Loading...
DRC Comments PD THE-CITY-OF COPPELL ..~.... * .. .. ~. . 0 ex" ,&q 8 - THE-CITY-OF CITY OF COPPELL ORC REPORT COPPELL ..~~ * ~~.. ~ ~~o e .t 1'\ S . \ e:. q Proiect 10 Address PD-O? -0040 Proiect Name Pd-221r2-hc, Duke Lesley Addition, Proiect Tvpe Re-Zoning PO Aoolication Date 5/23/2007 Case Manaaer Gary Sieb Proiect Description zoning change request from PD-221-HC (Planned Development-221-Highway Commercial) to PD-221R2-HC (Planned Development-221 Revision 2-Highway Commercial) to attach a Detail Site Plan to allow for the construction of an 18?,535-square-foot, six-story hotel, with 260 rooms and ancillary uses, 1 of 1 Agency Reviewed By Review Date Building Inspection Greg Jones 5/31/2007 Electric Jeff Curry 5/31/2007 Engineering Michael Garza 5/30/2007 Fire Administration Tim Oates 5/29/2007 Parks and Recreation Planning Department John Elias Gary Sieb 5/30/2007 5/25/2007 Comments 1. No comments on zoning change. No Comments Received No comments. 1. Extend fire lane around the building. 2. Relocate fire hydrants adjacent to the building to the other side of the fire lane. 3. FDC shall be within 50ft of a fire hydrant and on the same side of the fire lane. 4. Fire hydrant dead-ends not to exceed 150ft. 5. Where is the loading zone? NE corner? Parking in fire lanes is prohibited. No comments. SITE PLAN 1. Insure all landscape islands contain at least 150 square feet of I.s. 2. Parking for restaurants is 1/100 sq. ft. Explain note regarding restaurant parking. 3. State width of landscaping on west side adjacent to Point West Blvd. 4. Is 3.5 foot sidewalk wide enough for pedestrian traffic? 5. Indicate total square footage of hotel in footprint of building. LANDSCAPE PLAN 1. Justify 7000 square foot landscape shortage. 2. Explain "mini-landscaped islands" containing Bald Cypress trees. ELEVATIONS 1. Indicate size and square footage of signage on East, West, and South elevations. 2. It appears East and West elevations are reversed. 3. A colored drawing/elevation would be helpful in explaining this request. 4. Provide color board showing building materials/colors. 5_ Need detailed drawings of size, location, construction materials of monument signage. Memorandum ~R Date: June 7. 2007 To: Marcie Diall\ond ~c: From: Jeff Curry Subject: May ORe S-1241-C, Fat Daddy's Burger House - zoning change acceptable, please contact Larry Redick at 972.323.8917 to discuss electric service requirements. Northlllke Woodlllnds Center, Lot 4, Block A, Minor Plat - plat unacceptable, please contact Larry Redick at 972.323.8917 to discuss electric easement requirements. PD-228-SF-9, The Chateaus of Coppell- zoning changc acccptable, please contact Jeff Curry at 972.888.1330 to discufls electric service requirements. Arbor Manor, Preliminary Plat - plat unacceptable, pl~ase eontact Jeff CUTTY at 972.888.1330 to discuss electric easement requirements. ,PD-2211U-HC, Duke Lesley Addition - zoning change acceptable, please contact Jeff Curry at 972.888,1330 to discuss electric scrvice requirements. Duke Lesley Addition, Lot 2R Block C, Replat - plat unacceptable, please contact JetI' Curry at 972.888.1330 to discuss eascmcnt requirements. PD-221R3-HC, Duke Lesley Addition - i',oning change accep(ahle. please contact Jeff Curry at 972.888.1330 to discuss electric Sl;:rvi<.:e requirements. 1lD-222R-LI, Duke Lesley Addition - zoning change acccptable. please contact Jeff Curry at 972.888.1330 to disl;USS electric service requirements. Duke Lesley Addition, Lot I, Block AI Final Plat - plat unacceptable, please contact Jeff Curry at 972.888.1330 to discuss electric easement requirements. Bethel Business Park, Lot 1, Block A, Site Plan - site plan acceptable, please contact Jeff Curry at 972.888.1330 to discuss clectric service requirements_ Bethel Business Park Lot 1, Blo.:k A, Minor Plut - plat unacceptable, please contact Jeff Curry at 972.888.1330 to discuss electric easement requirements. CONFIDENTIAL ~>2'd 260L t.>m: 2L5: 01 t.>0n8882L5 ^~3nIl3a J3l3 nXl:WO~j 8~:t.>1 L002-L0-Nnr