Loading...
A1 Floor Plan .~ (;j o .:::t:. '(j) > OJ E a. L() <? ~ <Xl o o N o u (]) o o w 1= o .....J a... N ~ X o ("') (]) +J f= ~ ("') o ~ ~ ,..... ("') I x ill ~ 4 ~ ("') o ~ ~ ,..... ("') I x iJj u.. W lY X OJ 3 ~ < ~ ("') o ~ ~ ,..... ("') en ~ w W I C/) :::J ~ :J ~ () w !:: I () lY ~ o o lY a... X ~ ~ a. a. o () (0 5 o (0 <Xl ~ ~ u.. (i) "'5 o a. C/) en ~ () W , o lY ~ cr b u.. z W .....J u.. F E o c NOTE: ACCESSIBiliTY NOTES: NOTES BY SYMBOL "0" SEE SHEET AS FOR WALL TYPE LEGEND (TYPICAL) 1. ACCESS TO THESE FACILITIES SHALL BE PROVIDED AT PRIMARY ENTRANCES 2. THE SLOPE OF PUBLIC WALKS SHALL NOT EXCEED MAX - CROSS SLOPE 2% 3. WALKING SURFACE SLOPING GREATER THAN 2% SHALL BE SLIP RESISTANT. 4. PROVIDE A 60" X 60" MIN. LANDING W/18" CLR ON STRIKE SIDE OF DOOR WITH 44" MIN. WIDTH IN DIRECTION OF TRAVEL 5. WALKS SHALL EXTEND 24" TO THE SIDE OF THE STRIKE EDGE OF A DOOR OR GATE THAT SWINGS TOWARD THE WALK. 6. THE SLOPE OF RAMPS SHALL NOT EXCEED 1'-0" IN 15'-0" U.N.O. 7. RAMPS SHALL HAVE A NON-SLIP SURFACE 8. RAMPS SHALL BE 48" WIDE MIN. 9. EVERY REQUIRED EXIT DOORWAY SHALL BE SIZED FOR A DOOR NOT LESS THAN 3 FT. WIDE BY NOT LESS THAN 6'-8" HIGH CAPABLE OF OPENING 90 DEGREES AND MOUNTED SO THAT THE CLEAR WIDTH OF THE EXIT WAY IS 32" MIN. 10. THRESHOLD TO BE A MAX. 1/4" ABOVE ADJACENT FINISH FLOOR. 11. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 LBS. 12. THE BOTTOM 12" OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE. 13. 1008.1.8.1, IBC. HARDWARE. DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS REQUIRED TO BE ACCESSIBLE BY CHAPTER 11 SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE. 14. ALL DOORWAYS LEADING TO SANITARY FACILITIES SHALL HAVE 32" CLEAR UNOBSTRUCTED OPENINGS. 15. LOCATE WC. IN A 60" X 60" MIN. AREA, 18" FROM WALL TO CENTER LINE OF WC. 16. PROVIDE 48" X 48" SPACE AT PUSH SIDE OF DOOR AND 54" X 60" DEEP SPACE AT PULL SIDE OF DOOR INTO TOILET ROOM AND WC. STALL 17. PROVIDE 1-1/2" O.C. GRAB BARS AT 33" A.F.F. AT REAR AND SIDE OF W.C. GRAB BAR AT SIDE TO BE 42" LONG AND EXTEND 54" FROM BACK WALL OF TOILET. GRAB BAR TO BE 36" LONG AT BACK WI 1-1/2" CLR. FROM WALL BAR FASTENERS AND MOUNTING SUPPORTS TO WITHSTAND A MIN. 250 LBS. PER FT. IN BENDING, SHEAR STRESS AND SHEAR FORCE. 18. WATER CLOSETS SHALL HAVE A SEAT HEIGHT OF 17" TO 19" A.F.F. FLUSH VALVES TO HAVE MAX. 5 LBS. OPERATING FORCE. 19. URINAL TO HAVE AN ELONGATED RIM AT 17" A.F.F. MAX. AND A CLEAR SPACE OF 32"X48" IN FRONT. FLUSH VALVES TO BE MOUNTED 44" A.F.F. AND HAVE MAX. 5 LBS. OPERATING FORCE. 20. PROVIDE 30"X 48" CLEAR SPACE IN FRONT OF LAVATORY AND 29" CLEAR FROM FLOOR TO BOTTOM OF APRON FOR KNEE SPACE. 21. PROVIDE A CLEARANCE 27" HIGH x 8" DEEP BEHIND FRONT OF LAVATORY AND A TOE CLEARANCE OF 9" FROM THE FLOOR AND 17" DEEP FROM THE FRONT OF THE LAVATORY. 22. INSULATE HOT WATER AND DRAIN PIPES AT HAND SINKS. 23. FAUCET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE GRASPING, PINCHING, OR TWISTING, FAUCET TO HAVE MAX. 5 LBS OPERATING FORCE, PROVIDE SELF-METERING FAUCET WHERE REQUIRED BY LOCAL GOVERNMENTAL REGULATIONS - SEE PLUMBING 24. LOCATE TOWEL, SANITARY NAPKIN, AND WASTE RECEPTACLES, WITH ALL OPERABLE PARTS WITHIN 40" OF FLOOR. 25. LOCATE TISSUE DISPENSERS ON THE WALL WITHIN 9" FROM CENTER LINE OF DISPENSER TO THE FRONT EDGE OF THE TOILET SEAT AND 19" A.F.F. SEE 5/FN2 & 11/FN2 26. SELF CLOSING DOORS TO REMAIN OPEN FOR MIN. OF 10 SECONDS. 27. PUBLIC TELEPHONES (INTERIOR AND EXTERIOR) ARE TO BE PROVIDED WITH TELEPHONE BOOK LOCATION 15" A.F.F. MIN, TO 48" A.F.F. MAX OF FORWARD REACH OR 9" A.F.F. MIN. 54" A.F.F. MAX. FOR SIDE REACH, CORD LENGTH ON RECEIVER TO BE 29" MIN., VOLUME CONTROLS PROVIDING 12 dba MIN. TO 16 dba ABOVE NORMAL ACCESSIBLE TELEPHONES ARE TO BE PROVIDED MIN. (1) PER EACH BANK OF PHONES OR AS REQUIRED BY A.D.A. STANDARDS. 28. WATER CLOSET FLUSH CONTROL TO BE LOCATED ON THE WIDE SIDE OF STALL PER ADAAG 4.16.5 29. PROVIDE INTERNATIONAL SYMBOL OF ACCESSIBILITY AT REST ROOMS. (RE: 7,8/AD5) 1. RAISED 4" CONCRETE CURB SLAB FOR CASES. RE: 03/AD4 AND REFRIGERATION DRAWINGS 2. EXISTING STEEL COLUMN. PROVIDE 48" HIGH STAINLESS STEEL COLUMN WRAPS - NO WRAPS @ SIM. 3. CONCRETE CURB BASE AT PERIMETER WALL OF COOLER I FREEZER BOX - RE: 01/AD2 4. CONCRETE CURB BASE FOR COOLER I FREEZER WALL - RE: 02/AD2, 04/AD2 & 05/AD2. 5. CONCRETE CURB AT PRODUCE DOOR - RE: 03/AD2. 6. PIPE BOLLARD - RE: 04/AD1 7. FIRE SPRINKLER RISER 8. REFRIGERATION EQUIPMENT ON ROOF - RE: REFRIGERATION DRAWINGS 9. LINE OF ACOUSTIC TILE 10. PLUMBING VENT OR REFRIGERATION LINE CHASE 11. PRE-FAB COOLER I FREEZER WALL 12. STOCK ROOM BOLLARDS - RE: 19/AD1 & 08/AD4 13. ACCESSIBLE ELECTRIC BI-LEVEL WATER COOLER - RE: 17/AD1 14. AUTOMATIC DOOR WITH SENSORS - RE: 17/AD2 15. UNDER FLOOR WALKER DUCT ELEC. CHASE - RE: 08/AD2 AND ELECTRICAL DRAWINGS 16. EXISTING FACADE POP-OUT 17. LINE OF SOFFIT ABOVE - RE: 13/AD3 18. SLOPE CONCRETE SLAB TO DRAIN NOTE: PRODUCE COOLER SLOPE TO TRENCH DRAIN 19. S.S. CORNER GUARD CAP TO +48" A.F.F. - FROM TOP OF BASE TO CEILING AT SIM. 20. PROVIDE 3/4" PL YWD. WAINSCOT ON GYP. BD. WALL - RE: 07/AD2 21. STEEL BASE ANGLE - RE: 04/AD2 22. IBC 1008.1.8.3 "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED." PROVIDE SIGN AT BREAKAWAY PANELS "IN EMERGENCY PUSH TO OPEN." 23. GALVANIZED STEEL CORNER GUARD 48" HIGH. SIM USE CAP 24. SOFFIT WALL OVER COOLER BOX - RE: 14/AD3 25. PROVIDE COPING AT CONCRETE CURB FOR FLOOR SINK 26. ROOF ACCESS LADDER - RE: 01/AD3 AND 02lAD3 27. TRENCH DRAIN - EXTEND 8" BEYOND DOOR JAMBS - RE: PLUMBING DRAWINGS 28. FIRE EXTINGUISHER SEE SHEET F1 FOR TYPE. FINAL LOCATION TO BE COORDINATED WITH LOCAL FIRE AUTHORITY 29. HAND SINK - RE: PLUMBING DRAWINGS 30. S.S. FULL HT. AND WIDTH TO UNDERSIDE OF HOOD - EXTEND 18" BEYOND FACE OF HOOD AT SIDES 31. REFRIGERATION EQUIPMENT ON TOP OF WALK IN COOLERS 32. 6" THICK CONCRETE SLAB WITH W.W.F. REINFORCING RE: STRUCTURAL DRAWINGS 8/S3 33. NOT USED 34. WALL MOUNTED FLY FAN - RE: MECHANICAL DRAWINGS AND 18/AD1 35. STRIP CURTAINS - N.I.C. 36. OPENING IN COOLER WALL FOR WINDOWS BY COOLER BOX MFR. ~ 1 2 ~ 4 3 ~I LoI NI ~I 3. j /" ( 2 'r. ~..j 1 '., 4 .G- ~ f1 .0 iO 1 J . .... t ~ ;0 ~ ===6===0 1/1 OWN 3 -.- o. 0~R~:~~~_~T~4RAL MEZZANINE FLOOR PLAN l~-.. 'l. I ~ Lo 1 n +___ u._____._n__ 31'-6" 1 ,I- 31'-6" 31'-6" 31'-6" I +-. .- ".. .". 26'-2" t--- 37'-7" 58'-7" ------- - -- ~---- - 17'-10" 44'-2" r t . ..-- )t-- A' , qt.. q) DEMISING WALL B'fOTHEA _ r ~ ICE MACHINE AREA 11361 .~ 0, DELI ~ PR~D [1111 b Cry ("') DEMISING WALL BY OTHER CD .... ..'1. ~ t-- ~ I" ..JI @j, ._-~ 32'-9" ~ .>j... ~, ~,~ Lo Cry':> L() '\,.. \ . ~'. ~- -=== ~- -7=~"= ~ 19 ~s~E~~ CD]] r;.~g~~~rE I ~, i t \ \ ADS OJ>;u.: LoI~ NI> 1 1$ I I OJ> t-- ~ )f " 24'-11" 51' -0" ~rB i I 9: ~i ,----, ~ ~r~r ~ RODUCE / BULK PREP AREAS 11241 I I I i --1 . 1 ~' Cry ("'), , "" F4 S1 F1 91 Lo __._u ----- -.--- . -.... .>i. E 20 .~Jk~1JI i' .1(EI1~'~J ilSuJ I L I - - ~_..... --=-, -""'--~ --- 31'-10" i~3 ! ',' 1.2'-4" >f- - ' b -' I 0>, ~I N ~, 18'-6" MAl N SALES AREA 11001 '-0. ~ ;. LoI ~I ,.....1 i ! i 1 I I ~ "" , STOCK AREA #1 01TI 9 b N: ~ ~2'-2" -t l- . '-0" 3'-0", 6.. ~,r/ -t" \ or, ...- ~ Co 3~1 2 I FIN. FLOOR ELEV. 000'-0" 1 "" , I 91 i:o: <;> <;> 0" Lo ("')' 1 RECEIVING [I!ID I ~ ~@)r rs1 -- 40J '~ I~ .1' , :1 I / " ~ ~:" 60 r / 10'-7 1/2" ~. 0, S1 F1 STOCK AREA #2 11221 ., ~I I I 'I. 19'-8" 19'-2" ~ 10'-2" -t ---- .--. 5'-4" ",. V.I.F. ~ EJ 10'-6" vJJ=. ~ ~ ~ ~: Lo ("') /\ I ~/'-',} L@-l ~ I / i ._-j ~ Lo 20 AD2 20 AD2 b F1 N N, 23'-2" 23'-1" 8'-1" ,1<:. '\,. , ?. '-8.." 3'-4" ,.c /,t 7'-6" 208'-6'" ~ ~ 225'-4" V.I.F. ,It I 21 '_8" VlF. I {' ~ @ ~ / H ' \ J ", / /~ ( G\ ~) o /-------" ( E ) \...~../ /~ (D \ \'--~) o CD~AR:~/~~.~.C~6URAL FLOOR PLAN D c <{ W F E B A 37. LOADING RAMP - DOCK LEVELER 38. DOOR COOLER I FREEZER 39. IMPACT DOORS - RE: 12/AD2 AND 13/AD2 40. S.S. CLOSURE BY G.C. 41. SERVICE ENTRANCE SECTION - RE: ELECTRICAL DRAWINGS AND 12/AD1 IF REQ'D BY UTILITY COMPANY 42. 1 x 10 KILN DRIED ROUGH SAWN WOOD PANELING OVER GYP. BD. FULL HT. - RE:FN2 43. TELEPHONE MOUNTING BOARD - RE: ELECTRICAL DRAWINGS 44. 3-COMPARTMENT SINK - RE: PLUMBING DRAWINGS 45. MILLWORK PROVIDED BY SPROUTS 46. RECESSED KNOX BOX - LOCATE PER LOCAL FIRE DEPARTMENT REQUIREMENTS 47. EXISTING PLANTER LANDSCAPING 48. NOT USED 49. ADJACENT TENANT I BLDG. (NIC) 50. NOT USED 51. GAS METER - RE: PLUMBING DRAWINGS FOR SIZE AND UTILITY COMPANY STANDARDS FOR BOLLARDS 52. EXISTING TRANSFORMER TO BE RELOCATED - RE: ELECTRICAL DRAWINGS 53. COORDINATE U/G UTILITIES IN THIS LOCATION 54. JANITORS SINK WI 48" HIGH S.S. WAINSCOT EACH WALL - RE: 09/AD1 AND 08/AD1 SIM. 55. CASHIERS DROP SLOT @ 40" A.F.F. - COORDINATE WI OWNERS SUPPLIED EQUIPMENT 56. INTERIOR DECORATION AWNING ABOVE - RE: 20/AD2 57. 8" C.I.P. CURB WITH MITERED CORNERS 58. EXISTING ROOF DRAIN 59. COUNTER MILLWORK BY G.C., MAX. HT. @ COUNTER SURFACE 36" A.F.F. 60. RECESSED HOSE BIBB W/COVER RE: PLUMBING DRAWINGS 61. 5" MIN. THICK STANDARD GREY CONCRETE COVER WI VCT - SEE SHEET FN1 62. LINE OF AIR HANDLER 63. WATER HEATER - RE: PLUMBING DRAWINGS 64. TACTILE EXIT SIGN PER TITLE 24 AND 2006 IBC AT EXIT DOOR 65. EXISTING WARNING STRIP 66. BARN FEATURE ABOVE - RE: FN2 AND A6 67. NOT USED 68. MILLWORK BY G.C. - 30" HIGH COUNTERTOP 69. MILLWORK BY G.C.. - 36" HIGH COUNTERTOP @ BREAK ROOM & TILL CABINET IN CASHIERS OFFICE 70. PREP SINK - RE: PLUMBING DRAWINGS 71. TRUCK DOCK BUMPERS 72. RO. SYSTEM 73. GREASE INTERCEPTOR - RE: PLUMBING DRAWINGS 74. EXISTING TO REMAIN AND COVER TO MATCH EXTERIOR FINISH 75. COFFEE SELF SERVICE FIXTURE W/GRINDERS - FOR REFERENCE ONLY 76. HOSE BIBB - RE: PLUMBING DRAWINGS 77. WATER METER - EXISTING ON REAR SIDE OF ADJACENT TENANT 78. 30 YARD TRASH COMPACTOR 79. TRASH COMPACTOR DOOR 80. HOLLOW METAL DOOR - RE: DOOR SCHEDULE 81. S.C. WOOD DOOR - PAINT GRADE 82. EXISTING CONCRETE SIDEWALK 83. FLY FAN @ DOCK DOORS RE: 18/AD1 84. DOOR BELL -INSTALL MUSHROOM BOTTOM @ 5'-0" A.F.F. PAINT TO MATCH COLOR OF MULLION 85. BALER 86. NOT USED 87. NOT USED 88. RECESS SLAB 1/2" FOR WALK OFF MATS - SEE SHEET FN1 FOR ADDITIONAL INFORMATION 89. HAND RAILING 2' BEYOND BEGINING OF RAMP 90. NOT USED 91. EXISTING ELECTRICAL PANELS FLAME SPREAD RATINGS MATERIAL FLAME SPREAD INDEX VINYL WALL COVERING 15 FIBERGLASS REINF. POLYESTER PANEL (SMOKE DEVELOPED RATING -0-450) 155 CEILING TILE (LAY-IN) 25 BATT INSUL EXPOSED (SMOKE DEVELOPED RATING-50) 25 COOLER/FREEZER PREFAB BOX INSULATION (SMOKE DEVELOPED RATING-300) 25 ROUGH SAWN 1X PLANKS 70-100 FINISH NOTES: 1. ALL BACKROOM WALLS TO BE TAPED DRYWALL 2. ALL GYP. BOARD WALLS IN PREP ROOMS TO HAVE TEXTURED FRP FULL HEIGHT WITHS.S. BASE 3. ALL GYP. BOARD TO BE PAINTED - SHALL BE LEVEL FIVE FINISH 33'-6" 32'-6" ..tf :1,: ~ I;~ '-/ I :1 .1 I o l' ~ ' ,t' _3~'--?~___ 12'-4 " . -7(-- .~ 1" <9 ~ -- - - ~ --- -- r --- -- -- " -;.... ~ - ~---~ I ~ ' - -f- IN ADJACENT TENANT SPACE 21' -3" 21'-3" Ni ;::1 ~i 1 N' ~I i I . I ~I I ~I . . t ~I . NI ~ I ~I I f~ i = I I ~I I ~' ~ II II '? Cry 'Ai Ii/-@) ~. ,i Ii 1 '- " 18'-3" i I I I ; BAKEJ SALES I [D1J 9 -.07 -j 9 N ____________ .. _2_4'::_ffi__. ____ IIII <0 it) IIII ~ ~IIII ~ ~ III ~ ~ IIII Cry IIII ~ 1111 Co ~ ~ IIII _ wi::: ~1~ ("') IIII t -: "f ~II~~:" - - - ~1I.{::r ~-- II1I .~-l- .~. (01 IIII h+.__ IIII I UU 9! ~ Cry ~ Lo N ~ <0 ("') . 1 ~I ("')1 ~I N' ~ ~ 3 ~I ~: I I ~ =1' 'l' 01 0t i 9 <:;> ~ b N ~ 1- I 1 I ~. ! I I · , t I N -'\,-. w 1 I ~I "'-1 ~i i J 'I. f"'t- I /- -', ,( 2 ') i\,----/ b b , 0, N Co N VITAMIN 1130 I , 0, F1 S3 r'-~ ~ ~~ """1 ~ ~(1) ....../ --- - - - --+ -- - -.- - -----------~-- 1 I / v'~~~,~\ : c "~ I) ~ i 008 )) \ I / .~ 1/ (-<l ~ ftt/~Q. Dff'~~~"<<; -. --f o o B A COPYRIGHT e2005 CARTER & BURGESS Carter-Burgess Carter & Burgess, Inc. 101 N First Ave, Suite 3100 Phoenix, Arizona 85003 ISSUES/REVISIONS NO. DATE DESCRIPTION o ~V1 ~~ ~t:cn ~~C; ~~~~ O~~~ ~ ..J 1-., ~~~ :J ~~~~ <enD. ~I-O tn!U ..... ~~ I " " I I '\\ '" ...bi '>;. "':1" ~l. r 'i !,~(. '-.1 '~. ! ii! ,A- I )'. ))lL~JJ J i . I , ,J : F NE6S::GT I I [If ~ PROJECTLOCATION W. SANDY~~ 'ESANDY lAKE RD. KEY PLAN \ \ (3 PLAN BAM/SS PROJECT NUMBER: DATE: F1W18606 11/10108 ARCHITECTURAL FLOOR PLAN CHEn ~--' A1 C C ~-;- ." _ b2j.U61._. ~