SP attached to CC Packet 070814Q
N
d-
0
CNE
Q
Cn
.3
Y
T
M
a
0
U)
Lid
J
Q
I—
w
Z
Q
J
a_
W
Cn
Ln
N
0
Ln
N
Cn
0
N
0
N
a
0
-- - -r -
(Ref. pot
FUTURE DRIVEWAY—
W/ ENHANCED PAVING
2' Conc.
Flume (Typ.)
' Overhang
"Part 1" of Access Easement Doc.
No.'s 200900132990 &
200900156683 R.P.R.D.C.T.
10' Storm Drain Easement
Doc. No.'s 200900132992
200900156682 R.P.R.D.C.T.
Prog. FH
X.
2' Conc.
Hume (Typ.)
� �'o� ,o
1� Fol
LID
2' Conc. ,o :. .•= =•.
ri.
:
erhan
9 _
.•Y r
.y.
Decorative Paving Per
City of Copell Details
15Utility Easement -
Plat Doc: 200900124402
Vicinity Map
NTS
inch = 40 ft.
GENERAL NOTES
1. Fire lanes shall be designed and constructed per City standards.
2. Handicapped parking areas shall be designed and provided per City standards and shall
comply with requirements of the current, adopted International Building Code.
3. Mechanical units, dumpsters and trash compactors shall be screened in accordance
with the Zoning Ordinance.
4. All signage contingent upon approval by Building Inspection Department.
5. All electrical transmission, distribution and service lines must be underground where
required.
6. All dimensions are to face of curb or edge of building unless otherwise noted.
Notes:
1. Handicap Parking Is Provided In
Accordance w/ ADA Standards.
2. No Floodplain Exists On The Site.
3. Site Plan Is For Informational Purposes
Only. It Is Not A Construction Document.
77
>=
Firelane,
SYNOM
Zoning
LOT 1 R1 A. BLOCK 1
PD-171R2—HC
Land Use
Office, Showroom, Warehouse
Lot Area
6.59 Ac. (287,270 Sq. Ft.)
Construction Type
IIB
Occupancy Type
S-1 & B
Building Footprint Area
80,980 Sq. Ft.
Building Height
36'-0"
Lot Coverage
28.29 Of Site
Floor Area Ratio
0.282:1
PARKING
Parking Ratio:
Office: 1 Sp./300 Sq. Ft.=34 Sp
DCV Development Dallas, LP
Showroom: 1 Sp./300 Sq. Ft.=50 Sp
724 Canyon Dr.
Warehouse: 1 Sp•/1,000 Sq. Ft.=55 Sp
Required Total otal Parking:
139 Spaces
Provided Total Parking:
171 Spaces (Incl. HC)
Accessible Parking Required
6 Spaces
Accessible Parking Provided
7 Spaces
77
>=
Firelane,
PD Conditions:
1. Proposed
use has greater than 20%
warehouse
Existing
2. Proposed
3. Proposed
buildinghas 10% masonry
y
site p Ian has greater than 50%
of parking
in the front of building.
O
F
77
>=
Firelane,
Access &
Utility Edserrr`errt. r
Existing
Contour
t x a :, • F•i. "? .� EPA,
1 Cf-`�.F s,NG I .ZONIN D P'-�
Engineer
Spiars Engineering, Inc.
TBPE No. F-2121
- 765 _ Custer Road, Suite 100
' gJ 3 Plano, Texas 75075
Telephone (972) 422-0077
f
Contact: Kevin Wier
v Lot I
Survey_
Miller Surveying, Inc.
430 Mid Cities Blvd.
Hurst, Texas 76054
Telephone (817) 577-1052
Scale 1"=40' May, 2014 SEI #12-154
I(f�
� u a
S H E E T
t x a :, • F•i. "? .� EPA,
1 Cf-`�.F s,NG I .ZONIN D P'-�
D E T A I L E D
S I T E P L A N
O
F
WISENBAKER OFFICE BUILDING
LOT 1 R1 A,
BLOCK 1
GTE SHARED SERVICES
CENTER ADDITION
COPPELL, DALLAS
COUNTY, TEXAS
Applicant
Owner
Azimuth Architecture, Inc.
DCV Development Dallas, LP
9661 Audelia Rd. Suite 123-66
724 Canyon Dr.
Dallas, TX 75238
Coppell, TX 75019
Telephone (214) 261-9060
Telephone (214) 520-7800
Contact: John Taylor
Engineer
Spiars Engineering, Inc.
TBPE No. F-2121
- 765 _ Custer Road, Suite 100
' gJ 3 Plano, Texas 75075
Telephone (972) 422-0077
f
Contact: Kevin Wier
v Lot I
Survey_
Miller Surveying, Inc.
430 Mid Cities Blvd.
Hurst, Texas 76054
Telephone (817) 577-1052
Scale 1"=40' May, 2014 SEI #12-154