Loading...
DRC Comments THE.CiTY.OF THE.CITY.OF COPPELL .~* ... r ~ e q .t ~ s . \ & CITY OF COPPELL ORe REPORT - COPPELL .~* f. ... r ~ e q ..t "s . \ & Proiect 10 PD-07 -0052 Address 750 Coppell Rd Proiect Name PD-108r8-h, the Village At Old Coppell Proiect Type Re-Zoning PD Application Date 6/22/2007 Case Manaaer Matt Steer Proiect Description to attach a concept plan for seven lots on approximately 10.4 acres and a detail plan for two 21,050 sq. ft, 2-story retail/hotel buildings on two 1.15 acre lots. a 25.141 sq. ft, 2-story evenUconference center on a 2,8 acre lot. and a 7,812 sq. ft pet bed/breakfast on a 1.04 acre lot. 1 of 3 Agency Reviewed By Review Date Building Inspection Greg Jones 6/28/2007 Electric Jeff Curry 6/28/2007 Engineering Michael Garza 6/28/2007 Fire Administration Tim Oates 6/27/2007 Parks and Recreation John Elias 6/26/2007 Planning Department Matt Steer 6/28/2007 Comments 1. No comments Contact Larry Redick at 972-323-8917 to discuss electric service requirements. 1. Show existing 8" waterline to the Service Center. 2. Plat, utility plans and site plans do not match, 3. "Road B" - make it a fire lane and access easement. 4. There should be 20' utility easements for all public utilities. 5. If no pond, provide adequate drainage system design for the 1 OO-year conveyance. 6. The pond appears to be discharging onto future Service Center road; it can not discharge onto Coppell property , 7. There is an 8" waterline existing on the north side of the property. 8. A building cannot be placed over utilities, 9. A property owner's association document is needed for maintenance of utilities on private property. 10. Access Road "A" is not R.OW, dedication, it is part of the Service Center property, 1, Show proposed and existing fire hydrants and fire department connections on the Site Plan, 1. Tree Removal Permit will be required prior to start of construction, Tree Retribution will not be required based on plans submitted June 20,2007. Site Plan: 1. Front yard setback within the H District is measured from the edge of pavement. There is 9.5' from the edge of future angled parking to property line; therefore, 5.5 - 15,5' is needed from new right-of-way line. 2. In Site Data tables for each lot, change existing zoning to PD-108-H, PD-108R5-H and H; add "proposed use" and add "proposed zoning", 3. Minimum parking space dimension is 9' X 19' unless where abutting a sidewalk or landscaping, then it can be reduced to 9 X 17', provided that 2' is added to the landscaping. 4. Ensure all property lines of all plans match, Include property lines and easements with bearings and distances. 5. Show Service Center parking area on plans and proposed screening mechanism (wall or landscaping). THE.CiTY.OF COPPELL ~."....r. ~ * .. ? Q e q ..t <"\ S . \ e, Agency Reviewed By -- THE.CITY.OF CITY OF COPPELL ORe REPORT COPPELL - " Review Date Comments 6. Two of the bench locations are located within right-of-way. Is this acceptable? 7. In Lot 7 Site Data Table, indicate that the floor area is representative of two 6,200 square foot buildings and that 23 of the proposed parking spaces are located within Lot 6. 8. Reduce width of drive aisles to 24'. 9. In Lot 6 Site Data Table, show the maximum number of dogs within the required parking tabulation, 10. In Lot 5 Site Data Table, change standard proposed parking spaces to 47 and total to 51 as shown in drawing, 11. Change bolded section of old property line to normal line width. 12. Within the parking count on Lot 4, change 54 to 52. 13. Show locations of all lighting, 14. Show details of all fencing, dumpster enclosures, benches, lighting, walls, gazebos, sign towers, water fountain, storage building, electrical court screening, etc... Refer to Old Coppell Design Guidelines, 15. Consider relocating the dumpster away from view from the entrance drive, and possibly relocating the "elect court" and "storage building". 16. Indicate existing land use and zoning of adjacent properties. 17. Ensure mechanical equipment is not located on the primary facades (those abutting Coppell Road). Show proper location and screening in rear. 18. Include the same hatching of event center on the other structures that are getting detail plan approval (Pet bed/breakfast and retail/hotel buildings), 19. Show fire hydrant and FDC locations and indicate turning radii for proposed fire lanes. 20. In Lots 2 & 4 Site Data Tables, Indicate that 4 of the proposed parking spaces are garage parking spaces. 21. Show decorative paving and/or brick pavers where proposed on plan and include detail. 22. In Lot 3 Site Data Table, show 117 parking spaces as standard and 2 as handicap. 23. Show dimensions of fire lane easement to the north. 24. Ensure title blocks of all plans show "Villages of Old Coppell". Within the title block of the site plan, include applicant within the contact information for Donna Kolberg and "Architect" in place of "Applicant" where it refers to Roger (Skip) Blake. 25. Correct Sheet numbers. 26. List PD Conditions on Site Plan. Landscape Plan: 1. Revise open space area and calculations per what is shown on Site Plan. 2. Landscaping shown as proposed within the Service Center property is acceptable to the City, but area cannot be included within calculations, 3. Ensure each landscape island contains one tree, THE.CITY.OF ---. COPPELL JJf~-.'_.'*~' . ~ -. 0 ~ q X ~.s . \ & Agency Reviewed By _. THE.CITY.OF CITY OF COPPELL ORe REPORT COPPELL ~~- ... * ~ ... ? - ~ ~ q ..t "".s . \ & Review Date Comments Where there are double rows of parking and a double island, show two trees. 4. Recommend replacing elaeagnus with abelia. 5. Ensure tree list matches what is shown on the tree survey. 6. Double check all calculations once plan revisions are made, Tree Survey: 1. Show correct property boundary and proposed site design. 2. Indicate which trees are "to remain" and which are "to be removed". 3. Consider combining the tree survey with the landscape plan. If done, then rename Landscape Plan to Landscape Plan/Tree Survey. Elevations: A color board is required to be submitted at DRC showing all materials of each building submitted for detail plan approval. A color rendering of each front elevation is helpful. 1. On all elevations, reconsider vinyl cladding window with a more traditional product. 2. On the Texas Belle Event and Conference Center: a. Include railing details, b. For durability and ease of maintenance, recommend replacing fiberglass columns, ballisters and stair railings with cast stone or other more suitable product. c. Replace EFIS with Portland Cement Stucco, d. Label all colors and materials to be used, 3. On the Hotel/Retail Sites: a. Ensure all shutters "fit the window" and awnings are fabric (no metal), b. Include details for garage doors, 4. On the Pet Bed/Breakfast Site: a. Indicate materials and colors and show an elevation for each side and rear. 5, Include a Miscellaneous Elevation Sheet: a. Show details of all fencing, dumpster enclosures, benches, lighting, brick walls, gazebos, sign towers, water fountain, storage building, electrical court screening, etc,.. Refer to Old Coppell Design Guidelines. ,i,~... ~ . ADD 2001 >lje~ PI feet I.BLAKE ARCHITECTS 1202 S. White Chapel Road . Suite A SouflUake, Texas 76092 · 817~-9397 August 1, 2007 City of Coppell PlanningI>epanmnent Matt Steer 255 Parkway Blvd. Coppell, Texas 75019 RE: The Village at Old Coppell Comments & Response Comment 1: Revise elevations of the event center to show Portland Cement Stucco in place ofEFIS, and accurately label the window surrounds (cast stone not being proposed), re-Iabel the "vinyl windows" to "vinyl windows with external mullions", and label the decorative metal railing at the front and rear of the building. Response: AU labels changed. Metal railing removed from front and rear of building. Comment 2: Correctly label all materials and colors to be used on black and white elevations and garage door materials. Response: All materials labeled. Comment 3: Ensure all buildings have a brick veneer at the foundation. Label on each elevation. Response: All buildings have brick or stone veneer at foundation and are labeled accordingly. Comment 4: Revise Pet Bed and Breakfast black and white elevations to show all materials and colors, accurately depict the brick wall adjacent to the structure, and reorient the page. Response: Pet Hotel B&B elevations revised to show all materials and colors. Brick waD to match brick waD elevation shown on elevation details sheet (along with gazebo, sign tower, etc.) The wall will be made out of the same brick materials as used on Pet Hotel B&B itself. In order to fit all 4 sides with page "reoriented" a new sheet was created. Comment 5: Revise Sheet 7 to accurately depict all fencing, dumpster enclosures, benches, lighting, walls, gazebos, electrical court screening, etc. Refer to the Old Coppell Design Guidelines. Response: Sheet 7 Revised. The gazebo, sign tower, and brick waD elevations were moved to sheet 4 in order to show proportion of these elements in relation to the size of the hotel/retail facilities. Comment 6: Coordinate with the Fire Department for proper FDC and fire hydrant locations and indicate on Site Plan. Response: Fire Hydrant locations shown. Comment 7: Details for the benches and lighting will need to match what has been approved for the Bethel Road project and the benches along Coppell Road will need to be coordinated with the Engineering Department for relocation after Coppell Road is improved. Response: During P&Z Council it was mentioned that whoever builds first will select benches. Samples of benches attached. Owner willing to work with city on which style they prefer. Comment 8: Show dimensions of depth of the double row parking (19' required) and depict two trees within each double island. If 18' is proposed, this will need to be listed as a PD Condition on Site Plan). Response: Double row parking dimensions shown. Spaces meet 19' depth requirement. Comment 9: Label the 6-8' brick wall around the exercise yard of the pet bed and breakfast. Response: Brick wall labeled and detail shown. Comment 10: Include all bearings and distances of all property lines and include all existing and proposed easements accurately labeled. Response: Site Plan revised to show distances and bearings of property lines. Comment 11: List the PD Conditions on the Site Plan (perimeter landscaping exception and detached sign exception). Response: PD Conditions listed on Site Plan. I.BLAKE ARCHITECTS 1202 S. White Chapel Road . Suite A SoufrUake, Texas 76092 · 817-488-9397 July 10, 2007 ~ ; JUL 2007 Revised P&Z City of Coppell Planning Department Matt Steer 255 Parkway Blvd. Coppell, Texas 75019 RE: The Village at Old Coppell Comments & ResDonse SITE PLAN Comment I: Front yard setback within the H District is measured from the edge of pavement. There 9.5' from the edge of future angled parking to property line; therefore, 5.5 - 15.5' is needed from new right-of-way line. Response: Front setback adjusted. Comment 2: In Site Data tables for each lot, change existing zoning to PD-I 08-H, PD- 108R5-H and H; add "proposed use" and add "proposed zoning". Response: All tables updated to show changes. Comment 3: Minimum parking space dimension is 9' x 19' unless where abutting a sidewalk or landscaping, then it can be reduced to 9' x 17', provided that 2' is added to the landscaping. Response: Parking space dimensions adjusted. Comment 4: Ensure all property lines of all plans match. Include property lines and easements with bearing and distances. Response: Comment 5: Response: ~ 'JUL 2007 Revised P&Z Show Service Center parking area on plans and proposed screening mechanism (wall or landscaping). Service center parking labeled & landscaping shown. Comment 6: Two of the bench locations are located within right-of-way. Is this acceptable? Response: Said to be acceptable during review meeting - benches to remain in right-of-way. Comment 7: In Lot 7 Site Data Table, indicate that the floor area is representative of two 6,200 s.f. buildings and that 23 of the proposed parking spaces are located within Lot 6. Response: Lot 7 Data Table updated to show (1) 6,200 s.f. building & (1) 7,000 s.f. building. 23 spaces shown to be in Lot 6. Comment 8: Reduce width of drive aisles to 24'. Response: All drive aisles reduced to 24'. Comment 9: In Lot 6 Site Data Table, show the maximum number of dogs within the required parking tabulation. Response: Table updated to show 2 dogs per suite at 39 suites equals a maximum number of 78 dogs. At 10 dogs per parking space, 8 spaces would be required. Comment 10: In Lot 5 Site Data Table change standard proposed parking spaces to 47 and total to 51 as shown in drawing. Response: Table updated. Comment 11: Change holded section of old property line to normal line width. Response: Line changed. Comment 12: Within the parking count on Lot 4, change 54 to 52. Response: Parking count remains the same. We were unable to determine why "54" should be "52". ~ r JUL 2007 Revised P&Z Comment 13: Show locations of all lighting. Response: Lighting shown. Comment 14: Show details of all fencing, dumpster enclosures, benches, lighting, walls, gazebos, sign towers, water fountain, storage building, electrical court screening, etc. Response: New sheet with all detail elevations added. Comment 15: Consider relocating the dumpster away from view from the entrance drive, and possibly relocating the "elect court" and "storage building". Response: All structures to remain in the same location as discussed in meeting. Comment 16: Indicate existing land use and zoning of adjacent properties. Response: Land use and Zoning indicated. Comment 17: Ensure mechanical equipment is not located on the primary facades (those abutting Coppell Road). Show proper location and screening in rear. Response: All mechanical to be out of view on building rooftops. Comment 18: Include the same hatching of event center on the other structures that are getting detail plan approval (Pet BedIBreakfast and Retail/Hotel buildings). Response: Pet Hotel and Retail Hotel Buildings hatched. Comment 19: Show fire hydrant and FDC locations and indicate turning radii for proposed fire lanes. Response: Hydrants, FDC and turning radii indicated. Comment 20: In Lots 2 & 4 Site Data Tables, Indicate that 4 of the proposed parking spaces are garage parking spaces. Response: Garage spaces indicated. Comment 21: Show decorative paving and/or brick pavers where proposed on plan and include detail. Response: Areas to be decoratively paved are cross-hatched on site plan. Comment 22: In Lot 3 Site Data Table, show 117 parking spaces as standard and 2 as handicap. Response: Parking spaces corrected. 4~ J/Jt R,.- Comment 23: Show dimensions of fire lane easement to the north. .J Response: All dimensions indicated. Comment 24: Ensure title blocks of all plans show "Villages of Old Coppell". Within the title block of the site plan, include applicant within the contact information for Donna Kolberg and "Architect" in place of "Applicant" where it refers to Roger (Skip) Blake. Response: Title blocks updated to show proper information. Comment 25: Correct sheet numbers. Response: Sheet numbers corrected. Comment 26: List PD conditions on Site Plan. Response: PD conditions eliminated through discussion during meeting. No further conditions to list on Site Plan. ELEVATIONS Comment 1: On all elevations, reconsider vinyl cladding window with a more traditional product. Response: Bringing sample of window type for approval. Comment 2: On the Texas Belle Event and Conference Center a. include railing details b. For durability and ease of maintenance, recommend replacing fiberglass columns, ballisters and stair railings with cast stone or other more suitable product. c. Replace EFIS with Portland Cement Stucco. d. Label all colors and materials to be used. Response: a. Railing sample provided. b. Rather than fiberglass or cast stone we are proposing using Worthington perma-cast for all columns, ballisters and railings on the Texas Belle Event and Conference Center. These products are ~ r ~ JUl 2001 Aetlised p&z made from durable polyester resin that are "virtuaOy maintenance free". (www.worthine:tonmillwork.com). c. No EFIS on structure. d. Colors and materials labeled. Comment 3: On the Hotel/Retail Sites: a. Ensure all shutters "fit the window" and awnings are fabric (no metal). b. Include details for garage doors. Response: a. Shutters removed where they do not "fit the window" and all awnings are fabric. b. Garage door sample to be provided. Comment 4: On the Pet BedlBreakfast Site: a. Indicate materials and colors and show an elevation for each side and rear. Response: ColorslMaterials indicated and all four elevations shown. Comment 5: Include Miscellaneous Elevation Sheet Response: Miscellaneous Elevation Sheet Included r-i I- L_ ~. --, ,- ' ..i~ L~___ C& P ~n1!B~!rillg~~~l(' . engineering . surveying . construction management . traffic . planning ~ ;~llL 2001 Qa .. :'>t;a P&l July 9, 2007 City of Coppell Planning Department Matt Steer 255 Parkway Boulevard Coppell, Texas 75019 RE: THE VILLAGE AT OLD COPPELL 10.9 ACRE TRACT COPPELL, TEXAS Comments & Response I. BUILDING INSPECTION Greg Jones Comment 1: No Comments Response: General Comments II. ENCORE ELECTRIC 1015 Hutton Carrollton, Texas Jeff Curry Comment 1: Contact Larry Redick at 972-323-8917 to discuss electric service requirements. Response: Contact Larry Redick at L.redick@encore.com. Requested preliminary information to be sent. III. ENGINEERING Michael Garza Comment 1: Show existing 8" waterline to the Service Center. Response: We have shown existing 8" Water Line, which will be relocated. Comment 2: Plat, utility plans and site plans do not match. Response: We have coordinated all plans to match. 1801 GATEWAY 8LVD. SUITE 101 . RICHARDSON. TX 75080.972.644.2800. FAX 972.644.2817 Q :\F'ILES\COMMENTS _ REPONSES\VILLAGES _@_OLOCOPPELL.DOC L__~!fJBgl~_e ~_rlr!B~l t (_ . engineering . surveying . construction management . traffic . planning f " JUt 2007 Revised r6t.f. Comment 3: "Road B" - make it a fire lane and access easement. Response: We have revised plans accordingly. Comment 4: There should be 20' utility easements for all public utilities. Response: We have provided appropriate Fire Lane and Utility Easements. Comment 5: If no pond, provide adequate drainage system design for the 1 DO-year conveyance. Response: We have revised our Preliminary Drainage to reflect 100 year conveyance with a Storm Sewer Discharge to the existing Creek to the East. Comment 6: The pond appears to be discharging on to future Service Center Road; it can not discharge onto Coppell property. Response: The System will discharge past the proposed drive and then grade-to-drain to the existing Creek. Comment 7: There is an 8" waterline existing on the north side of the property. Response: We have shown the existing 8" Water Line. Comment 8: A building cannot be placed over utilities. Response: We are abandoning and relocating existing utilities. Comment 9: A property owner's association document is needed for maintenance of utilities on private property. Response: A proper B.O.A. document will be provided prior to the Final Platting of the property. Comment 10: Access Road "A" is not R.O.W. dedication; it is part of the Service Center Property . Response: The proposed Roadway Service Center area has been revised, this area will be part of the Final Replat of the City of CoppeD Service Center. 1801 GATEWAY BLVD. SUITE 101 . RICHARDSON, TX 750BO. 972.644.2BOO. FAX 972.644.2817 41 :\F"ILES\CoMMENTS _ REPoNSES\VILLABES _@_OLD COPPELL. DOC - C & PEn gin e e r l~gL~Jt_ ' · engineering . saneying . construction management . traffic . p1anring " ~ 'JUl 2007 Ro\ .! .ut:a P&l IV. FIRE ADMINISTRATION Tim Oates Comment 1: Show proposed and existing fire hydrants and fire department connections on the Site Plan. Response: We have provided a preliminary water layout with Fire Hydrants along with appropriate Fire Lane and Utility Easements. V. PARKS AND RECREATION John Elles Comment 1: Tree Removal Pennit will be required prior to start of construction. Tree Retribution will not be required based on plans submitted June 20, 2007. Response: General Comment This concludes our Comments to the Pre-Platting and Pre-Engineering Review. If you have any questions or comments, please call. . ~~ .-~ins KP A consulting 1 BOl GATEWAY BLVD. SUITE 101 . RICHARDSON. TX 750BO . 972.644.2BOO . FAX 972.644.2817 Q:\F"ILES\COMMENTS REPONSES\V'LLAGES @ nl.n CoP"~', ..........,