Preliminary Utility PlanX-Cut
Set X-Cut
Set
Cappe
d
IRF
SSMH
Top=46
7
.
3
4
Fl=464
.
1
4
STATE HIGHWAY NO. 121
(VARIABLE WIDTH RIGHT OF WAY)
Volume 97149, Page 460 (OPRDCT) & cc# 97-R0051944 (RPRDCT)
Lot 5R, Block A
North Gateway Plaza
Inst. No. 201100023079
(OPRDCT)
Existing Zoning: PD-240R-HC
Lot 6,
B
l
o
c
k
A
North
G
a
t
e
w
a
y
P
l
a
z
a
Inst. N
o
.
2
0
1
2
0
0
0
5
5
4
9
5
(OPRD
C
T
)
Exisiti
n
g
Z
o
n
i
n
g
:
R
3
Fire Lane & Mutual Access EasementInst. No. 201200055495
10' Private Water EasementInst. No. 201200055495
15' Pri
v
a
t
e
D
r
a
i
n
a
g
e
E
a
s
e
m
e
n
t
Inst. N
o
.
2
0
1
2
0
0
0
5
5
4
9
5
20' Private Water Easement
Inst. No. 200900228162
10' Pedestrian Access EasementInst. No. 200900228162
20' Electric Esmt
Volume 99036, Page 808 (OPRDCT)
Volume 99054, Page 1401 (OPRDCT)Volume 4300, Page 329 (RPRDCT)Volume 4333, Page 3337 (RPRDCT)
20' Utility Easement
Volume 2004093, Page 28 (OPRDCT)
Fire Lane & Mutual Access Easement
Inst. No. 201100305594 (OPRDCT)
26' Fire Lane & Mutual Access Esmt
Inst. No. 200900228162
15' Public Water Esmt
Inst. No. 200900228162
Ex. 8" Water
F
i
r
e
L
a
n
e
&
M
u
t
u
a
l
A
c
c
e
s
s
E
a
s
e
m
e
n
t
I
n
s
t
.
N
o
.
2
0
1
2
0
0
0
5
5
4
9
5
Ro
w
o
f
B
u
s
h
e
s
N 65°10'04" W 147.03'
N
2
4
°
4
9
'
5
6
"
E
24
0
.
0
9
'
S 64°44'36" E 147.00'
S
2
4
°
4
9
'
2
8
"
W
23
9
.
0
0
'
Fire Lane & Mutual Access EasementInst. No. 201100305594 (OPRDCT)
Ex. 8" Water
Legacy Gateway, Ltd.
Inst. No. 201300385593 (OPRDCT)
Inst. No. 2013-149131 (RPRDCT)
Existing Zoning: PD-240R-HC
Legacy Gateway, Ltd.
Inst. No. 201300385593 (OPRDCT)
Inst. No. 2013-149131 (RPRDCT)
Existing Zoning: PD-240R-HC
ONLY
EXIT
CONNECT TO EXISTING 8" WATER LINE.
PROPOSED 1" IRRIGATION SERVICE
INSTALL:
1-1" IRR. TAP AND VALVE
1-IRR. METER & BACKFLOW PREVENTER
PROPOSED GAS SERVICE,
CONTRACTOR SHALL
COORDINATE SERVICE
PROVIDER
PROPOSED ELECTRICAL SERVICE,
PAD MOUNTED TRANSFORMER.
CONTRACTOR SHALL COORDINATE WITH
SERVICE PROVIDER
PROPOSED 2" DOMESTIC SERVICE.
CONNECT TO EXISTING 8" WATER LINE
INSTALL:
1-8"X2" DOMESTIC TAP AND VALVE
1-1 1/2" (DOM.) WATER METER
1-DOUBLE CHECK BACKLFLOW PREVENTER
PROP. COMMUNICATION SERVICE,
CONTRACTOR SHALL WITH SERVICE
PROVIDER
PROP. GREASE TRAP
REFER TO PLUMBING
PLANS
INSTALL:
2-2" 45° BENDS
INSTALL:
1-FIRE HYDRANT PER CITY STANDARDS
CONNECT TO EXISTING
8" WATER LINE
INSTALL:
1-8"X6" TEE
1-8" GATE VALVE
1-6" GATE VALVEPR
O
P
.
1
7
.
3
9
'
P
R
I
V
A
T
E
WA
T
E
R
L
I
N
E
E
A
S
E
M
E
N
T
PR
O
P
.
1
0
'
PE
D
E
S
T
R
I
A
N
EA
S
E
M
E
N
T
0+
0
0
1+00 0
+
0
0
EX. FIRE HYDRANT
PR
O
P
.
2
6
'
FI
R
E
L
A
N
E
AN
D
M
U
T
U
A
L
AC
C
E
S
S
EA
S
E
M
E
N
T
STA: 0+38.14, GREASE LINE
REFER TO PLUMBING
PLANS FOR CONTINUATION
FL 6": 466.00 (OUT)
STA: 1+08.48, SEWER LINE A
REFER TO PLUMBING
PLANS FOR CONTINUATION
FL 6": 466.00 (OUT)
24 LF OF 6" PVC @ 2.13%
STA: 0+14.14, GREASE LINE
INSTALL:
1-45° BEND
FL 6": 465.60 (IN)
FL 6": 465.60 (OUT)
14 LF OF 6" PVC @ 1.67%
STA: 0+70.34, SEWER LINE A
=STA: 0+00, GREASE LINE
INSTALL:
1-WYE
1-CLEANOUT
FL 6": 465.19 (IN)
FL 6": 465.19 (IN)
FL 6": 465.19 (OUT)
STA: 0+84.48, SEWER LINE A
INSTALL:
1-45° BEND
FL 6": 465.49 (IN)
FL 6": 465.49 (OUT)
STA: 0+00, GREASE LINE
INSTALL:
1-45° BEND
FL 6": 465.36 (IN)
FL 6": 465.36 (OUT)
11 LF OF 6" PVC @ 1.67%
70
L
F
O
F
6
"
P
V
C
@
2
.
1
3
%
STA: 0+00, SEWER LINE A
CONNECT TO EXISTING 8" SEWER.
CONTRACTOR SHALL VERIFY EXISTING
INVERT PRIOR TO CONSTRUCTION AND
CONTACT ENGINEER IF DIFFERENT
INSTALL:
1-4' DIA. SEWER MANHOLE
FL 6": 463.69 (IN)
FFE: 469.25
STA: 0+16.95, SEWER LINE B
INSTALL:
1-STUB AND CAP
FL: 464.23
17 LF OF 8" PVC @ 0.50%
STA: 0+00, SEWER LINE B
CONNECT TO EXIST. SEWER
MANHOLE
EX. FL: 464.14
24 LF OF 6" PVC @ 1.67%
14 LF OF 6" PVC @ 2.13%
INSTALL:
1-2" 45° BENDS
END PROPOSED 6"
FIRE LINE
(REFER TO MEP PLANS
FOR CONTINUATION)
PROPOSED
FDC
INSTALL:
1-6" 45° BENDS
CONNECT TO EXISTING 8"
WATER LINE
INSTALL:
1-8"X6" TEE
1-8" GATE VALVE
1-6" GATE VALVE
1-DOUBLE CHECK BACK
FLOW PREVENTER INSTALL:
2-6" 45° BENDS
INSTALL:
1-6" 45° BENDS
END PROPOSED 2"
DOMESTIC SERVICE
(REFER TO MEP PLANS
FOR CONTINUATION)
SAWCUT REMOVE
AND REPLACE EX.
PAVEMENT
T
0
GRAPHIC SCALE
1 inch = ft.
20 20 40
20
10
DA
T
E
No
.
RE
V
I
S
I
O
N
BY
DATE:
SHEET
File No. 2015-158
CHECKED:CLC
DRAWN:JEV
DESIGN:JEV
CA
R
L
'
S
J
R
SH
1
2
1
&
D
E
N
T
O
N
T
A
P
R
D
CO
P
P
E
L
L
,
T
X
TEXAS REGISTRATION #14199
19
0
3
C
E
N
T
R
A
L
D
R
I
V
E
,
S
U
I
T
E
#
4
0
6
PH
O
N
E
:
8
1
7
.
2
8
1
.
0
5
7
2
BE
D
F
O
R
D
,
T
X
7
6
0
2
1
W
W
W
.
C
L
A
Y
M
O
O
R
E
E
N
G
.
C
O
M
08/04/2016
PRELIMINARY
CLAYMOORE ENGINEERING
PR
E
L
I
M
I
N
A
R
Y
U
T
I
L
I
T
Y
P
L
A
N
UT-1
LEGEND
CONSTRUCTION SCHEDULE
1
2
3
4
COMMUNICATION SERVICE CONNECTION:
SEE MEP PLANS FOR CONTINUATION OF SERVICE
ELECTRIC SERVICE CONNECTION:
SEE MEP PLANS FOR CONTINUATION OF SERVICE
ELECTRIC SERVICE:
CONTACT SERVICE PROVIDER FOR COORDINATION
COMMUNICATION SERVICE:
CONTACT SERVICE PROVIDER FOR COORDINATION
5
GAS SERVICE:
CONTACT SERVICE PROVIDER FOR COORDINATION6
GAS SERVICE CONNECTION:
SEE MEP PLANS FOR CONTINUATION OF SERVICE