Loading...
Departmental comments THE,CITY.OF COPPELL ~".""'.... . ."* .lJL ~ . ~ e J( . I & q ~ s . THE.CITY.OP' CITY OF COPPELL ORe REPORT COPPELL ..~"* . .. ~ ~ e J( . I & q ~ 6 . Proiect 10 SUP-07-0010 Address 769 S MacArthur Blvd 233 Proiect Name S-1239-c, Camp Bow Wow Proiect Type Special Use Permit Application Date 2/14/2007 Case Manaaer Matt Steer Proiect Description from C (Commercial) to S-1239-C (Special Use Permit-1239-Commercial) to allow a 6,484-square-foot kennel with a screened 3,900-square-foot outside play area, at the request of Amy Petrie and Linda Grady. Agency Building Inspection 1 of 2 Review Date Reviewed By Greg Jones 2/21/2007 Electric and Gas Engineering Fire Administration Parks and Recreation Jeff Curry Ken Griffin Tim Oates John Elias 2/22/2007 2/19/2007 2/21/2007 2/19/2007 Comments 1. How is pet waste in play yard/outdoor area handled with regards to public health and sanitation issues? Currently parking lot surface drains into storm water collection system. Provisions need to be made to dispose waste/effluent into sanitary sewer system, but introduction of storm water not permitted into sanitary sewer, so would not be allowed to design outdoor 88 drain. No Comments Received No comments. No comments regarding the zoning change request. 1. Why do the trees need moved? THE.CiTY.OF COPPELL " s Agency Planning Department Reviewed By Matt Steer THE.CITY.OP' CITY OF COPPELL ORC REPORT COPPELL ....~il * fi~. ~ ;-~~ e .\' "s . \ & q Review Date Comments 2/21/2007 Site Plan & parking: Include chart with all tenant names, square footage, and required parking in chart on site plan. 10 spaces is a major reduction to the 32 spaces required at a retail ratio of 1 parking space per 200 square foot. You are also reducing the total parking count by 11 with the conversion to an outdoor play area. According to the calculations submitted, there are still 23 extra parking spaces in the overall development (calculating each business at a standard parking ratio, including vacant spaces, but not including your business). Please include the reasoning behind having only 10 spaces for this use. Note on Site Plan under hours of operation that no overnight boarding will take place outdoors. Landscaping: Transplanting should be done at a time when deemed appropriate by a landscape architect. Drive into former parking area should be converted to landscaping. Trees should be identified as being relocated and additional shrubs noted along proposed wall. Elevations: Indicate materials of proposed wall on elevations. Top of the proposed wall shall match existing cap found on buildings. Total signage shall be less than or equal to the width of the lease space in square footage (96 SF total) and shall be white to match the other signage in the center. The raceway shall match the brick color.