOLVE CClUWENTS N<<) RESUBMIT ACCEPTANCE DOES NOT CONSTITUTE /IPPRfItIAL. or DEStGN DETAILS. CAl..CtA.ATIOHS, AHAlYSlS. TEST METHOOS OR MATERW..S 0E:VEl.0PED OR SEL[CT[D BY SU8CONTRACTOft Nt) DOES NOT REUEVE SU9CONTRACTOR FltOW fUll COIlIPt.W<<;E wrTH CON1'RACl\JAL OBUGATION. [MG. CONST. REVIEWED: BY, DATE: REDUNE DRAWING REVIEW -(PRINT) SIGNATURE 00\T!: GENERAl. CONTRACTOR - CONFIRM ACCURACY OF' THESE REOUNE DRAWINGS NAME (PRINT) SIGNATURE 04TE FlElD ~TOR - VERIFY INSTAlLATION PER RtOUNE DRAWINGS -(PRlIIT) 00\T!: LANDLORD INFO APPROVALS TOWER OWNER: TXU SITE NAME: NORTHLAKE - RENNER SITE HUllerR, 13H/ 9W/ T311 LOCATION, COPPELL. TEXAS HEIGHT Of TOWER, 10,0' METROPCS: DATE: LANDLORD' OATL metroPCS o REV I I I SITE NUMBER I MPCS272 (DFW272) SITE NAMEI V ALLEY RANCH TXU - ZONING SET V1CINIlY MAP APPUCABLE BUILDING CODES AND STANDARDS DIRI!C1IONI: FROM DAllAS; TAKE 1-635 WEST TOWARDS IRVING. TAKE tHE hklcARTHUR EXIT AND HEAD NORTH TO BElTUNE. SITE WILL 8[ LOCATED AT THE NORTHWEST CORNER OF THIS INTERSECTION BEHIND SHOPPING corTER. SUBCONTRACTOR'S WORK SHALL COMPLY WfTH All APPUCABLE N.t.TK>NAL. STATE. AND lOCAl... CODES AS A:>OPTED BY THE lOCAL ,t,lrn..ORrTY HA.V1NG JURISDICTION (AHJ) FOR THE SfTE ~~g~~~~~o~f ~~gpi~D~D~~~~~~~~ ~O E~~I~ ~T~~~C00E5. C CONTRACT AWARD SHALL GovtRN THE CONSTRUCTION. SUBCONTRACTOR'S WORK SHALL caMPI. Y WITH THE LATEST EOfTlON or THE fOLlOWlNC STANDAADS. AMERICAN CONCRETE INSTITUTE ("Ci) :318, BUILDING CODE REQUIREMENTS fOR STRUCTURAL CONCREl[ AMERICAN INSTfTl;'T OF STEH CONSTRUCTION (A1SC), MANUAl... or STEEL CONSTRUCTlOH, ASD, NINTH EDITION TElECOMMUN:CATlO~S INDUSTRY ASSOC1A.TION (TIA) 222-f, STRUCTURAl. STANDARDS fOR STEEL ANTENN~ TOWER AND ANrENHA SUPPORTING STRUCTURES. TIA 607, COMldERCw.. BUILDING GROUNOI~ ....0 BONDING REQlJIR(MENTS fOR TELECOMMUN CATIONS INSTITUTE FOR ELECrRlCAl AND ElECTRON!CS ENGINEERS (IEEE) 61, GUtOE fOR t.lEASURlNG RESISTIVITY, GROUND IMPEDANCE, AND EARTH SURFACE POTENTIALS Of A GROUND SYSTrt.l IEEE 1 1 00 RECOMt.lENOED PRACTICE FOR POWERING AND GROUNDING Of ELECTRONIC EQUIPMOH IEE[ C62.41, RECOMMENDED PRACTICES ON SURGE VOLTAGES IN LOW VOLTAGE /II; POWER CIRCul'""S (FOR lCY'..ATION CATEGORY .C3" AND ~HIGH SYSTEM EXPOSURE") TflCORD!A GR-1275, GENERAl INSTAlJ\TION REOUIREt.4ENTS TElCOROiA CR-150.J, COAXw... CABLE CONNECTIONS B ANSI T111 ~. fOR TELECOM - DC POWER SYSTEt.lS - TELECOM, ENVlRONWENTAL PROTECTlON FOR ANY CONFliCTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS R€CAROINC; MATERW., l,4E.1HDOS or CONSTRUCTiON, OR OTHER REOUIREt.lENTS. THE MOST RESTRICTIVE REQUIREWENl SHALL GOVERt'. WHERE THERE IS CONFLICT BETWEEN A GENERAl REQU!RE""ENT AND A SPEClflC REQUIREMENT, THE SPEc:nc REQUIREIrA(NT SHALL GOVERN. A VALUY lIAHCH.lXlJ lITE NO. MPC8272 (DFWZ72) INTERSECTlON Of snTUNE If WacARTHUR COPPEu... TEXAS 75018 metroPCS' nw6J"CS 4 3 ~ It - NORTH ARROW LEGEND c::J EXISTING EOUI'UENT c:J PROPoSED EQUIPMENT [::J FUTURE EQUlPMOO' ~ EXIST. CABlE TRAy _ NEW CAaE TRAY CONDUCTORS AND RACEWAY TO BE FURNISHED . INSTAUm BY SUllCONTRACTOR J=l1-1 I ='-===-"'-.=Il~~ ~ 8 , , , / , , , / , , , / , , , / PROPOSED LUCENT BATTERY EW;K-up ON PROPOSED STEEL PlATfORW PROPOSED l1TIUTY RACK PROPOSEO IS' -0. HIGH ~RY SCREENWAU PROPOSED 8'-0. X 10'-0. STEEL PlATF'ORM WAHUr. BY ASP OR APPROVED EOlJN.. PROPOSED CA8L[ BRIDGE <-.ox ,.' LONG.) PROVIDE DRIP LOOP AT BOTH ENDS or PROPOSED C(W( CA8l.E (m>.) EXISTlNG l04.J't HIGH YOLTAC[ LATTICE TRANSMISSION TOWER PROPOSED POWERMOl/NT F()lJND\TION DESIGN PRCMOED BY OTHERS. PROPO$[O POWERYOuNT PROvIDED BY fW1', INC. CENF'RA.I Nn~' THE ACCESS EASEMENT CONNECTS TO THE PU8UC ACCESS fASEMENT ANO FlAt I..AHl OF THE SHOPPtNC CENTER IN THE COPPEU CROSSING AOOITION. THE UTIUTY EASEMENT DOES NOT PROTRl)[)[ INTO Nff AO...W:ENT lOT. WETROPcs UTILITIES RUN TO THE POWER POlE AT THE EDGE Of' THE ACCESS EASEMENT, o MlJRE LUCENT EQUIP. CA8INET ON PROPOSED 'l... PlATFORM . pROPOSfij lUCDlT EQUIP. .. ~ ~ PI.A~6:.0P0SEQ.. '" ....... ~ ................ ~PROPOSEO PAIR "-0. 'MOE ....... '" DECORATM METAL GATES REF. 3/AD3 c .......... ........... .......... ............, PROVIDE PROPOSm 6- THICK ...... ..... CRUSHED STON[ SURfACE OYER "'..... ,~~:~~l.EASE AREA WITH HER8ICm AFTER CONSTRUCTION IS COMPUTE '..... .......... -...... ......................... ...........- ........... ...........- ........... ........... - ............ ................ ............ .......... ................ CONTRACTOR TO PRCMOE A 12 GA. SHEET METAl SHROUD AROUND EXPOSED COAX OUTSIDE Of'" SECURITY f'(NCE .......... ................. ........... ........... .......... ...........~ B ~AL liTE PLAN 1/.. _ "-0. - SC'AlE NOT[D APPLIES TO 22")(34" SHEET SIZE. If PRINT SIZE IS 11")(17., THEN ACTIJAL SCAlE IS ONE IWF or SCAlE NOTED. (EXAMPlE: 1/2" _ I' -0. B€COWES 1/4" . 1'-0. ON 11. X 17- SHEET SIZE). 1lfS NOT[ APPlIES TO AlL DRAWING SHEETS, A .1XU lDFW272l TUNE a: MacARTHUR 75019 metroPCS IIWlI.J'CS ISIUm roll' ZOlMCl MID OM: ....... ,. -.cD roll' a.IG _ OM: ....... IISlC rot ZOIlMl _ OM: IIEWW -.c roll' ZONIG .I!IIl IlIIC MVlfW ... - DDOoO)ft: IIID DETAIl 5rTE Pl.M .. 3 2 J=t~1 =.'I::I...._~ GATE LATCH WITH lOCK (FS) PROPOSED 6'-0. HIGH STUl SOUO DOUBLE GATES WITH PAINT F'1HtSH ~ ~ o PROPOSED ANTENfttS TO BE MOUNTED ON PROPOSED STANOOf'F WOUNTS REF'. OCT. 2/ADJ L~~NNAS o I .. I I ~ i " .... i I .ANTENNA HEIGHT SHOWN REPflESENlS DESlGll INTENT lIMED ON INf'ORIMTlOH FROM TH[ CLIENT. CAPACRY OF txu TOWER WITH PROPOSED POWERWOUNT TO BE VERlFlED WITH STRUCTLJR.At NW.. YSIS PROYOED BY REGISTERED PROfESSJONN.. OCNEER IN THE STATE or TEXAS. NO CONSTRUCTION StW.l PROCEED UN1'l. SAID AtW..Y'SlS ~ BEEN ~O BY TXU AND 'THE ENGINEER WHOSE SEAL IS PRESENT ON THESE CONSTRUCTION DRAWINGS. ~ GATE DETAL 3 1/2" _ "-0" J 12'-0" ~ CENF1W ~. -GATES TO BE PAINTED ....EOOIM GRAY WI DOU FlNISH" TO MATCH SMLAR GATES IN THIS NfrA. STNT TO BE PRCMDED WITH COLOR 8OMO OUftiNG PEAWIT APPtICATION PROCESS. c EXISTING 104.3'2; TXtJ HIGH YOlTACE TRAHSWISSlON TOWER B ,1 ~ ~ ~ ANTE...,. IlIOUNT SHOWN REPRESENTS DESICH INTENT BASED ON INf'ORWATtON FROM THE CUEHT. C>>JaN or TXU TOWER WITH PROPOSED POWERMOUNT TO BE 't"ERIf"IED WITH 5lRUCTURAI.. ANALYSrS PROVIDED BY REGtSTERED PROfESSIONAl ENGINEER IN THE stATE or TEXAS. NO CONSTRUCTION SHAlL PROCEED \..WTIl SAI) ANAlYSiS HAS BEEN APPROVED BY TXU AND THE ENGINEER WHOSE SEAL IS PRESENT ON THESE CONS1'RUCTION ORAWlMeS. PROPOSED POWERMOUNT PROYIOEO BY fWT, IHC. (12) PllOPOS(D 1 5/.- COAX TO BE ROUTED INSIDE POWERUOUNT TO PROPOSED ANTENNAS. WEATHERPROOF S c(w( fOR nJT\JRE USE. COAX CONNECTOR TO BE TERMINATED USING ANDR[W or -CAPKIT Ii! .. ;., : .. Ii! PROPOSED S' -0. HIGH IiMSONRY SCREEN WALL PftOPOSED UCHT WEIGHT ~ RING W/ (') 24" STAHD-DFT ARMS - (6) 2-3/8" 0.0. ANTENNA PIPES 84. lONG. 6 PROPOSED NETROPCS ANTENNAS YODEL 'RR85-18-WPl2-R: REF ATTACHED CUT-SHEET FOR ANTENNA IHF'ORMATJON ~A ORIENTATION ,. . 1'-0" A 6 2 .... IIIU[() ~ ZaMMG .. Ole ... 14 -.mFQll__OM:... ~ sac POll ZONIC ... DE ... IIIuBl fOIl zo.c IifiO DE .... .... -- IlDIllJiOI'r: CS IN ..._ IN ..._ IN ..._ IN ..._ " "" --- .. nWlAoF'CS metroPCS 4 3