PROJECT: PD-239-R, Denton Creek Nursinq
(Sandv Lake Nursinq) and Minor Plat
PLANNING DEPARTMENT CONTACT: Marcie Diamond
DIRECT DIAL: 972-304-3676
FAX COVE ~ET U~ ~
DATE: January 29, 2009 PAGES: ~ (including cover)
TO: ~ ry Parker FAX: 903-592-9292 j~~~`~~
erry Monk 972-272-8761 ~
Items Transmitted:
1. Agenda for the February 5, 2009 DRC Meeting
2. DRC Comments
Remarks:
A. Please revise all plans and plat(s) based on staff recommendations. Should
the applicant disagree with staff comments, please provide reasons why staff
recommendations should not be followed when you attend the February 5,
2009 Development Review Committee (DRC) meeting.
B. Each applicant will bring two new sets of revised plans and plat(s) to the
February 5, 2009 DRC meeting. Applicants will be asked to show, explain
and defend any revision. A representative of the project is required to attend
this meeting.
C. The applicant will have until noon, February 10, 2009 to submit 12-24' x 36'
sets, FOLDED, and three (3) reduced paper copies (8 1/2 X 11) and JPEG,
TIF. PDF OR S/M/LAR ELECTRONIC FORMAT of each exhibit. Only two
sets of revised preliminary engineering and irrigation plans are required.
Reductions and electronic copies are not required of the engineering and
irrigation plans.
If you have any questions or would like additional information, please contact me at 972-304-3676 or
e-mail at mdiamond(a~ci.coqqell.tx.us
T H e• c i r r• o R r H`• c i r r• o F
COPPELL CITY OF COPPELL COPPELL
~ ~ DRC REPORT -~r ~ ~ ~
r - l o r ~ a o
F~, A s t B 9 E' A b 1 g 9
Proiect ID PD-09-0004 Proiect Name PD-239-R, Denton Creek Nursing
Address N of Sandy Lake E of R
Proiect Tvpe Re-Zoning PD
Aqplication Date 1/21/2009
Case Manasaer Marcie Diamond
Proiect Description zoning change request from SF-12 (Single Family-12), R(Retail ) and 0(Office) to PD-239-R (Planned
Development-239-Retail) to attach a detail site plan to allow a 52,317-square-foot (123 bed) Nursing and Rehabilitation Facility
on 6.74 of land
1 of 2
Agency Reviewed By Review Date Comments
Building Inspection Greg Jones 1/29/2009 1. Architect needs to provide floor plan for review along
with building code analysis on proposed building. Based
on Institutional occupancy proposed and construction
type, east setback may not be adequate.
2. Site plan appears OK as to buiiding location (see note
above).
Electric Jeff Curry 1/29/2009 No comments received.
Engineering Michael Garca 1/28/2009 1. The fire line should not be in an easement, this is a
private line. The vaults should be in a 20X20' utility
easement.
2. Check the valve spacing for the water line.
3. Water tie-in shall be done by dry bore of Sandy Lake
Rd.
4. The city will be installing a traffic signal at this location.
The 4th leg may be the responsibility of the property
owner.
5. The drainage plan is incomplete. It will be further
evaluated during the engineering plan review.
6. The finish floor should be at least 2 ft. above the Base
Flood Elevation.
7. Extend the sanitary sewer to the property line.
8. Remove the double check valve at the building.
Fire Administration Tim Oates 1/30/2009 1. Address range for this property is 1350 to 1390 (even)
E. Sandy Lake.
2. Relocate fire hydrant and fire department connection
(FDC) at the SW corner of building to the landscape
island west approx. 40 ft.
3. Based on construction type, an additional fire hydrant
is required on the SE side of the building.
4. The curve in the fire lane on the east side of property
may need to be reconfigured.
Parks and Recreation John Elias 1/26/2009 No comment.
T M E • C I T Y • O F ~ T M 6 • C 1 T Y • O F
COPPELL CITY OF COPPELL COPPELL
~ - ~ ~ ~ . ~ ~ DRC REPORT ~ * o ~
~ ~
F~, ~ g q X A s t g 9
A g . ~
Agency Reviewed By Review Date Comments
Planning Department Marcie Diamond 1/28/2009 1. Re-Iabei all sheets Denton Creek Nursing Home to
match the name of the subdivision and use consistent title
blocks/owner/engineer/landscape architecUsurveyor etc.
on all sheets.
2. Revise name and locations of all utility easements to be
consistent on all site plan sheets and plat.
Site Plan:
1. Add existing zoning district on adjacent properties.
2. Explain the following notes:
a. "THIS AREA TO HAVE ADDITIONAL
LANDSCAPING"
b. "PROVIDE ACCESS ACROSS EX. WATER
EASEMENT"
' 3. Does the existing water line easement allow paving and
~ planting of trees?
4. Correct viciniry map - Sandy Lake not Sandy Lakes,
and add Riverview Drive
5. On the Site Data Table, correct side and rear setbacks
to minimum of 30'.
6. Remove copywrite note, as these are considered
official public documents.
Landscape Plan:
1. Verify and correct tree counts - i.e. Plant List indicates
6 Burr Oaks and there are 8 on the plan, also at the
northwest corner of the site, the label indicates two Cedar
Elms where only one is shown.
2. Required trees are required to be 3" caliper at the time
of planting. It appears that only approximately 77%
(depending on corrections to the tree as noted above)
meet this criterion.
3. Review and revise the General Landscape and Tree
Protection Notes to those applicable in the city of Coppell
and this project. Also, increase the legibility.
4. Use different tree symbols for individual tree types.
5. Landscape Data Table:
a. Perimeter Landscaping: 32 trees required is
correct..."(# reduced at west side of property)" is
incorrect... Utilizing the existing trees that are to be
preserved along the north property line would be
appropriate as stated in note B). Reference Tree Survey
Sheet.
b. A tree is required at the end of every row of parking.
Several are missing.
6. Include screening for mechanical equipment.
Tree Survey:
1. Remove all platting information and notes.
2. Add a Tabie which includes numbered trees, by types
and Caliper inches being preserved.
Elevations:
1. Re-label north, south, easUwest.
2. Provide calculations to assure compliance with the
80% masonry on each e~evation.
3. Elevations need to be to a definable scale.