SITE17-12-000206_Page_440'-6' OUTTOOUTIDJERIOR INSULATION FlNSHSYSIEM
T.S. _ T -S , 9'-S 9'-S' „ 5.5"
TYP AT EAION
RTHv
49' -8' OUT TO OUT EXTERIOR
�Ilmg
SECTION LOOKING NORTH
TOPOF
DECK BEARIN._G_&
112'-8"
LEVEl01
— l00'-0" v
TOPOF WAL_L_n
^ 118'-1"
100'-0^ 1
SECTION LOOKING WEST
7 8"•t'0
December 7, 2017
CONSTRUCTION NOTES:
GENERAL NOTES:
I. REF ER TO GENERAL SHEET 0001 FOR SHEET INDEX.
aa Rc/�/��j�/�
I BEE
2 REfERTOARCHITECTURALSHEETA-101FOR FLOORPLAN.
°
R���m
3. REFER TO ARCHITECTURAL SHEET A-ID1R FOR REFLECTED
CEILINGPtAN.
d. REFERTOARCHRECTURAL SHS A-102 FOR ROOF PIAN.
5. REFER TD ARCHITECTURAL SHEET M01 FOR DOOR SCHEDULE.
6. REFERTOARCHNECTURAL SHEET A-601 FOR LOWER
ELEVATIONS.
5
7. REFER TO ARCHITECTURAL SHEET AZI FOR ROOM FINISHSCHEDULE.8.
STRUCTURAL FOR ADDITIONAL INFORMATION.
202 CONCRETE SLAB ON METAL DECK. REFER TO
REFER TO OTHER DISCIPLINES FOR ADDITIONALINFORMATION.
Q"-v'r
><
CONSTRUCTION NOTES:
aas
1 EXISTING PAVEMENT.
201 CAST -IN-PLACE CONCRETE MATSLAB. REFER TO
STRUCTURAL FOR ADDITIONAL INFORMATION.
202 CONCRETE SLAB ON METAL DECK. REFER TO
><
STRUCTURAL FOR ADDITIONAL INFORMATION.
-moi
203 B'k8'ki6"CONCRETE MASONRY UNITS. REFERTO
s'fi
B
STRUCTURAL FOR ADDITIONAL INFORMATION.
rGj
a
204 12N 'x16" CONCRETE MASONRY UNITS. REFER TO
41
STRUCTURAL FOR ADDITIONAL INFORMATION.
205 STEELSEAM. REFER TO STRUCTURAL FOR
'S
C
ADDMONALINFORMATION.
w 0
206 FEMA COMPLIANT LOUVER. REFER TO LOUVER
El ON M NIC ft D
-
OR I N.
m �
213 1"SELF-ADHERED EXPANSION JOINT COVER.
ti
EMSEALCOLORSEAL OR APPROVED EQUALCOLOR
-
TO MATCH IFSSYSTEM.
217 STEELCOLUMN. FINISH WITH EXTERIOR GRADE
PAINT.
218 PREMANUFACTUREO COMMERCIAL GRADE
EXTERIOR ALUMINUM ADA ACCESSIBLE RAMP AND
STAIR SYSTEM WITH ACCESSIBLE RAILING AND
j
EDGE PROTECTION.PREMANUFACTURED RAMP
SYSTEM SHALL BE SELF-SUPPORTING. FIELD
ERIFY ISTIN ELEVA DNS.
OR
_ 9 I LL ETA F
g
Gm
REFER TO DOOR SCHEDULE FOR ADDITIONAL
INFORMATION,
¢
F E
221 TUBULAR RAIL lOW PARAPET ACCESS LADDER
WITH PLATFORM AND SECURITY 00 R(NOT
SHOWN). REFERTO DETAILS 1,2,3ON SHEET
a jn
<
ASDL.
222 42"HEIGHT2 RAIL1 t2" O.D. GALVANIZED STEEL
0
GUARDRAIL. REFER TO OETAIL4ON SHEET A501.
w 9w
-
22d CART-W-PLACECONCRETERAMP. REFERTOCIVIL
r
FOR ADDMONAL INFORMATION.
? w8
225 5"(33/4"x43/4") NOMINAL PLAIN RECTANGULAR
U
e
PRE -FINISHED METAL DOWNSPOUT W (TH LEADER.
y
226 3"NOMINAL EXTERIOR INSULATION FINISH SYSTEM.
227 42"STEEL BOLLARD. REFER TO CIVIL FORADDITIONAL
IIt
INf0R V AT1ON.228
WOO 1MNr PRE -CAST CONCRETE SPLASHBLOCK.I229
8"xB"x DEPTH OFWALL PRE -FINISHED METAL
THROUGH WALL SCUPPER. REFER TO DETAIL 16
ON SHEET A502.
N
230 W. 8"x DEPTH Of WALL PRE -FINISHED METAL
THROUGH WALL OVERFLOW SCUPPER. REFERTO
DETAIL 18ONSHEETA502.
231 PRE -FINISHED METAL COLLECTOR BOX.
S
232 t" EXTERIOR INSULATION FINISH SYSTEM
HORIZONTAL REVEAL
w 4
233 1" EXTERIOR INSULATION FINISH SYSTEM VERTICAL
REVEAL
U d
234 PRE -FINISHED METAL PARAPET CAP FLASHING.
p ±
REFERT0 DETAIL30N SHEETA502.
oo O
23525/e' ANlE"S0LID CONCRETE UNIT.
236 HVAC CONDENSING UNIT. REFER TO MECHANICAL
FOR ADDITIONAL INFORMATION.
C
= O w
237 MODIFIEOBITUMEN ROOFINGASSEMBLY.
23824'x24" SUSPENDED ACOUSTICAL PANEL CEILING.
24D CONDENSATE DRAIN LINE. REFER TO MECHANICAL
j ai
FOR ADDITIONAL INFORMATION.
z 6
243 SURFACE MOUNTED EXTERIOR LIGHT FIXTURE.
SHEET
8'
IDENIIFlCAT0N g
A-201
SCALE IN FEET -1/8" =1'-0"