Landscape Plan and Tree Survey (3 Pages)3
CE
1
CE
REPAIR AND REPLACE
EXISTING LANDSCAPE AS
NEEDED (TYP.)
EXISTING LANDSCAPING
TO REMAIN (TYP.)
EXISTING CREPE MYRTLE
TO REMAIN (TYP.)
EXISTING LANDSCAPING
TO REMAIN(TYP.)
EXISTING
PAVING
(TYP.)
NEW BUILDING
PHASE I (TYP.)
REPAIR AND REPLACE
EXISTING LANDSCAPE AS
NEEDED (TYP.)
EXISTING PARKING AREA
NEW BUILDING
PHASE II (TYP.)
EXISTING STREET TREE
TO REMAIN (TYP.)
NEW PAVED AREA (TYP.)
NEW PAVED AREA (TYP.)
3
ERC
3
ERC
SCO
P
E
O
F
W
O
R
K
SCOP
E
O
F
W
O
R
K SCOPE OF WORKSCOPE OF WORKEXISTING
PAVING
(TYP.)
1
LO
1
LO
1
LO
SCALE: 1" = 30'-0"
LANDSCAPE PLAN01 ST
ATE O F T E XAS0160
NEVET .M R
A
HNS01.10.17
S H E E T N U M B E R
130053
D E V E L O P E R
332 MACARTHUR BLVD.COPPELL, TX 75019
CHURCH OF THE APOSTLES
A R C H I T E C T
C V I L E N G I N E E R
111 WEST MAIN STREETALLEN, TEXAS 75013
RLK ENGINEERING, INC.
972.359.1733
800 JACKSON STREET | SUITE 500DALLAS, TEXAS 75202
5G STUDIO COLLABORATIVE
214.670.0050
214.502.2199
P R O J E C T N U M B E R
CONTACT: SETH KELLY
CONTACT: LEE CARROLL
CONTACT: ERIC BARTLETT
DRAWINGS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE ARCHITECT. THEY SHALL NOT BE USED, TRANSFERRED, OR SOLD FOR USE EXCEPT BY AN AGREEMENT IN WRITINGFROM THE ARCHITECT.
18104
S E A L
ONG YEN ONG
L A N D S C A P E A R C H I T E C T
1708 NORTH GRIFFIN ST.DALLAS, TX 75202
SMR LANDSCAPE ARCHITECTS INC.
214.871.0083CONTACT: HANK THOMAS
REV. DATE ISSUE
S T R U C T U R A L E N G I N E E R
M E P E N G I N E E R
918 DRAGON STREET
DALLAS, TX 75207
MEP SYSTEMS DESIGN AND
214.915.0929
CONTACT: MARK PORTNOY
P R O J E C T A D D R E S S
P R O J E C T
COPPELL, TEXAS 75019
322 MACARTHUR BLVD.
CHURCH OF THE
APOSTLES ADDITION
400 CHISOLM PLACE, SUITE 106PLANO, TX 75075
214.253.2506 CONTACT: MOHAMMAD KABIR
MK ENGINEERS AND ASSOCIATES, INC
- 12.21.16 SITE PLAN SUBMITTAL
ENGINEERING
LOT 1, BLOCK A,CORPORATION OF THEEPISCOPAL DIOCESE OFDALLAS ADDITION
L1.01
Provided
Existing Trees
Provided
Existing Trees
Provided
Existing Trees
Provided
Existing Trees
Provided
600 s.f. (40%)
(0) trees, 3" cal. min.
Provided
70,682 s.f. (59.0%)
(7) trees, 3" cal. min.
PERIMETER LANDSCAPE
Requirements: Street Frontage shall contain a 15' landscape buffer
with one (1) tree, 3" cal. 12" above ground, per 50 l.f. and 30" ht.
parking lot screen: hedge or berm. Perimeter landscape areas shall
contain a 10' landscape buffer along property lines with one (1) tree,
3" cal. 12" above ground, per 50 l.f.
MacArthur Blvd: (292 l.f.) Scope of Work
Required
Starleaf St: (504 l.f.) Scope of Work
Required
East Property Line: (234 l.f.) Scope of Work
Required
South Property Line: (465 l.f.)
Required
INTERIOR LANDSCAPE
Requirements: 10% of gross parking area to be landscape. One (1)
tree per 400 s.f. of required landscape area.
Parking Lot: 1,304 s.f. (New area added)
Parking Spaces: 3
Required
130 s.f. (10%)
(0) trees, 3" cal.
OPEN SPACE
Requirements: 15% of lot not covered by buildings to be landscape
open space. One (1) tree per 2500 s.f. of open space.
TOTAL LOT AREA: (Exclusive of building):
119,997 s.f.
Required
17,999 s.f. (15%)
(7) trees
SUMMARY
Total trees required: (7) trees
Total trees provided: (7) trees, 3" cal.
MAINTENANCE NOTES
LANDSCAPE NOTES
1.The Owner, tenant and their agent, if any, shall be jointly and severally
responsible for the maintenance of all landscape.
2. All landscape shall be maintained in a neat and orderly manner at all times.
This shall include mowing, edging, pruning, fertilizing, watering, weeding and
other such activities common to landscape maintenance.
3. All landscape areas shall be kept free of trash, litter, weeds and other such
material or plants not part of this plan.
4. All plant material shall be maintained in a healthy and growing condition as is
appropriate for the season of the year.
5. All plant material which dies shall be replaced with plant material of equal or
better value.
6. Contractor shall provide separate bid proposal for one year's maintenance to
begin after final acceptance.
1. Contractor shall verify all existing and proposed site elements and notify
Architect of any discrepancies. Survey data of existing conditions was
supplied by others.
2. Contractor shall locate all existing underground utilities and notify Architect of
any conflicts. Contractor shall exercise caution when working in the vicinity of
underground utilities.
3. Contractor is responsible for obtaining all required landscape and irrigation
permits.
4. Contractor to provide a minimum 2% slope away from all structures.
5. All planting beds and lawn areas to be separated by steel edging. No steel to
be installed adjacent to sidewalks or curbs.
6. All landscape areas to be 100% irrigated with an underground automatic
irrigation system and shall include rain and freeze sensors.
7. All lawn areas to be Hydromulch Bermudagrass, unless otherwise noted on
the drawings.
BOTANICAL NAME
Ulmus crassifolia
Juniperius virginiana
Ouercuse virginiana
COMMON NAME
Cedar Elm
Eastern Red Cedar
Live Oak
QTY.
4
6
3
SIZE
3" cal.
6' ht.
3" cal.
PLANT LIST
REMARKS
B&B or container grown, 12' ht. min. 4' spread min.
container grown, cull to base, 3'; spread
B&B or container grown, 12' ht. min. 4' spread min.
TYPE
CE
ERC
LO
TREES
NOTE: Plant list is an aid to bidders only. Contractor shall verify all quantities on plan. All heights and spreads are
minimums. All plant material shall meet or exceed remarks as indicated. All trees to have straight trunks and be matching
within varieties.
LANDSCAPE PLAN
Trees to be Installed
1 01.05.07 DRC COMMENTS
2 01.10.07 P AND Z
Exhibit "C" 1 of 3
ST
ATE O F T E XAS0160
NEVET .M R
A
HNS01 10 17
1.Existing trees to remain shall be protected during construction from tree
structure damage and compaction of soil under and around dripline (canopy)
of tree.
2. If any root structure is damaged during adjacent excavation/construction,
notify the Architect immediately. It is recommended that a licensed Arborist
be secured for the treatment of any possible tree wounds.
3. No disturbance of the soil greater than 4" shall be located closer to the tree
trunk than 1/2 the distance of the drip line to the tree trunk. A minimum of
75% of the drip line and root zone shall be preserved at natural grade.
4. Any fine grading done within the critical root zones of the protected trees
must be done with light machinery such as a bobcat or light tractor. No earth
moving equipment with tracks is allowed within the critical root zone of the
trees.
5. Material Storage: No materials intended for use in construction or waste
materials accumulated due to excavation or demolition shall be placed within
the limits of the dripline of any tree.
6. Equipment Cleaning/Liquid Disposal: No equipment may be cleaned, toxic
solutions, or other liquid chemicals shall be deposited within the limits of the
dripline of a tree. This would include but not be limited to paint, oil, solvents,
asphalt, concrete, mortar, primers, etc.
7. Tree Attachments: No signs, wires or other attachments, other than those of
a protective nature shall be attached to any tree.
8. Vehicular Traffic: No vehicular and construction equipment traffic or parking
is allowed within the limits of the dripline of trees.
9. Boring of Utilities: May be permitted under protected trees in certain
circumstances. The minimum length of the bore shall be the width of the
tree's canopy and shall be a minimum depth of forty-eight (48") inches.
10. Trenching: Any irrigation trenching which must be done within the critical
root zone of a tree shall be dug by hand and enter the area in a radial
manner.
11. Tree Flagging: All trees to be removed from the site shall be flagged by the
Contractor with bright red vinyl tape (3" width) wrapped around the main
trunk at a height of four (4') feet above grade. Flagging shall be approved by
Landscape Architect prior to any tree removal. Contractor shall contact
Landscape Architect with 72 hour notice to schedule on-site meeting.
12. Protective Fencing: All trees to remain, as noted on drawings, shall have
protective fencing located at the tree's dripline. The protective fencing may
be comprised of snow fencing, orange vinyl construction fencing, chain link
fence or other similar fencing with a four (4') foot approximate height. The
protective fencing will be located as indicated on the Tree Protection
Detail(s).
13. Bark Protection: In situations where a tree remains in the immediate area of
intended construction, the tree shall be protected by enclosing the entire
circumference of the tree's trunk with lumber encircled with wire or other
means that does not damage the tree. Refer to Tree Protection Detail(s).
14. Construction Pruning: In a case where a low hanging limb is broken during
the course of construction, the Contractor shall notify the Landscape
Architect immediately. In no instance shall the Contractor prune any portion
of the damaged tree without the prior approval by the Landscape Architect.
EXISTING TREE NOTES
NOTE:
A" REMOVE BULKY TREE PARTS "SHRED" AND/OR HAUL SEPARATELY.
"B" BEGIN EXCAVATION APPROX. 8' FROM THE TRUNK - CUT THRU ANCHOR
ROOTS AT AN ANGLE - 3' TO 4' DEEP
"C" USING TREE TRUNK AS A LEVER PUSH AT POINT "E" TO REMOVE TREE
BOLE AND LARGE FEEDER ROOTS (4" TO 10" IN DIAM.)
"D" BACKFILL HOLE AND CLEAN UP.
"B"
ABSORBING ROOTS
GRADE"C""C""B"
"A"
"A"
4'
2X4
4'
4"
02 TREE PROTECTION FENCE B
03 TREE REMOVAL DIAGRAM
01 TREE PROTECTION FENCE A
NOTE:
WRAP TREE TRUNK WITH 2 X 4 STUDS AND ROPE OR BAND IN-PLACE
AS NEEDED TO PROTECT TREES IN WORK AREAS
NOTE:
FENCING SHOWN ABOVE IS DIAGRAMMATIC ONLY
AND WILL CONFORM TO THE DRIP LINE AND LIMITED
TO PROJECT BOUNDARY
04 ROOT PRUNING DETAIL
S H E E T N U M B E R
130053
D E V E L O P E R
332 MACARTHUR BLVD.COPPELL, TX 75019
CHURCH OF THE APOSTLES
A R C H I T E C T
C V I L E N G I N E E R
111 WEST MAIN STREETALLEN, TEXAS 75013
RLK ENGINEERING, INC.
972.359.1733
800 JACKSON STREET | SUITE 500DALLAS, TEXAS 75202
5G STUDIO COLLABORATIVE
214.670.0050
214.502.2199
P R O J E C T N U M B E R
CONTACT: SETH KELLY
CONTACT: LEE CARROLL
CONTACT: ERIC BARTLETT
DRAWINGS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE ARCHITECT. THEY SHALL NOT BE USED, TRANSFERRED, OR SOLD FOR USE EXCEPT BY AN AGREEMENT IN WRITINGFROM THE ARCHITECT.
18104
S E A L
ONG YEN ONG
L A N D S C A P E A R C H I T E C T
1708 NORTH GRIFFIN ST.DALLAS, TX 75202
SMR LANDSCAPE ARCHITECTS INC.
214.871.0083CONTACT: HANK THOMAS
REV. DATE ISSUE
S T R U C T U R A L E N G I N E E R
M E P E N G I N E E R
918 DRAGON STREET
DALLAS, TX 75207
MEP SYSTEMS DESIGN AND
214.915.0929
CONTACT: MARK PORTNOY
P R O J E C T A D D R E S S
P R O J E C T
COPPELL, TEXAS 75019
322 MACARTHUR BLVD.
CHURCH OF THE
APOSTLES ADDITION
400 CHISOLM PLACE, SUITE 106PLANO, TX 75075
214.253.2506 CONTACT: MOHAMMAD KABIR
MK ENGINEERS AND ASSOCIATES, INC
- 12.2116 SITE PLAN SUBMITTAL
ENGINEERING
LOT 1, BLOCK A,CORPORATION OF THEEPISCOPAL DIOCESE OFDALLAS ADDITION
L1.02
LANDSCAPE
SPECIFICATION07TREE PLANTING DETAIL
05 SIDEWALK / MULCH DETAIL
09 STEEL EDGING DETAIL
06 SHRUB PLANTING DETAIL
12" MIN EDGE OF BED
DD
D
A
A
PLANT ROW SPACING 'D' ROW SPACING 'A' PLANTS/10SF
8" O.C.
12" O.C.
15" O.C.
18" O.C.
6.9"
10.4"
13.0"
15.7"
26
12
7
5
08 GROUNDCOVER PLANTING DETAIL 1 01.05.07 DRC COMMENTS
2 01.10.07 P AND Zge 1 of 2 Exhibit"C" page 2 of 3
SCO
P
E
O
F
W
O
R
K
SCOP
E
O
F
W
O
R
K SCOPE OF WORKSCOPE OF WORK#1
#2
#3
#4
#6
#7
#8
#9
#10
#11
#12
#13 #14 #15
#16
#17
#18
#19
#20
#21
#22
#23
#24
#25
#26
#27
#28
#29
#30 #31
#5
#32
#33
#34
#35
#36
#37 #38 #39
#40
#44
#45
#46
#47
#41
#42
#43
EXISTING CREPE MYRTLE
TO REMAIN (TYP.)
EXISTING CREPE
MYRTLE TO BE
REMOVED (TYP.)
EXISTING HOLLIES TO
REMAIN (TYP.)
EXISTING HOLLIES TO
BE REMOVED (TYP.)
SCALE: 1" = 30'-0"
TREE RETRIBUTION PLAN01 ST
ATE O F T E XAS0160
NEVET .M R
A
HNS01 10 17
1 Multi-trunk Live Oak 18" Protected Saved
2 Multi-trunk Live Oak 18" Protected Saved
3 Single trunk Live Oak 24" Protected Saved
4 Single trunk Live Oak 14" Protected Saved
5 Multi-trunk Live Oak 18" Protected Saved
6 Single trunk Pistashe 8" Protected Saved
7 Single trunk Pistache 10" Protected Saved
8 Single trunk Pistache 8" Protected Saved
9 Single trunk Red Oak 6" Protected Saved
10 Single trunk Red Oak 8" Protected Saved
11 Single trunk R Maple 10" Protected Saved
12 Single trunk Red Oak 8" Protected Saved
13 Single trunk Elm 10" Protected Saved
14 Single trunk Elm 12" Protected Saved
15 Single trunk Elm 12" Protected Saved
16 Single trunk Elm 8" Protected Saved
17 Single trunk Elm 8" Protected Removed
18 Single trunk Live Oak 14" Protected Removed
19 Single trunk Pistache 12" Protected Removed
20 Single trunk Pistache 14" Protected Removed
21 Single trunk Red Oak 12" Protected Removed
22 Single trunk Red Oak 10" Protected Saved
23 Single trunk Red Oak 10" Protected Saved
24 Single trunk Live Oak 12" Protected Saved
25 Multi-trunk Live Oak 10" Protected Saved
26 Single trunk Red Oak 6" Protected Saved
27 Single trunk Red Oak 14" Protected Saved
28 Multi-trunk Live Oak 16" Protected Saved
29 Single trunk Live Oak 12" Protected Saved
30 Single trunk Live Oak 8" Protected Saved
31 Single trunk Cypress 12" Protected Saved
32 Single trunk Red Oak 10" Protected Saved
33 Single trunk Red Oak 10" Protected Saved
34 Single trunk Red Oak 12" Protected Saved
35 Multi-trunk Red Oak 6" Protected Saved
36 Single trunk Red Oak 8" Protected Saved
37 Single trunk Red Oak 6" Protected Saved
38 Single trunk Red Oak 8" Protected Saved
39 Multi-trunk Red Oak 6" Protected Saved
40 Single trunk Live Oak 10" Protected Saved
41 Single trunk Live Oak 8" Protected Saved
42 Single trunk Live Oak 10" Protected Saved
43 Single trunk Live Oak 18" Protected Saved
44 Single trunk Elm 12" Protected Saved
45 Single trunk Elm 10" Protected Saved
46 Single trunk Elm 8" Protected Saved
47 Single trunk Elm 10" Protected Saved
514
- 0"
+ 454"
+10
-60"
+ 7"
+21
-3"
TREE TABULATIONS
Total caliper inches of trees on site
Total caliper inches of protected trees
removed (6" cal. and greater)
Total caliper inches of unprotected trees
removed (Unprotected trees less than 10")
Total caliper inches of trees saved
(6" and greater)
Preservation credit .883
Required retribution
Total caliper inches of trees provided
(refer to landscape plan)
Total caliper inches of trees provided
applied towards landscape credit
(up to one half of retribution)
Total caliper inches of trees required
for retribution
TREE LIST
EXISTING TREE
TO BE REMOVED
EXISTING TREE
TO REMAIN
EXISTING TREE LEGEND
S H E E T N U M B E R
130053
D E V E L O P E R
332 MACARTHUR BLVD.COPPELL, TX 75019
CHURCH OF THE APOSTLES
A R C H I T E C T
C V I L E N G I N E E R
111 WEST MAIN STREETALLEN, TEXAS 75013
RLK ENGINEERING, INC.
972.359.1733
800 JACKSON STREET | SUITE 500DALLAS, TEXAS 75202
5G STUDIO COLLABORATIVE
214.670.0050
214.502.2199
P R O J E C T N U M B E R
CONTACT: SETH KELLY
CONTACT: LEE CARROLL
CONTACT: ERIC BARTLETT
DRAWINGS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE ARCHITECT. THEY SHALL NOT BE USED, TRANSFERRED, OR SOLD FOR USE EXCEPT BY AN AGREEMENT IN WRITINGFROM THE ARCHITECT.
18104
S E A L
ONG YEN ONG
L A N D S C A P E A R C H I T E C T
1708 NORTH GRIFFIN ST.DALLAS, TX 75202
SMR LANDSCAPE ARCHITECTS INC.
214.871.0083CONTACT: HANK THOMAS
REV. DATE ISSUE
S T R U C T U R A L E N G I N E E R
M E P E N G I N E E R
918 DRAGON STREET
DALLAS, TX 75207
MEP SYSTEMS DESIGN AND
214.915.0929
CONTACT: MARK PORTNOY
P R O J E C T A D D R E S S
P R O J E C T
COPPELL, TEXAS 75019
322 MACARTHUR BLVD.
CHURCH OF THE
APOSTLES ADDITION
400 CHISOLM PLACE, SUITE 106PLANO, TX 75075
214.253.2506 CONTACT: MOHAMMAD KABIR
MK ENGINEERS AND ASSOCIATES, INC
- 12.21.16 SITE PLAN SUBMITTAL
ENGINEERING
LOT 1, BLOCK A,CORPORATION OF THEEPISCOPAL DIOCESE OFDALLAS ADDITION
L0.01
TREE RETRIBUTION
PLAN
1 01.05.07 DRC COMMENTS
2 01.10.07 P AND ZExhibit"C" page 3 of 3