Loading...
Structural Evaluation 3091 ~9-PAT 3/ 19/2009 AMERICAN TOWER" C O R P O R A T 1 O N Level 1 Structural Evaluation 1 ATC Site Number & Name 309159, Gra evine Lake Engineering ID: 43099011 Catrier Site Number & Name TX-DAL6168, Gra evine Lake Site Address Coppell Road Cop ll, Texas 75419, Dallas County Tower Descri tion 120 ft Andrew Mono ole Standards & Codes Basic Wind Speed: 70 mph (Fastest Mile) Radial Ice: 61 mph (Fastest Mile) w/ %Z" radial ice Code: ANSIfI'IA/EIA-222-F / 2003 IBC Criteria per Section 1609. l. l, Exception and Section 3108.4 Table 1: Eaostin Antenna Confi ration EL. (Ft) QTY A,NI~NNAS MOUNT COAX (in) CARRIER , 9 Antel RWB-80015/90 ~9~ ~~g 3 CSS CSS XS4-65-R (6)15/8 3 CSS CSS-DTMA-BRS 120.0 Low Profile Platform Sprint Nexte( 1 Dragonwave A-ANT-18G-2-C _ 1 Dragonwave A-ANT-2;G-1-C _ 3 Dragonwave Horizon Compact (3~ ~/g 6 EMS RR65-19-02DP . ~9~ 7~g 110.0 3 RFS APXV 18-206~ 17S-C-A20 Low Profile Platform (12) 7/8 T-Mobile 6 RFS ATMAP 1412D-1 A20 _ 1 RFS MA0528-28AN (1) 7/8 99.5 T-Arm Metro PCS 6 Andrew UMWD-03319A-XDM (12) 1 5/8 94.0 3 Allgon 7332 Flush (3) 7/g _ i Andrew VHL,P2-180 (2) 0.405 90.0 Flush FiberTower 1 Andrew VHLP2.5-180 (2) 0.405 Table 2: Pro osed Antenna Confi ration EL. (Ft) QTY ANI'ENNAS MOUNT COAX CARRIIIt 114.5 2 I?ragonwave A-ANT-18G-2-C Side Arm (2) 1/2 Clearwire Proposed coaa to be installed outside monopol~ - The subject tower and founda.tion are adequate ~"~r~. ` t ' •w~~a• J iJ~e.4w:;....... to support the above stated loads in conformance ~ ' . with specified requirements. 3 ; _ ~ ; lE. ?s ~fweea~s~.+ea~aaye~~>x..-.,. . - {-.:t• 6 t'.. ~rt n r , ~ . ::~i s y'o~4~'vi'.~ . . . L . 2 . • S., ) . i.~ "~..1 ~ ~ ' ef { . C' ( '~s~ trt' 1~*~ . T'' ~ v3~~a~c~f~1.. ~~~...a _ i f - _ . ~v. ~1~;~ ~y r~ !,r! 1; ! ~s ~ "y` ~ ~ n d ~,:.1_'~ = ~ w~°~_~ ~'=~'3 Z° I hereby certify that this engineering document was prepared by me or under my direct personal supervision and that [ am a duly licensed Professional Engineer under the la~vs of the State of Texas. ' The existing and proposed loads of Tab/e 1 and Table 2 are compared to the tower's current design capacity or previous analysis. ZThe design wind criteria are compared to the current code requirements. 3 The tower should be re~valuated as future loads are added or if actual loads are found different from those mentioned in the above tables. 400 Regency Forest Drive • Cary, NC 21518 • 919.468.0112 Office • 919.466.5414 Fax • www.americanto~ver.com ~