Loading...
DRC Comments 053008 THE.CITY.OF ~'tJt5~ COPPELL 8 DRe Agenda and Staff Comments Planning Department 255 Parkway Blvd Coppell, Texas 75019 Phone: 972-304-3678 Fax: 972-304-7092 PROJECT: PD-233-R CODDell Vision Center PLANNING DEPARTMENT CONTACT: Matt Steer DIRECT DIAL: 972-304-3559 DATE: May 30, 2008 FAX COVER SHEET PAGES: if (including cover) TO: Dr. Laura Pels Mardy Brown, Dowdey Anderson FAX: 972-304-4422 ./ 972-931-9538 / Items Transmitted: 1. Agenda for the June 5, 2008 DRC Meeting 2. DRC Comments Remarks: A. Please revise all plans and plat(s) based on staff recommendations. Should the applicant disagree with staff comments, please provide reasons why staff recommendations should not be followed when you attend the June 5, 2008 Development Review Committee (DRC) meeting. B. Each applicant will bring two new sets of revised plans and plat(s) to the June 5, 2008 DRC meeting. Applicants will be asked to show, explain and defend any revision. A representative of the project is required to attend this meeting. C. The applicant will have until noon, June 10, 2008 to submit 12-24' x 36' sets, FOLDED, and three (3) reduced paper copies (8 1/2 X 11) and JPEG. TIF. PDF OR SIMILAR ELECTRONIC FORMA T of each exhibit. Only two sets of revised preliminary engineering and irrigation plans are required. Reductions and electronic copies are not required of the engineering and irrigation plans. If you have any questions or would like additional information, please contact me at 972-304-3676 or e-mail atmsteerai.-cLcoooell.tx.us --- THE.CiTY.OF THE.CiTY.O..- COPPELL CITY OF COPPELL ORC REPORT COPPELL Proiect 10 Address PD-08-0017 541 Sandy Lake Rd 6 Proiect Name PD-233-R, Coppell Vision Center Proiect Type Application Date Case Manaaer Project Description Re-Zoning PD 5/19/2008 Matt Steer zoning change request from SF-12 (Single Family-12) to PD-233-R (Planned Development-233-Retail) to allow the construction of a 2,600 square-foot medical office on 0.434 acres of property Agency Building Inspection Reviewed By Greg Jones 1 of 2 Review Date 5/30/2008 Electric Engineering Jeff Curry Michael Garza 5/29/2008 5/28/2008 Fire Administration Tim Oates 5/29/2008 Parks and Recreation John Elias 5/27/2008 Planning Department Matt Steer 5/29/2008 Comments No Comments. Further comments will be made during permitting review. No Comments Received 1. The engineering plan should show proposed utilities(water, sewer, drainage). 2. The sidewalk is required in the city ROW along Nash and should extend to the property line. 3. Where the existing driveway is to be removed, sidewalk and curb should be poured back. 4. A preliminary drainage plan should be provided. 1. Show proposed and existing fire hydrants. 2. A fire hydrant will be required on site at the driveway entrance off Nash. 1. Tree Removal Permit will be required prior to start of construction. Site Plan: 1. Ensure all parking is located beyond the 30' setback line on Nash. 2. Revise parking calculations to reflect 496 square feet retail (1 space per 200 sq. ft.) and 2,104 square feet medical office (1 space per 175 sq. ft.) uses. 3. Include separation distance between proposed drive and Sandy Lake. 4. Reverse floor area ratio (should be .137:1). 5. Include subdivision name with lot and block number in all title block. 6. Include phone and fax numbers of owner and applicant on all sheets. 7. Change address of applicant to 757 S. MacArthur. 8, Ensure scale on Site Plan, Landscape Plan and Tree Survey are the same. 9. Change the land use indicated for the properties to the south and southeast. 10. Include a "Planned Development Conditions Table" on the site plan. 11. Note the 18' parking space depth is substandard within the table. 12. 15' perimeter landscaping is required adjacent to rights-of-way and 10' required adjacent to the interior property lines. An islpnd is required at the end of each parking row. If not resolved, this will be required to be noted as a PD condition. 13. Include proposed zoning in the Site Data Table (PD-233-R). 14. Does the "paved area" include the proposed 4' and 5' sidewalks? 15. Include the name of the 7.5' easement on the east property line. THE.CITY.OF COPPELL " s Agency Reviewed By THE.CiTY.OP' CITY OF COPPELL ORC REPORT COPPELL '" ... Review Date Comments 16. Include the location of the proposed mechanical equipment. 17. Include location of proposed monument sign and parking lot lighting. 18. Within the Site Data Table, include the minimum required setback dimensions and proposed setback dimensions. 19. Is a dumpster proposed? Floor Plan is not required with the next submittal unless changes are made to it. Elevation Sheets: 1. Specify all materials and colors. 2. Include windows where stone is shown for exam rooms (blinds or curtains can be used for privacy). 3. Note that "No signage is proposed to be attached to the building" if that is truly the case. 4. A color board is required at DRC showing all materials with a color front elevation sheet. Tree Survey: 1. Ensure Tree Survey is prepared by a registered Arborist, Nurseryman or Landscape Architect. Landscape Plan (Sheet L 1): 1. Include trees to be preserved on Landscape Plan. 2. Include property dimensions and label all utility easements. 3. Include plant list currently shown on the third sheet in place of legend on first sheet. 4. Include a separate sheet with hatching of the 3 categories of landscaping used for calculation purposes. It appears that the area calculations are wrong. Refer to the attached sheet. 5. Include "Landscape Plan" in title block. Landscape Plan (Sheet L2): 1. Reduce the size of the monument sign to 40 sq. ft. This is measured from the top edge of the sign to grade (4' max. height) and farthest edge of column to farthest edge of column on the other side (10' max. width). Redesign sign. 2. Column spacing shown to be 10', but that is for a thinwall column. There are no large columns except at the ends. Recommend adding two of the larger columns along the wall. 3. Ensure the wall specifications are designed and stamped by a registered Texas Professional Engineer. Memorandum ~R Date: May 30, 2008 To: Malt Steer cc: From: Jeff Curry Subject: May DRe PO-229R-LI Minyard Addition (KTR Capital) - zoning change acceptable, please contact Randy Bell at 940.497.7530 to confirm locations of signs will not interfere with Oncor Electric Delivery facilities. PD-209R2-C, TownOaks Centre - zoning change acceptable, please contact Larry Redick at 972.323.8917 to discuss electric service requirements. PD-233-R, Coppell Vision Center - zoning change acceptable, please contact Larry Redick at 972.323.8917 to discuss electric service requirements. CiCi's Addition No.1, Site Plan Amendment - site plan acceptable, please contact Larry Redick at 972.323.8917 to discuss electric service requirements. CiCi's Addition No.1, Lot 1 R, Block 1, Replat - plat acceptable. Fire Station No.1, Lot Block 1, Site Plan Amendment -- site plan acceptable, please contact Larry Redick at 972.323.8917 to discuss electric service requirements. Freeport Parkway R.O.W. Dedicatiou, Preliminary Plat and Freeport Parkway R.O.W. Dedication, Final Plat - Oncor Electnc Delivery will require a minimum 15' public utility casement adjacent to the R.O.W on both sides of Freeport Parkway. Please contacl Jeff Curry at 972.888.1330 to discuss. CONFIDENTIAL