Loading...
DRC Comments THE.CITY.OP' THE-CITY.OF COPPELL J>(>-~" ... *~ .. r ~ (' q X t\ cS . \ e. CITY OF COPPELL ORe REPORT COPPELL .~f. . r ~ (' q .\' ~ S . \ & Proiect ID Address PO-OJ -0021 Proiect Name Pd-214r2-sf-9 and C, Arbor Manors Proiect Type Re-Zoning PO Application Date 3/21/2007 Case Manager Gary Sieb Proiect Description Zoning change request from C (Commercial), R (Retail) and SF-9 (Single Family-9) to PO-214R2-SF-9 and C (Planned Development-214 Revision - 2 Single-Family-9 and Commercial), with a Concept Site Plan to allow the development of 73 single family homes on approximately 24 acres and commercial uses on approximately 5 acres Agency Building Inspection Reviewed By Greg Jones 1 of 2 Review Date 3/28/2007 Comments 1. No floor plans submitted for review with this case. Electric and Gas Engineering Jeff Curry Ken Griffin 3/29/2007 3/29/2007 No Comments Received 1. Review drainage onto Sandy Lake Rd on north side. Runoff should be intercepted before reaching Sandy Lake Rd. 2. Has the property for cul-de-sac on the west side been acquired? 3. The Wynnpage subdivision to the south shows the 36" RCP stubbed out to pick up water from a portion of this planned development. That 36" RCP is located on Tealwood Dr. Provide a connection to the 36" RCP. 4. The proposed waterline and sanitary sewer on the southwest portion of the planned development do not coincide with existing systems in the Wynnpage subdivision. 5. Proposed 8" waterline should tie into the existing 8" waterline on Denton Tap Rd (southeastern portion of planned development). 6. (from previous DRC comments dated 12/28/06 and 1/4/07) TXU has submitted Work Order #2821838 to install overhead electric lines through this development. The lines themselves are all along Sandy Lake road cutting through this development, then crossing Denton Tap Rd., and continuing through the intersection of Moore/Sandy Lake. The portions of the lines that cross this site will impact Lots 10-17, Block A; and Lot 9, Block B. I would recommend that you contact Richard Brewster with TXU at 214/486-4245 to discuss the TXU lines. These lines need to be relocated. 7. No parking will be allowed on the street in front of Lots 3-6, Block C and Lots 1-5, Block E. THE.CITY-OP' COPPELL ~ s Agency Fire Administration Parks and Recreation Planning Department Reviewed By Tim Oates John Elias Gary Sieb - THE.CITY.OF CITY OF COPPELL ORC REPORT COPPELL .~... r ~ e q ..t t\ cS . \ & Review Date Comments 3/29/2007 1. Fire hydrants shall not be on 'dead-ends' in excess of 150ft. 2. Submit proposed street names as soon as possible. 3. On street parking will be prohibited on streets less than 27ft wide. 4. Provide at least one fire hydrant on each proposed street. 3/29/2007 1. Tree Survey is incomplete. Need to know which trees will be removed due to construction of streets, driveways, houses and utilities. 2. Park Development fees $1285.00 per unit. 3. Tree Removal permit required prior to start of construction. 3/27/2007 1. Please specify in PD conditions that no lot will be narrower than 75 feet, nor shorter than 110 feet. 2. Explain development of cul-de-sac on west property line (how, easement, etc.). 3. Corner lots have two front yards (25 feet). 4. Consider 35% coverage (SF-9) in an attempt to save trees. 5. Need screening wall details--height, material, location, color: clearly show on all exhibits. 6. ALL common areas need to be identified by increasing numbers--1X, 2X, 3X, etc. 7. Show entry pavers on all exhibits. 8. CLEARLY identify all tracts on all exhibits. 9. Identify and define what Article 23 and Section 12 of written PO exhibit means. 10. Tree mitigation comments? 11. Specify maximum height of structures on exhibits and in PO conditions. 12. Landscaping requirements are in Zoning Ordinance, not Subdivision Regs. 13. Specify where what plants go where on Landscape Plan. 14. Indicate wall column spacing (must be between 10-30 feet). 15. Need color board and specifics regarding wall types, colors, heights, etc. 16. Dimension all setbacks on all exhibits. 17. Do lots 5-8 have alley access? If so, clarigy in Sect. 7.0.