ORe REPORT
Proiect 10
SUP-07 -0013
COPPELL
1f~* "" ..
r ~
e <l' <\ \ ~ q
& .
Address 881 S Denton Tap Rd
Proiect Name
S-1215r, Kountry Donuts & Cafe
Proiect Tvpe Special Use Permit
Application Date 2/14/2007
Case Manaaer Matt Steer
Proiect Description zoning change request from C-S-1215 (Commercial, Special Use Permit-1215) to C-S-1215R (Commercial, Special Use
Permit-1215-Revised), to allow a 1 AOO-square-foot restaurant with drive-through service on 0.49 of an acre property
1 of 2
Agency Reviewed By Review Date Comments
Building Inspection Greg Jones 2/21/2007 1. Building will need to be equipped with a Type I
grease hood at cooking areas.
2. Use shall require installation of a min. 750 gallon
grease interceptor.
Electric and Gas Jeff Curry 2/22/2007 No Comments Received
Engineering Ken Griffin 2/19/2007 1. It appears that an attempt to submit a complete set
of plans was made by the engineer. Please be
advised that plans submitted with DRC does not
constitute plan submittal. Plan submittal will only be
accepted after some approval has been obtained
through the Planning and Zoning Commission and/or
City Council.
Grading, Paving and Drainage Plan
2. It appears that you are discharging your site runoff
through the opening for the walk way from the
sidewalk. Please be advised all drainage must be
picked up on site and discharged to a system.
Utility Services Plan
3. There is no need to sawcut Denton Tap Rd. to tie
into an 8" water line that was abandoned in 2005.
There is currently two 8" stubouts to this property off
the new 16" water line that was built in the median of
Denton Tap Road in 2005. One stubout is about 20'
south of your north property line and one stubout is
about 100' south of your north property line. The
existing 8" stubout approximately 100' south of your
north property line will conflict with the proposed
location for your new sewer line to be bored across
Denton Tap Rd. There needs to be a minimum 9'
separation between the 8" stubout and the proposed
sanitary sewer service line.
Fire Administration Tim Oates 2/22/2007 1. Show existing and proposed fire hydrants. Minimum
of one fire hydrant may be required on this parcel.
Parks and Recreation John Elias 2/19/2007 No comments.
THE.CITY.OPO
COPPELL
Agency
Planning Department
Reviewed By
Matt Steer
CITY OF COPPELL
ORC REPORT
THE.CITY.O,..
Review Date Comments
COPPELL
.~~ * jJ~.
~ ;-~Q
e ..t J\ & . \ &0 q
2/21/2007 Site Plan:
1. Increase size of Site Plan and decrease size of
handicap details.
2. Remove landscape hatching from the Site Plan.
3. Place landscaping area calculations on Landscape
Plan. Remove from Site Plan.
4. Explain- "Off Site Vehicular paving."
5. FAR = .07:1
6. Review standard "Site Data Table" requirements
found within the attached checklist.
Elevations:
1. Monument sign shall be 4' X 10' maximum
dimensions (not 6' X 5.5')
2. Screening wall details shall match the bloom embro
screening wall.
Landscape Plan:
1. Ensure all 17 trees are overstory or if accent trees
needed, then 3 accent trees = 1 overstory tree. Revise
landscape plan accordingly.
2. Ensure property owner to north grants permission for