Tree PlanCANYON DRIVE
EXISTING TREE PLAN
1"= 30' -0" 0 15 30 60
EXISTING TREE NOTES
Exist "g :tees to rernair snail be protected dirirg constructon from
tree structure damage and co'npacton of SOII under aid around
or,p1rre (caiopyi of 'ree
2
If a'ry root structure s damaged during adjacent
excavation construction notify the Architect immediate y It is
recommended that a censed Arbonst be secured for the treatmert
of any poss�bie tree wourds
3
No disturbarce of the soy' greater'han 4" shall be ocated closer to
the tree trunk than 1 2 the of stance Of the dr,.p '.one to tie tree iru'-k
A m r,mum of 751/o of the drip iine and root zone snail be preserved
at natural grade
Ary fire grading done with,n the critca root zones of the protected
trees rnust be done with light macr,,rery such as a bobcat or light
tractor No earth moving equipment with tracks is allowed within the
cntica root zone of the trees
5
Material Storage No materials intended for use n cois'ruction or
waste materials accumulated due to excavation or demo non shall
be placed within the limas of the drip re of any tree
6
Equipment Cleaning Liquid Disposal No equipment may be
cleaned. toxic solutions. or other liquid chemicais sha;i be deposited
withii the I mats of the dripline of a tree Triis would rciude but not
be IT Wed to pl oil solvents asphalt, concrete. mortar primers.
etc
Tree Attachments No signs wires or other attachments other than
those of a protective nature shall be attached to any tree
VehicL.lar T,affic No vehicular and corstructior equipment traffic or
parking is al owed wither the I mats of the dripline of trees
9
Boring of Jtil,Les May be permuted under protected trees in certain
circumstances The miivnum length of the bore shal! be the width of
the tree's canopy and shall be a m,r mum depth of'orty eight (48")
,,ones
'0 Trenchi,ig Any irrigation trenching which must be dove wrthrn the
critical root zone of a tree shall be dug by hand aid enter the area n
a radia manner
free f agging All trees to be removed from the site shall be flagged
by the Contractor with bright red vinyl tape (3" widthr wrapped
around the main trunk at a he grit of four (4') feet above grade.
Flagging sl be approved by Landscape Architect prior to any tree
emova� Contractor shall contact Landscape Architect with 72 hour
nonce 'o schedu'e on site meeting
'2 Protective Fencing All trees to remain, as noted or drawif shall
have protect ve fencng located at the tree's dnplr,e- 1 he protective
fencing may be comprised of snow fencing, orange v nyl construction
fencing- chain link fence or other similar fencing with a four (4') foot
approximate height The protective fencing will be 'ocated as
rid cated o" the Tree Protection Detail(sl
3 Bark Protecton In s tuations where a tree remains n tyre immediate
area of nterded construction the tree shall be protected by
erc]c,;mq the entire circumference of the tree's trunk with umber
encircled with wire or other means that does not damage the tree
Refer to Tree Protector Detail(s)
14 Construction Prun,ng Ir- a case where a low hanging I,mb is broke-
during tr,,e course of construction the Contractor ssiall notify the
Landscape Architect mmed,ately In no instance shah the
Contractor prune any Portion of the damaged tree w thout the prior
approva by the Landscape Architect
TREE MITIGATION TABULATIONS
Gross Retribution P4"
Unlnusl
Total capper inches of trees
128"
saved (divided by(
REMARKS
Total caliper ncrles trees on site
52"
6" caliper plus at Breast Height
31 5
(equals)
21'
Preservation credit
84 2�,0
Mmes)
8
Gross retribution
24°
(equalsi
8
Preservatior Cred t
20°
(minus)
8
Landscaping Cited t
52 5"
(equals)
REMARKS
391 trees- 3" cal req by Ord harce
8
(21 i Lcb 3" cap i50- max 1
31 5
(21 ) trees O 1" cal above required
21'
Net Retrlb.,' oh
0„
TREE SURVEY FIELD DATA
NO.
DIA,
INCHES
SPECIES
(COMMON NAME)
REMARKS
101
8
PEAR
TO REMAIN
102
8
PEAR
TO BE REMOVED
103
8
PEAR
TO BE REMOVED
104
8
PEAR
TO REMAIN
105
8
PEAR
TO REMAIN
106
8
PEAR
TO BE REMOVED
107
5
PEAR
TO REMAIN
108
8
PEAR
TO REMAIN
109
8
OAK
TO REMAIN
110
8
OAK
TO REMAIN
111
8
OAK
TO REMAIN
112
8
OAK
TO REMAIN
113
8
OAK
TO REMAIN
114
8
OAK
TO REMAIN
115
8
OAK
TO REMAIN
116
8
OAK
TO REMAIN
117
8
OAK
TO REMAIN
118
8
OAK
TO REMAIN
119
8
OAK
TO REMAIN
120
8
OAK
TO REMAIN
157 CALIPER INCHES EXISTING TREES EXISTING ON S,TE
16 CAPER INCHES TREES TO BE REMOVED
19 TREES ARE OVER 6" CALIPER- BREAST HEIGHT
1 TREES ARE LESS THEN 6" CALIPER- BREAST HEIG'H1
TREES 6" CAL PER OR ABOVE AT BREAST HEIGHT ARE CALCULATED IN THE
TREE RETR BUTION CALCULATIONS
C
c
C
LIMITS OF DRIPLINE
TREE PROTECTIVE FENCING
01 NTH
EFER TO PLAN FOR
XISTING TREE TO REVA N
NOW FENCE ORANGE VINYL
ONSTRUCTION FENCE OR
H; INLINK FENCE
LISTING GRADE TO
=1vIAIN UNDISTURBED
cTAL T -POST AT
,CH OF FOUR CORNERS
T.��Wr� "
t�'
smr
landscape architects, inc.
1708 N Griffin Street
Dallas, Texas 75202
Tel 214 871-0083
Fax 214871 0545
Email smr a smr -la corn
W
U
N
U
L
9661 Audelia Road
Suite 333 -66
Dallas, Texas 75238
214.261.9060
tf#3�1i�.��� it�lc�ic.>�I
P r e s t o n
General Contractors
J
Q
W
W
05.29.2012
SHEET CONTENTS:
EXISTING TREE PLAN
DATE: April 18, 2012
SHEET: L1.00
0 COP7RI ;HT bat AZIM'. 1h Ar„ FITE, T I ,F qi