CITY OF COPPELL
ORe REPORT
COPPELL
..~' *"" ""'..ljl
~ . Q
e or . \ ~ q
~ 8 .
" 8
Proiect 10
PO-06-0043
Proiect Name
Pd-216-h, Robertson Pools
Address 569 Coppell Rd
Proiect Tvpe Re-Zoning PO
Application Date 8/23/2006
Case Manaaer Matt Steer
Proiect Description zoning change request from Hand SF-12 (Historic and Single Family-12) to PO-216-H (Planned
Development-216-Historic), to approve a detail site plan to allow 1 ,740-square-foot expansion to an existing
4,850-square-foot building, construction of a 4,970-square-foot split face block building, outside storage and additional
1 of 2
Agency Reviewed By Review Date Comments
Building Inspection Greg Jones 8/28/2006 1. Our office has received complaints on the outdoor
porta-potty being used in view of the Loch Lane
neighborhood. Provision for indoor toilet facilities
needs to be accomplished with this approval.
2. Expansion to existing 4850 s.f. building will trigger
auto fire sprinkler requirement.
3. Split face block does not meet masonry definition.
Not allowed as primary 80% building material.
Electric and Gas Jeff Curry 9/1/2006 No Comments Received
Engineering Ken Griffin 8/31/2006 1. The masonry wall should not extend into Flood
Zone 'A'.
Fire Administration Tim Oates 8/31/2006
1. Commercial buildings over 5,000sqft are required
to be protected by automatic fire sprinkler systems.
Addition to existing building takes the building to
greater than 5,000sqft.
2. Proposed new building is greater than 150ft from
public right of way, therefore a fire lane will be
required. Fire lane shall be designed in accordance
with City Standards.
3. What is the aggregate capacity of the fuel storage
tanks?
4. Fire hydrants are required along the fire lane
easement at least every 300ft.
Parks and Recreation John Elias 8/30/2006 No comments.
THE.CiTY.OII"
COPPELL
~* "
" s
Agency
Planning Department
Reviewed By
Matt Steer
THE.CITY.OF
CITY OF COPPELL
DRe REPORT
COPPELL
~."...
1If *'...,.
~ . . Q
e q
..t J\ .s \ ~
Review Date Comments
8/31/2006 Site Plan:
1. List all proposed PD Conditions
(variances/exceptions to the H District zoning).
2. Include Site Data table as required by attached
checklist.
3. Include Lot 1 R, Block A Robertson Commercial
Pools in all title blocks.
4. Include parking space striping in the front of the
buildings.
5. Add Architect's contact information.
6. Show existing/proposed adjacent and on-site zoning
information.
7. Indicate different proposed uses for large asphalt
area.
8. Show refuse facilities and mechanical equipment,
including height, materials, and elevations of
proposed screening.
9. Include all existing/proposed lighting facilities, and
ensure they're in accordance with the H District
regulations.
10. Change "Planter" note to "Landscape Island" on
drawing.
Landscape PlanlTree Survey & Irrigation Plan:
1. Change title block to read "Landscape Plan/Tree
Survey".
2. Recommend saving the 32" Post Oak in the rear of
the property.
3. Include a Landscape Data table as required by
attached checklist showing required/provided
trees/shrubs and square footage for each category.
4. Include only on-site trees in tree calculations.
5. Show Plant legend.
6. Indicate trees to remain and those to be removed
within the tree survey chart.
7. Include an irrigated overstory tree within each
landscape island.
Elevations:
1. Include entire structure with existing and proposed
stone pattern.
2. Accessory structures shall be compatible in design,
shape, materials, and roof shape and shall reflect the
general character of the primary building.
3. Include elevations of proposed masonry wall
depicting height, column spacing and materials.
4. Submit color board with materials and color
elevation at DRC.
THE.CITY.OF
THE-CITY.OF
CITY OF COPPELL
2nd ORe REPORT
COPPELL
~.... ~" ...~ ,-", ~. 4?
.".. ','. . ~ '* flj,"" , .!f
/ 1:' ~-,- ; ^a,,~ q ,,'
-\' 1\ f:" \ '(',
Proiect 10
PO-06-0043
Proiect Name
Pd-216-h, Robertson Pools
Address 569 Coppell Rd
Proiect Type Re-Zoning PO
Application Date 8/23/2006
Case ManaQer Matt Steer
Proiect Description zoning change request from Hand SF-12 (Historic and Single Family-12) to PD-216-H (Planned
Oevelopment-216-Historic), to approve a detail site plan to allow 1, 740-square-foot expansion to an existing
2,783-square-foot building, construction of a 4,970-square-foot split face block building, outside storage and additional
of
Aqency
Engineering
Comments
No Comments