Illumination PlanWE
ILLUMINATION PLAN-
0 10 20 40 60
SCALE IN FEET
1 INCH = 20 FEET
EXTERIOR LIGHTING LAYOUT NOTES]
A. ALL EXTERIOR LIGHTS SHALL BE CONTROLLED VIA AUTOMATIC CONTROLS !PHOTOCELL /TIMECLOCKI PER
INTERNATIONAL ENERGY CONSERVATION CODE. LIGHTING CONTROLS SHALL BE DESIGNED BY OTHER.
B. EXTERIOR LIGHTING LAYOUT IS BASED ON THE FOLLOWING CRITIERIA.
1. 0.75 MAINTENANCE LIGHT LOST FACTOR.
ll. EACH POLE SHALL BE RATED TO HANDLE A MINIMUM OF 14.5 EPA WITH WIND SPEED OF l00 MPH.
C. THIS PLAN IS FOR GENERAL LIGHTING LAYOUT AND SPECIFICATIONS. THIS PLAN DOES NOT ADDRESS
0 RELATED DESIGN ISSUES INCLUDING LIGHTING CIRCUIT ASSIGNMENT, WIRING PLANS, CONDUIT
LAYOUT, LOAD ANALYSIS, OR GROUNDING REQUIREMENTS ASSOCIATED WITH POLE LIGHTS, POLE BASE,
OR ELECTRICAL POWER /CONTROLS. REFER TO MEP PLANS FOR THESE ASSOCIATED SPECIFICATIONS.
DECORA TI VE PAVERS
A T ENTRANCE
OWNE
6- ANTIQUE STYLE STREET
LIGHTS (SL )
APPLICANT:
P & V Mobile
Attn: Vicki Nevins
1091 Glen Rose Road
Stephenville, TX 76041
ataconst @aol.com
254 - 968 -5552
PREPARED BY:
K E L L I E
ENGINEERING, INC.
AN ME STYLE STREET LIGHT
NEW STREETLIGHTS TO BE SAME MODEL,
HEIGHT, AND COLOR AS EXISTING STREET
LIGHTS AT HARD EIGHT BBQ.
MAXIMUM TO TA POLE HEIGHT IS 12 ' -0 "
GENERAL NO TES +
A. COORDINATE INSTALLATION WITH STRUCTURAL, CIVIL, ARCHITECTURAL, MEP, AND LANDSCAPE PLANS.
B. POLE BASE ANCHOR BOLTS SHALL BE IN COMPLIANCE WITH MANUFACTURER'S SPECIFICATIONS,
BOLT SIZE, AND PATTERN.
P.O. Box 471898
FORT WORTH, TX 76147
TEL: 817.379.1225
FAX." 817.704,4458
ekelliei@kellie-engineering.com
FIRM NO. 7585
NOTES:
NO OUTDOOR SPEAKERS ALLOWED ON LIGHT STANDARDS
IN PARKING AREA ( LOT 2, BLOCK A, CRESCENT ADDITION)
!3E
LLAST
THERPROOF
TX FUSES
JUN 2 5 2014
CI 4 ' P C'OPPELL
PLANNING & ZONING DEPARTMENT
ILLUMINATION PLAN
HARD EIGHT BBQ - PARKING EXPANSION
LOTS 1 R & 2, BLOCK A, CRESCENT ADDITION
JAMES A. SIMMONS SURVEY, ABSTRACT 1296
CITY OF COPPELL, DALLAS COUNTY, TEXAS
2.982 ACRESY f
ISSUED: MAY 199 2014 t..
In