Loading...
DRC Comments THE.CiTY.OF ~ ~~r-' COPPELL <5 DRC Agenda and Staff Comments Planning Department 255 Parkway Blvd Coppell, Texas 75019 Phone: 972-304-3678 Fax: 972-304-7092 PROJECT: PD-227R-SF-12, Bellacere Addition and Final Plat PLANNING DEPARTMENT CONTACT: Matt Steer DIRECT DIAL: 972-304-3559 FAX COVER SHEET DATE: December 28,2007 PAGES: (P (including cover) TO: Micha P. Duffy FAX: 817.284.8408 Items Transmitted: 1. Agenda for the January 3, 2008 DRC Meeting 2. DRC Comments Remarks: A. Please revise all plans and plat(s) based on staff recommendations. Should the applicant disagree with staff comments, please provide reasons why staff recommendations should not be followed when you attend the January 3, 2008 Development Review Committee (DRC) meeting. B. Each applicant will bring two new sets of revised plans and plat(s) to the January 3, 2008 DRC meeting. Applicants will be asked to show, explain and defend any revision. A representative of the project is required to attend this meeting. C. The applicant will have until noon, January 8, 2008 to submit 12-24' x 36' sets, FOLDED, and three (3) reduced paper copies (8 1/2 X 11) and JPEG. TIF. PDF OR SIMILAR ELECTRONIC FORMA T of each exhibit. Only two sets of revised preliminary engineering and irrigation plans are required. Reductions and electronic copies are not required of the engineering and irrigation plans. If you have any questions or would like additional information, please contact me at 972-304-3559 or e-mail atmsteer@cLcoppell.tx.us THE.CITY.OP' COPPELL ...~Il * fI.~. ,. ;-~~ THE.CITY.OP' CITY OF COPPELL DRC REPORT COPPELL ...~Il * fI.~. ~ ;-~~ ~ .t J\' 6 . \ f:l q Proiect ID Address PO-07 -0085 Proiect Name PO-227R-SF-12, Bellacere Addition Proiect Type Re-Zoning PO Application Date 12/18/2007 Case Manaaer Matt Steer Proiect Description zoning change request from PD-227-SF-12 (Planned Development-227-Single Family-12) to PD-227R-SF-12 (Planned Development-227 Revised-Single Family-12), to allow for the realignment of the mutual access/fire lane easement, reconfiguration of the common area (x-lot) and change in garage access of Lot 4 from what was previously approved to Agency Building Inspection Reviewed By Greg Jones 1 of 2 Review Date 12/27/2007 Electric Engineering Jeff Curry Michael Garza 12/27/2007 12/26/2007 Fire Administration Tim Oates 12/26/2007 Parks and Recreation 12/27/2007 John Elias Comments Note that no parking would be permitted in the Fire Lane, which includes a portion of the driveway on Lot 4. No Comments Received 1. The drainage will be evaluated further during the engineering plan review. 2. The sanitary sewer should be inside the sanitary sewer easement. 3. Rainfall Intensity coefficient should be 8.88. 4. Consider moving drop inlet to the northeast corner of property opposed to the northwest corner. 1. Show fire hydrant location on the site plan. 2. Fire hydrant shall be located 3'-6' from back of curb. 3. 12-ft gate will be required to connect the fire lane/mutual access easement to the alley north of this project due to the hammerhead not meeting city specifications. 1. Tree Removal Permit required prior to start of construction. 2. Tree Retribution in the amount of $3,900.00 will be required to pull Tree Removal Perm THE.CiTY.O'" COPPELL s Agency Planning Department Reviewed By Matt Steer THE.CiTY.O... CITY OF COPPELL ORe REPORT COPPELL ...~Il * tJj~. ~ ;-~~ e ..t i\,& . \ ~ q Review Date Comments 12/21/2007 Site Plan: 1. Add Lot 1 X to title blocks of all plans. 2. Does proposed fire hydrant location conflict with Tree # 464? 3. Change note on bottom right to indicate correct current and proposed zonings. 4. More clearly define lot boundaries. Show all property lines in bold and easements with dashed lines (shading of fire lane, mutual access and utility easement is okay). 5. Include all turning radii. 6. The Site Plan calls for a 8' wood fence, details show a 6' fence. Landscape PlanlTree Survey: 1. Adjust enlargement of entry to ensure there is no overlapping text. 2. Change note on bottom right to indicate correct current and proposed zonings. 3. Remove file pathway from middle of plans. 4. More clearly label Tree # 422. 5. Relabel "Evergreen Screening" to "Nellie R. Stevens". Screening Wall/ Entry Gate: 1. Ensure plant material in front of the wrought iron sections adequately screens view of lot. 2. Include title of plan sheet - "Screening Wall/ Entry Gate Elevations - Lots 1-4 & Lot 1X, Block A, Balladeer." 3. Submit a sample of stone wall. Lot 4 - Site Plan: 1. Dimension drive from alley, and show pool boundaries. PO Conditions Sheet: 1. Include Lot 1 X in title. 2. Front yard requirements should list the setback exception of Lot 4. 3. List exception to alley access under parking regulations. 4. Ensure Lot area is correct, as lot sizes have been reconfigured since the last proposal. Proposed Zoning Tree Mitigation Summary Sheet: 1. Revise sheet to include all text.