Loading...
Landscape Plan and Tree Survey (3 Pages)3 CE 1 CE REPAIR AND REPLACE EXISTING LANDSCAPE AS NEEDED (TYP.) EXISTING LANDSCAPING TO REMAIN (TYP.) EXISTING CREPE MYRTLE TO REMAIN (TYP.) EXISTING LANDSCAPING TO REMAIN(TYP.) EXISTING PAVING (TYP.) NEW BUILDING PHASE I (TYP.) REPAIR AND REPLACE EXISTING LANDSCAPE AS NEEDED (TYP.) EXISTING PARKING AREA NEW BUILDING PHASE II (TYP.) EXISTING STREET TREE TO REMAIN (TYP.) NEW PAVED AREA (TYP.) NEW PAVED AREA (TYP.) 3 ERC 3 ERC SCO P E O F W O R K SCOP E O F W O R K SCOPE OF WORKSCOPE OF WORKEXISTING PAVING (TYP.) 1 LO 1 LO 1 LO SCALE: 1" = 30'-0" LANDSCAPE PLAN01 ST ATE O F T E XAS0160 NEVET .M R A HNS01.10.17 S H E E T N U M B E R 130053 D E V E L O P E R 332 MACARTHUR BLVD.COPPELL, TX 75019 CHURCH OF THE APOSTLES A R C H I T E C T C V I L E N G I N E E R 111 WEST MAIN STREETALLEN, TEXAS 75013 RLK ENGINEERING, INC. 972.359.1733 800 JACKSON STREET | SUITE 500DALLAS, TEXAS 75202 5G STUDIO COLLABORATIVE 214.670.0050 214.502.2199 P R O J E C T N U M B E R CONTACT: SETH KELLY CONTACT: LEE CARROLL CONTACT: ERIC BARTLETT DRAWINGS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE ARCHITECT. THEY SHALL NOT BE USED, TRANSFERRED, OR SOLD FOR USE EXCEPT BY AN AGREEMENT IN WRITINGFROM THE ARCHITECT. 18104 S E A L ONG YEN ONG L A N D S C A P E A R C H I T E C T 1708 NORTH GRIFFIN ST.DALLAS, TX 75202 SMR LANDSCAPE ARCHITECTS INC. 214.871.0083CONTACT: HANK THOMAS REV. DATE ISSUE S T R U C T U R A L E N G I N E E R M E P E N G I N E E R 918 DRAGON STREET DALLAS, TX 75207 MEP SYSTEMS DESIGN AND 214.915.0929 CONTACT: MARK PORTNOY P R O J E C T A D D R E S S P R O J E C T COPPELL, TEXAS 75019 322 MACARTHUR BLVD. CHURCH OF THE APOSTLES ADDITION 400 CHISOLM PLACE, SUITE 106PLANO, TX 75075 214.253.2506 CONTACT: MOHAMMAD KABIR MK ENGINEERS AND ASSOCIATES, INC - 12.21.16 SITE PLAN SUBMITTAL ENGINEERING LOT 1, BLOCK A,CORPORATION OF THEEPISCOPAL DIOCESE OFDALLAS ADDITION L1.01 Provided Existing Trees Provided Existing Trees Provided Existing Trees Provided Existing Trees Provided 600 s.f. (40%) (0) trees, 3" cal. min. Provided 70,682 s.f. (59.0%) (7) trees, 3" cal. min. PERIMETER LANDSCAPE Requirements: Street Frontage shall contain a 15' landscape buffer with one (1) tree, 3" cal. 12" above ground, per 50 l.f. and 30" ht. parking lot screen: hedge or berm. Perimeter landscape areas shall contain a 10' landscape buffer along property lines with one (1) tree, 3" cal. 12" above ground, per 50 l.f. MacArthur Blvd: (292 l.f.) Scope of Work Required Starleaf St: (504 l.f.) Scope of Work Required East Property Line: (234 l.f.) Scope of Work Required South Property Line: (465 l.f.) Required INTERIOR LANDSCAPE Requirements: 10% of gross parking area to be landscape. One (1) tree per 400 s.f. of required landscape area. Parking Lot: 1,304 s.f. (New area added) Parking Spaces: 3 Required 130 s.f. (10%) (0) trees, 3" cal. OPEN SPACE Requirements: 15% of lot not covered by buildings to be landscape open space. One (1) tree per 2500 s.f. of open space. TOTAL LOT AREA: (Exclusive of building): 119,997 s.f. Required 17,999 s.f. (15%) (7) trees SUMMARY Total trees required: (7) trees Total trees provided: (7) trees, 3" cal. MAINTENANCE NOTES LANDSCAPE NOTES 1.The Owner, tenant and their agent, if any, shall be jointly and severally responsible for the maintenance of all landscape. 2. All landscape shall be maintained in a neat and orderly manner at all times. This shall include mowing, edging, pruning, fertilizing, watering, weeding and other such activities common to landscape maintenance. 3. All landscape areas shall be kept free of trash, litter, weeds and other such material or plants not part of this plan. 4. All plant material shall be maintained in a healthy and growing condition as is appropriate for the season of the year. 5. All plant material which dies shall be replaced with plant material of equal or better value. 6. Contractor shall provide separate bid proposal for one year's maintenance to begin after final acceptance. 1. Contractor shall verify all existing and proposed site elements and notify Architect of any discrepancies. Survey data of existing conditions was supplied by others. 2. Contractor shall locate all existing underground utilities and notify Architect of any conflicts. Contractor shall exercise caution when working in the vicinity of underground utilities. 3. Contractor is responsible for obtaining all required landscape and irrigation permits. 4. Contractor to provide a minimum 2% slope away from all structures. 5. All planting beds and lawn areas to be separated by steel edging. No steel to be installed adjacent to sidewalks or curbs. 6. All landscape areas to be 100% irrigated with an underground automatic irrigation system and shall include rain and freeze sensors. 7. All lawn areas to be Hydromulch Bermudagrass, unless otherwise noted on the drawings. BOTANICAL NAME Ulmus crassifolia Juniperius virginiana Ouercuse virginiana COMMON NAME Cedar Elm Eastern Red Cedar Live Oak QTY. 4 6 3 SIZE 3" cal. 6' ht. 3" cal. PLANT LIST REMARKS B&B or container grown, 12' ht. min. 4' spread min. container grown, cull to base, 3'; spread B&B or container grown, 12' ht. min. 4' spread min. TYPE CE ERC LO TREES NOTE: Plant list is an aid to bidders only. Contractor shall verify all quantities on plan. All heights and spreads are minimums. All plant material shall meet or exceed remarks as indicated. All trees to have straight trunks and be matching within varieties. LANDSCAPE PLAN Trees to be Installed 1 01.05.07 DRC COMMENTS 2 01.10.07 P AND Z Exhibit "C" 1 of 3 ST ATE O F T E XAS0160 NEVET .M R A HNS01 10 17 1.Existing trees to remain shall be protected during construction from tree structure damage and compaction of soil under and around dripline (canopy) of tree. 2. If any root structure is damaged during adjacent excavation/construction, notify the Architect immediately. It is recommended that a licensed Arborist be secured for the treatment of any possible tree wounds. 3. No disturbance of the soil greater than 4" shall be located closer to the tree trunk than 1/2 the distance of the drip line to the tree trunk. A minimum of 75% of the drip line and root zone shall be preserved at natural grade. 4. Any fine grading done within the critical root zones of the protected trees must be done with light machinery such as a bobcat or light tractor. No earth moving equipment with tracks is allowed within the critical root zone of the trees. 5. Material Storage: No materials intended for use in construction or waste materials accumulated due to excavation or demolition shall be placed within the limits of the dripline of any tree. 6. Equipment Cleaning/Liquid Disposal: No equipment may be cleaned, toxic solutions, or other liquid chemicals shall be deposited within the limits of the dripline of a tree. This would include but not be limited to paint, oil, solvents, asphalt, concrete, mortar, primers, etc. 7. Tree Attachments: No signs, wires or other attachments, other than those of a protective nature shall be attached to any tree. 8. Vehicular Traffic: No vehicular and construction equipment traffic or parking is allowed within the limits of the dripline of trees. 9. Boring of Utilities: May be permitted under protected trees in certain circumstances. The minimum length of the bore shall be the width of the tree's canopy and shall be a minimum depth of forty-eight (48") inches. 10. Trenching: Any irrigation trenching which must be done within the critical root zone of a tree shall be dug by hand and enter the area in a radial manner. 11. Tree Flagging: All trees to be removed from the site shall be flagged by the Contractor with bright red vinyl tape (3" width) wrapped around the main trunk at a height of four (4') feet above grade. Flagging shall be approved by Landscape Architect prior to any tree removal. Contractor shall contact Landscape Architect with 72 hour notice to schedule on-site meeting. 12. Protective Fencing: All trees to remain, as noted on drawings, shall have protective fencing located at the tree's dripline. The protective fencing may be comprised of snow fencing, orange vinyl construction fencing, chain link fence or other similar fencing with a four (4') foot approximate height. The protective fencing will be located as indicated on the Tree Protection Detail(s). 13. Bark Protection: In situations where a tree remains in the immediate area of intended construction, the tree shall be protected by enclosing the entire circumference of the tree's trunk with lumber encircled with wire or other means that does not damage the tree. Refer to Tree Protection Detail(s). 14. Construction Pruning: In a case where a low hanging limb is broken during the course of construction, the Contractor shall notify the Landscape Architect immediately. In no instance shall the Contractor prune any portion of the damaged tree without the prior approval by the Landscape Architect. EXISTING TREE NOTES NOTE: A" REMOVE BULKY TREE PARTS "SHRED" AND/OR HAUL SEPARATELY. "B" BEGIN EXCAVATION APPROX. 8' FROM THE TRUNK - CUT THRU ANCHOR ROOTS AT AN ANGLE - 3' TO 4' DEEP "C" USING TREE TRUNK AS A LEVER PUSH AT POINT "E" TO REMOVE TREE BOLE AND LARGE FEEDER ROOTS (4" TO 10" IN DIAM.) "D" BACKFILL HOLE AND CLEAN UP. "B" ABSORBING ROOTS GRADE"C""C""B" "A" "A" 4' 2X4 4' 4" 02 TREE PROTECTION FENCE B 03 TREE REMOVAL DIAGRAM 01 TREE PROTECTION FENCE A NOTE: WRAP TREE TRUNK WITH 2 X 4 STUDS AND ROPE OR BAND IN-PLACE AS NEEDED TO PROTECT TREES IN WORK AREAS NOTE: FENCING SHOWN ABOVE IS DIAGRAMMATIC ONLY AND WILL CONFORM TO THE DRIP LINE AND LIMITED TO PROJECT BOUNDARY 04 ROOT PRUNING DETAIL S H E E T N U M B E R 130053 D E V E L O P E R 332 MACARTHUR BLVD.COPPELL, TX 75019 CHURCH OF THE APOSTLES A R C H I T E C T C V I L E N G I N E E R 111 WEST MAIN STREETALLEN, TEXAS 75013 RLK ENGINEERING, INC. 972.359.1733 800 JACKSON STREET | SUITE 500DALLAS, TEXAS 75202 5G STUDIO COLLABORATIVE 214.670.0050 214.502.2199 P R O J E C T N U M B E R CONTACT: SETH KELLY CONTACT: LEE CARROLL CONTACT: ERIC BARTLETT DRAWINGS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE ARCHITECT. THEY SHALL NOT BE USED, TRANSFERRED, OR SOLD FOR USE EXCEPT BY AN AGREEMENT IN WRITINGFROM THE ARCHITECT. 18104 S E A L ONG YEN ONG L A N D S C A P E A R C H I T E C T 1708 NORTH GRIFFIN ST.DALLAS, TX 75202 SMR LANDSCAPE ARCHITECTS INC. 214.871.0083CONTACT: HANK THOMAS REV. DATE ISSUE S T R U C T U R A L E N G I N E E R M E P E N G I N E E R 918 DRAGON STREET DALLAS, TX 75207 MEP SYSTEMS DESIGN AND 214.915.0929 CONTACT: MARK PORTNOY P R O J E C T A D D R E S S P R O J E C T COPPELL, TEXAS 75019 322 MACARTHUR BLVD. CHURCH OF THE APOSTLES ADDITION 400 CHISOLM PLACE, SUITE 106PLANO, TX 75075 214.253.2506 CONTACT: MOHAMMAD KABIR MK ENGINEERS AND ASSOCIATES, INC - 12.2116 SITE PLAN SUBMITTAL ENGINEERING LOT 1, BLOCK A,CORPORATION OF THEEPISCOPAL DIOCESE OFDALLAS ADDITION L1.02 LANDSCAPE SPECIFICATION07TREE PLANTING DETAIL 05 SIDEWALK / MULCH DETAIL 09 STEEL EDGING DETAIL 06 SHRUB PLANTING DETAIL 12" MIN EDGE OF BED DD D A A PLANT ROW SPACING 'D' ROW SPACING 'A' PLANTS/10SF 8" O.C. 12" O.C. 15" O.C. 18" O.C. 6.9" 10.4" 13.0" 15.7" 26 12 7 5 08 GROUNDCOVER PLANTING DETAIL 1 01.05.07 DRC COMMENTS 2 01.10.07 P AND Zge 1 of 2 Exhibit"C" page 2 of 3 SCO P E O F W O R K SCOP E O F W O R K SCOPE OF WORKSCOPE OF WORK#1 #2 #3 #4 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16 #17 #18 #19 #20 #21 #22 #23 #24 #25 #26 #27 #28 #29 #30 #31 #5 #32 #33 #34 #35 #36 #37 #38 #39 #40 #44 #45 #46 #47 #41 #42 #43 EXISTING CREPE MYRTLE TO REMAIN (TYP.) EXISTING CREPE MYRTLE TO BE REMOVED (TYP.) EXISTING HOLLIES TO REMAIN (TYP.) EXISTING HOLLIES TO BE REMOVED (TYP.) SCALE: 1" = 30'-0" TREE RETRIBUTION PLAN01 ST ATE O F T E XAS0160 NEVET .M R A HNS01 10 17 1 Multi-trunk Live Oak 18" Protected Saved 2 Multi-trunk Live Oak 18" Protected Saved 3 Single trunk Live Oak 24" Protected Saved 4 Single trunk Live Oak 14" Protected Saved 5 Multi-trunk Live Oak 18" Protected Saved 6 Single trunk Pistashe 8" Protected Saved 7 Single trunk Pistache 10" Protected Saved 8 Single trunk Pistache 8" Protected Saved 9 Single trunk Red Oak 6" Protected Saved 10 Single trunk Red Oak 8" Protected Saved 11 Single trunk R Maple 10" Protected Saved 12 Single trunk Red Oak 8" Protected Saved 13 Single trunk Elm 10" Protected Saved 14 Single trunk Elm 12" Protected Saved 15 Single trunk Elm 12" Protected Saved 16 Single trunk Elm 8" Protected Saved 17 Single trunk Elm 8" Protected Removed 18 Single trunk Live Oak 14" Protected Removed 19 Single trunk Pistache 12" Protected Removed 20 Single trunk Pistache 14" Protected Removed 21 Single trunk Red Oak 12" Protected Removed 22 Single trunk Red Oak 10" Protected Saved 23 Single trunk Red Oak 10" Protected Saved 24 Single trunk Live Oak 12" Protected Saved 25 Multi-trunk Live Oak 10" Protected Saved 26 Single trunk Red Oak 6" Protected Saved 27 Single trunk Red Oak 14" Protected Saved 28 Multi-trunk Live Oak 16" Protected Saved 29 Single trunk Live Oak 12" Protected Saved 30 Single trunk Live Oak 8" Protected Saved 31 Single trunk Cypress 12" Protected Saved 32 Single trunk Red Oak 10" Protected Saved 33 Single trunk Red Oak 10" Protected Saved 34 Single trunk Red Oak 12" Protected Saved 35 Multi-trunk Red Oak 6" Protected Saved 36 Single trunk Red Oak 8" Protected Saved 37 Single trunk Red Oak 6" Protected Saved 38 Single trunk Red Oak 8" Protected Saved 39 Multi-trunk Red Oak 6" Protected Saved 40 Single trunk Live Oak 10" Protected Saved 41 Single trunk Live Oak 8" Protected Saved 42 Single trunk Live Oak 10" Protected Saved 43 Single trunk Live Oak 18" Protected Saved 44 Single trunk Elm 12" Protected Saved 45 Single trunk Elm 10" Protected Saved 46 Single trunk Elm 8" Protected Saved 47 Single trunk Elm 10" Protected Saved 514 - 0" + 454" +10 -60" + 7" +21 -3" TREE TABULATIONS Total caliper inches of trees on site Total caliper inches of protected trees removed (6" cal. and greater) Total caliper inches of unprotected trees removed (Unprotected trees less than 10") Total caliper inches of trees saved (6" and greater) Preservation credit .883 Required retribution Total caliper inches of trees provided (refer to landscape plan) Total caliper inches of trees provided applied towards landscape credit (up to one half of retribution) Total caliper inches of trees required for retribution TREE LIST EXISTING TREE TO BE REMOVED EXISTING TREE TO REMAIN EXISTING TREE LEGEND S H E E T N U M B E R 130053 D E V E L O P E R 332 MACARTHUR BLVD.COPPELL, TX 75019 CHURCH OF THE APOSTLES A R C H I T E C T C V I L E N G I N E E R 111 WEST MAIN STREETALLEN, TEXAS 75013 RLK ENGINEERING, INC. 972.359.1733 800 JACKSON STREET | SUITE 500DALLAS, TEXAS 75202 5G STUDIO COLLABORATIVE 214.670.0050 214.502.2199 P R O J E C T N U M B E R CONTACT: SETH KELLY CONTACT: LEE CARROLL CONTACT: ERIC BARTLETT DRAWINGS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE ARCHITECT. THEY SHALL NOT BE USED, TRANSFERRED, OR SOLD FOR USE EXCEPT BY AN AGREEMENT IN WRITINGFROM THE ARCHITECT. 18104 S E A L ONG YEN ONG L A N D S C A P E A R C H I T E C T 1708 NORTH GRIFFIN ST.DALLAS, TX 75202 SMR LANDSCAPE ARCHITECTS INC. 214.871.0083CONTACT: HANK THOMAS REV. DATE ISSUE S T R U C T U R A L E N G I N E E R M E P E N G I N E E R 918 DRAGON STREET DALLAS, TX 75207 MEP SYSTEMS DESIGN AND 214.915.0929 CONTACT: MARK PORTNOY P R O J E C T A D D R E S S P R O J E C T COPPELL, TEXAS 75019 322 MACARTHUR BLVD. CHURCH OF THE APOSTLES ADDITION 400 CHISOLM PLACE, SUITE 106PLANO, TX 75075 214.253.2506 CONTACT: MOHAMMAD KABIR MK ENGINEERS AND ASSOCIATES, INC - 12.21.16 SITE PLAN SUBMITTAL ENGINEERING LOT 1, BLOCK A,CORPORATION OF THEEPISCOPAL DIOCESE OFDALLAS ADDITION L0.01 TREE RETRIBUTION PLAN 1 01.05.07 DRC COMMENTS 2 01.10.07 P AND ZExhibit"C" page 3 of 3