Loading...
DRC Comments THE.CiTY-OF' THE.CiTY-OF' COPPELL ~"~"'." . c '* . .. , ... 0 e .t 1\ S : \ ~ q CITY OF COPPELL ORC REPORT .- COPPELL " s Proiect 10 PD-07 -0022 Proiect Name Pd-227 -sf-12, Bellacere Addition, Address 300 W Sandy Lake Rd Proiect Tvpe Re-Zoning PD Application Date 3/21/2007 Case Manaaer Matt Steer Proiect Description Zoning change request from 2F-9 (Two Family Residential) to PD-227-SF-12 (Planned Development 227-Single Family-12) to allow the construction of four single-family homes Agency Building Inspection Reviewed By Greg Jones 1 of 2 Review Date 3/28/2007 Comments 1. Garages that have side access will most likely need more maneuvering room than is provided for on the site plan. Electric and Gas Engineering Fire Administration Parks and Recreation Jeff Curry Ken Griffin Tim Oates John Elias 3/29/2007 3/29/2007 3/29/2007 3/29/2007 2. Maximum pad size shown is confusing on this plan. No Comments Received No comments. 1. Show fire hydrants on zoning exhibiUsite plan. 1. Park Development Fees $1285.00 per unit. 2. Tree Removal Permit Required prior to start of construction. THE-CITY-OF COPPELL " s Agency Planning Department Reviewed By Matt Steer THE.CITY-O'" CITY OF COPPELL ORe REPORT --- - COPPELL ~,~",~,""., . . Nt*' .. , . _' 0 e .t 1\ S -- \ fI q Review Date 3/28/2007 Comments Zoning ExhibiUSite Plan 1. Show a 30' front yard setback. This is a minimum requirement of the Zoning Ordinance measured from the front right-of-way line. In this case, we are asking that it be measured from the fire lane pavement. 2. Garage access shall be from the alley. 3. Depict circular drives on plans adjacent to the fire lane for guest parking. Revise note on all plans. 4. Side yards are required to be 10% of the lot width in SF-12 zoning. Only 10' is shown. Remove notes showing 10' side yard typical. 5, Wall along Sandy Lake should be constructed of brick or stone, not precast concrete. Ensure it connects in with the existing wall to the west Show details of revised wall and label correctly on all plans where shown. Submit a color board showing wall materials. 6. Extend 6' fence along north property line of subdivision and show details on elevation sheet. 7. What type of screening device is planned for the east property line (live evergreen screening recommended)? 8. Show details of subdivision entry sign. 9. Include existing 2F-9 and proposed PD-227-SF-12 zoning in Site Summary Table. 10. Fill in proposed zoning blanks on all sheets. 11. Include architect or builder's information and label elevation sheet as "Conceptual Elevations". 12. Include area to east of fire lane as part of Lot 1 X. 13. Show enhanced concrete at entry. Landscape Plan 1. Four additional overstory trees are required in common area adjacent to Sandy Lake Road, as this is a primary image zone requiring one tree per 40'. Refer to Streetscape Plan of Subdivision Ordinance for more detail. 2. Include evergreen screening along east property line if proposed as screening device. 3. Irrigation Plan is required prior to obtaining a permit 4. Rename second sheet - "Tree Survey". Tree Survey 1. Include size of each tree surveyed in chart if 6" or greater. Screening Wall 1. Include screening wall details compliant with the Zoning Ordinance (no precast concrete, only brick or stone allowed).