Loading...
Preliminary Utility PlanX-Cut Set X-Cut Set Cappe d IRF SSMH Top=46 7 . 3 4 Fl=464 . 1 4 STATE HIGHWAY NO. 121 (VARIABLE WIDTH RIGHT OF WAY) Volume 97149, Page 460 (OPRDCT) & cc# 97-R0051944 (RPRDCT) Lot 5R, Block A North Gateway Plaza Inst. No. 201100023079 (OPRDCT) Existing Zoning: PD-240R-HC Lot 6, B l o c k A North G a t e w a y P l a z a Inst. N o . 2 0 1 2 0 0 0 5 5 4 9 5 (OPRD C T ) Exisiti n g Z o n i n g : R 3 Fire Lane & Mutual Access EasementInst. No. 201200055495 10' Private Water EasementInst. No. 201200055495 15' Pri v a t e D r a i n a g e E a s e m e n t Inst. N o . 2 0 1 2 0 0 0 5 5 4 9 5 20' Private Water Easement Inst. No. 200900228162 10' Pedestrian Access EasementInst. No. 200900228162 20' Electric Esmt Volume 99036, Page 808 (OPRDCT) Volume 99054, Page 1401 (OPRDCT)Volume 4300, Page 329 (RPRDCT)Volume 4333, Page 3337 (RPRDCT) 20' Utility Easement Volume 2004093, Page 28 (OPRDCT) Fire Lane & Mutual Access Easement Inst. No. 201100305594 (OPRDCT) 26' Fire Lane & Mutual Access Esmt Inst. No. 200900228162 15' Public Water Esmt Inst. No. 200900228162 Ex. 8" Water F i r e L a n e & M u t u a l A c c e s s E a s e m e n t I n s t . N o . 2 0 1 2 0 0 0 5 5 4 9 5 Ro w o f B u s h e s N 65°10'04" W 147.03' N 2 4 ° 4 9 ' 5 6 " E 24 0 . 0 9 ' S 64°44'36" E 147.00' S 2 4 ° 4 9 ' 2 8 " W 23 9 . 0 0 ' Fire Lane & Mutual Access EasementInst. No. 201100305594 (OPRDCT) Ex. 8" Water Legacy Gateway, Ltd. Inst. No. 201300385593 (OPRDCT) Inst. No. 2013-149131 (RPRDCT) Existing Zoning: PD-240R-HC Legacy Gateway, Ltd. Inst. No. 201300385593 (OPRDCT) Inst. No. 2013-149131 (RPRDCT) Existing Zoning: PD-240R-HC ONLY EXIT CONNECT TO EXISTING 8" WATER LINE. PROPOSED 1" IRRIGATION SERVICE INSTALL: 1-1" IRR. TAP AND VALVE 1-IRR. METER & BACKFLOW PREVENTER PROPOSED GAS SERVICE, CONTRACTOR SHALL COORDINATE SERVICE PROVIDER PROPOSED ELECTRICAL SERVICE, PAD MOUNTED TRANSFORMER. CONTRACTOR SHALL COORDINATE WITH SERVICE PROVIDER PROPOSED 2" DOMESTIC SERVICE. CONNECT TO EXISTING 8" WATER LINE INSTALL: 1-8"X2" DOMESTIC TAP AND VALVE 1-1 1/2" (DOM.) WATER METER 1-DOUBLE CHECK BACKLFLOW PREVENTER PROP. COMMUNICATION SERVICE, CONTRACTOR SHALL WITH SERVICE PROVIDER PROP. GREASE TRAP REFER TO PLUMBING PLANS INSTALL: 2-2" 45° BENDS INSTALL: 1-FIRE HYDRANT PER CITY STANDARDS CONNECT TO EXISTING 8" WATER LINE INSTALL: 1-8"X6" TEE 1-8" GATE VALVE 1-6" GATE VALVEPR O P . 1 7 . 3 9 ' P R I V A T E WA T E R L I N E E A S E M E N T PR O P . 1 0 ' PE D E S T R I A N EA S E M E N T 0+ 0 0 1+00 0 + 0 0 EX. FIRE HYDRANT PR O P . 2 6 ' FI R E L A N E AN D M U T U A L AC C E S S EA S E M E N T STA: 0+38.14, GREASE LINE REFER TO PLUMBING PLANS FOR CONTINUATION FL 6": 466.00 (OUT) STA: 1+08.48, SEWER LINE A REFER TO PLUMBING PLANS FOR CONTINUATION FL 6": 466.00 (OUT) 24 LF OF 6" PVC @ 2.13% STA: 0+14.14, GREASE LINE INSTALL: 1-45° BEND FL 6": 465.60 (IN) FL 6": 465.60 (OUT) 14 LF OF 6" PVC @ 1.67% STA: 0+70.34, SEWER LINE A =STA: 0+00, GREASE LINE INSTALL: 1-WYE 1-CLEANOUT FL 6": 465.19 (IN) FL 6": 465.19 (IN) FL 6": 465.19 (OUT) STA: 0+84.48, SEWER LINE A INSTALL: 1-45° BEND FL 6": 465.49 (IN) FL 6": 465.49 (OUT) STA: 0+00, GREASE LINE INSTALL: 1-45° BEND FL 6": 465.36 (IN) FL 6": 465.36 (OUT) 11 LF OF 6" PVC @ 1.67% 70 L F O F 6 " P V C @ 2 . 1 3 % STA: 0+00, SEWER LINE A CONNECT TO EXISTING 8" SEWER. CONTRACTOR SHALL VERIFY EXISTING INVERT PRIOR TO CONSTRUCTION AND CONTACT ENGINEER IF DIFFERENT INSTALL: 1-4' DIA. SEWER MANHOLE FL 6": 463.69 (IN) FFE: 469.25 STA: 0+16.95, SEWER LINE B INSTALL: 1-STUB AND CAP FL: 464.23 17 LF OF 8" PVC @ 0.50% STA: 0+00, SEWER LINE B CONNECT TO EXIST. SEWER MANHOLE EX. FL: 464.14 24 LF OF 6" PVC @ 1.67% 14 LF OF 6" PVC @ 2.13% INSTALL: 1-2" 45° BENDS END PROPOSED 6" FIRE LINE (REFER TO MEP PLANS FOR CONTINUATION) PROPOSED FDC INSTALL: 1-6" 45° BENDS CONNECT TO EXISTING 8" WATER LINE INSTALL: 1-8"X6" TEE 1-8" GATE VALVE 1-6" GATE VALVE 1-DOUBLE CHECK BACK FLOW PREVENTER INSTALL: 2-6" 45° BENDS INSTALL: 1-6" 45° BENDS END PROPOSED 2" DOMESTIC SERVICE (REFER TO MEP PLANS FOR CONTINUATION) SAWCUT REMOVE AND REPLACE EX. PAVEMENT T 0 GRAPHIC SCALE 1 inch = ft. 20 20 40 20 10 DA T E No . RE V I S I O N BY DATE: SHEET File No. 2015-158 CHECKED:CLC DRAWN:JEV DESIGN:JEV CA R L ' S J R SH 1 2 1 & D E N T O N T A P R D CO P P E L L , T X TEXAS REGISTRATION #14199 19 0 3 C E N T R A L D R I V E , S U I T E # 4 0 6 PH O N E : 8 1 7 . 2 8 1 . 0 5 7 2 BE D F O R D , T X 7 6 0 2 1 W W W . C L A Y M O O R E E N G . C O M 08/04/2016 PRELIMINARY CLAYMOORE ENGINEERING PR E L I M I N A R Y U T I L I T Y P L A N UT-1 LEGEND CONSTRUCTION SCHEDULE 1 2 3 4 COMMUNICATION SERVICE CONNECTION: SEE MEP PLANS FOR CONTINUATION OF SERVICE ELECTRIC SERVICE CONNECTION: SEE MEP PLANS FOR CONTINUATION OF SERVICE ELECTRIC SERVICE: CONTACT SERVICE PROVIDER FOR COORDINATION COMMUNICATION SERVICE: CONTACT SERVICE PROVIDER FOR COORDINATION 5 GAS SERVICE: CONTACT SERVICE PROVIDER FOR COORDINATION6 GAS SERVICE CONNECTION: SEE MEP PLANS FOR CONTINUATION OF SERVICE