Loading...
DRC Comments THE.CITY.OF COPPELL .~*~. e ~ ~ q J\ s . \ ~ Planning Department 255 Parkway Blvd Coppell, Texas 75019 Phone: 972-304-3678 Fax: 972-304-7092 DRe Agenda and Staff Comments PROJECT: PD-235-0. Denton Creek @ Sandy lake Addition. lot 2. Block A. and lots and 2 . Minor Plat PLANNING DEPARTMENT CONTACT: Gary Sieb DIRECT DIAL: 972-304-3678 DATE: August 29, 2008 FAX COVER SHEET PAGES: Co (including cov~ FAX: 972-516-8901 TO: Robert Schneeberg, Gonzalez & Schneeberg. Items Transmitted: 1. Agenda for the September 4, 2008 DRC Meeting 2. ORC Comments Remarks: A. Please revise all plans and plat(s) based on staff recommendations. Should the applicant disagree with staff comments, please provide reasons why staff recommendations should not be followed when you attend the September 4, 2008 Development Review Committee (ORC) meeting. B. Each applicant will bring two new sets of revised plans and plat(s) to the September 4, 2008 DRC meeting. Applicants will be asked to show, explain and defend any revision. A representative of the project is required to attend this meeting. C. The applicant will have until noon, September 9, 2008 to submit 12-24' x 36' sets, FOLDED, and three (3) reduced paper copies (8 1/2 X 11) and JPEG, TlF, PDF OR SIMILAR ELECTRONIC FORMA T of each exhibit. Only two sets of revised preliminary engi'1eering and irrigation plans are required. Reductions and electronic copies are not required of the engineering and irrigation plans. If you have any questions or would like additional information, please contact me at 972-304-3678 or e-mail atQsieb@cLcoooell.tx.us THE.CITY.OF COPPELL ~~~~ * ~... rr:-~~:-\) X 1\ S \ & THE C I T Y o F CITY OF COPPELL ORC REPORT -...--- COPPELL ~~~~ * t!-~. . ... r e-~~o -t t't {) \ & Proiect 10 MP-08-0034 Address 1320 E Sandy Lake Rd Proiect Name Denton Creek @ Sandy Lake Addition, Lots 1 and Proiect Type Minor Plat Application Date 8/19/2008 Case Manaqer Gary Sieb Proiect Description to allow the construction of a single family home on Lot 1 and a two-story office building on Lot 2 Agency Building Inspection Electric of Review Date Reviewed By Greg Jones Jeff Curry 8/27/2008 8/28/2008 Engineering D. Baskins 8/28/2008 Fire Administration Tim Oates 8/25/2008 Parks and Recreation Planning Department John Elias Gary Sieb 8/25/2008 8/26/2008 Comments 1. No comments on plat. Please contact Larry Redick at 972-323-8917 to discuss electric service requirements. 1. The 17' by 15' utility easement should be increased to a 20' by 20' utility easement. 2. Show the fire lane/ access easement. Is there mutual access agreement? 3. The utility plan and the drainage plan will have comments during the engineering plan review. 4. Label the Base flood elevation on the flood plain. 5. The fire lane should have an 8" meter and detector check valve. 1. Address for Lot 1, Block A (residence) will be 1180 E. Sandy Lake Rd. 2. Address for Lot 2, Block A (commercial bldg) will be 1188 E. Sandy Lake Rd. No comment. 1. Remove tree symbols from plat document. 2. Eliminate topo lines from this plat. 3. Utility company signature blocks need to be included on plat. 4. Is it possible to reduce the scale of the plat and get all information on one sheet? 5, Building setback line between office parcel and residential zoning to the east needs to be 25 feet. 6, See Fire Administration comment requiring fire lanes be shown on plat.