Loading...
PL-Site PlanW 1VITA #17 — City of Coppell Aluminum marker set in the top of curb of the parking lot opposite the front doors of Wilson Elementary at 200 N. Coppell Rd., Approximately 36' (feet) east of the center line of said Coppell Rd. Elevation = 515.37 BM -1 "X" cut on top of the northeast corner of a concrete sidewalk on the east side of Freeport Pkwy., and south of the concrete driveway of the subject property. Elevation = 498.28 Note: Variance request from Light Industrial district to PD — delete masonry wall requirement between LI and SF zoning districts. Site Plan Conditions: VICINITY 1. Minor Plat approval will be required prior to the issuance of a building permit. 2. The design of the monument and attached signs shall comply with the regulations of the Sign Ordinance. 3. Trees retained along the north property line shall be mitigated if they do not survive construction. 4. The existing structure may be retained for a maximum of 120 days after the issuance of a certificate of occupancy on the new building. Once the structure is removed, it will be replaced with landscaped front yard and monument sign. 5. Hours of operation shall generally be 7:00 AM to 7:00 PM, but in no event shall there be any deliveries to the rear of the building between 7:00 PM and 7:00 AM and/or on the weekend or on major holidays. 6. Parking spaces shall be limited to amount and location indicated on the site plan. No parking shall be permitted on rear east side of proposed building. 7. No 18—wheeler semi—trucks shall be allowed on the property. 8. This property shall only be used for office, warehouse and light assembly, no manufacturing shall be permitted. 9. Sirens or loud truck alarms (except for those required for safety) shall not be permitted. 10. Lighting — Use the lowest amount of wattage necessary to maintain security in the rear of the building but to avoid light shining on to neighboring houses. ZONED: PD-109—SF-9 SYNOPSIS Iffirmalr 0 0 30 100 GRAPHIC SCALE 1 "=30' Address: 196 S. Freeport Parkway Coppell, Texas 75019 Ex. Zoning: LI — Light Industrial Prop. Zoning: PD — Planned Development Proposed`" Use: Office - W-cr-ehouse Lot Area: Total Lot Area: 3.148 Acres (137,125 sf) Total Flood Plain Area: 1.686 Acres (73,427 sf) Remainder Area: 1.462 Acres (63,698 sf) Building Areas: Building A — Office 10,500 sf Building A — Warehouse 5,145 sf Total Bldg Area: 15,645 sf Lot Coverage: 11.41% (Total Bldg Area 15,645 sf) Floor Area Ratio: 0.11 : 1 Building Height: 27' Required Parking: Prop Office 1:300 (10,500/300) =35 Spcs. Prop. Warehouse 1:1,000 (5,145/1,000) = 6 Spcs. Parking Required Total: (41 Parking Spaces) Parking Provided Total: (41 Parking Spaces) 2 Handicap Spc. ENGINEER: Cross Engineering Consultants, Inc. 131 S. Tennessee St. McKinney, Texas 75069 LEGEND. =- <{ Phone (972) 562-4409 H'U T4* Fax (972) 562-4471 Firelane PAC, ET Contact: Jon David Cross, P.E. ARCHITECT: = .. Proposed Sidewalk GPF Architects, LLC -3 509 W. Bethel Road, Bldg 100 Coppell, Texas 75019 -_ Existing Fire Hydrant Phone (972) 824-7966 '"`'"'" Fax (972) 462-1368 contact: Greg Fmka, AIA �- Proposed Fire Hydrant 201} SURVEYSEP OR -2 Bingley & Associates . 701 S. Tennessee St. F McKinney, TX. 75069 Phone (972) 542-1266 NOTE: THIS IS NOT A CONSTRUCTION DOCUMENT. ° ~972 542-8682 .a g. ma it Zi IN DL9 §i,.',,,.f px ( ) THIS DOCUMENT IS FOR CONCEPTUAL PLANNING PURPOSES ONLY. Contact: Lawrence Ringley