Site Plan.ApprovedPROJECT: SPRINT GOLDEN CLUSTER PROJECT SITE NAME: DA52XC325 SITE CASCADE: DA52XC325 ATC NAME /NO.: IRVING / HACKEERRY / 309143 S ri nt MARKET: DFW SITE ADDRESS: 1850 E. BELTLINE ROAD COPPELL, TX 75019-9007 DALLAS COUNTY SITE TYPE: 100' MONOPOLE SITE INFORMATION AREA MAP PROJECT DESCRIPTION DRAWING INDEX PROPERTY OWNER: SHEET N0: SHEET TITLE REV ENGINEER AMERICAN TOWER CORPORATION REMOVE (E) CLEARWIRE & IDEN ANTENNAS 10 PRESIDENTIAL WAY WOBURN, MA 01801 F,, REMOVE (9) 1-5/8" COAX CABLES T-1 TITLE SHEET & PROJECT DATA C CONTACT: JEN RAEBEL mr REMOVE (1) CLEARWIRE CABINET PHONE: (469) 400-2358 SP -1 SPRINT SPECIFICATIONS C LATITUDE (NAD83): INSTALL (1) NEW ECAB PURCELL SP -2 SPRINT SPECIFICATIONS C GAwg� Bueh 32' 57' 15.0984" N INSTALL (3) NEW PANEL ANTENNAS MODEL# TPA65R-KE6D 32.95419444' Carrollton A-1 SITE PLAN 0 • INSTALL (3) NEW PANEL ANTENNAS MODEL# AIR 6468 B41 BY ERICSSON LONGITUDE (NAD83 pA-IA ENLARGED SITE PLAN 0 Addison o—AS INSTALL (3) NEW RRU31 A-2 ELEVATION 0 -96..9494 186111' INSTALL (3) NEW RRU11-800 96' 30.6996" W appell A-3 ANTENNA LAYOUT & MOUNTING DETAILS 0 je U _ A-4 EQUIPMENT SPECS 0 COUNTY: „r INSTALL (3) 1.7" HYBRID CABLE A -4A EQUIPMENT SPECS 0 DALLAS COUNTY t Farmers _ ZONING JURISDICTION: 11FZ Branch ° RE–USE EXISTING SHELTER A-5 SPECS 0 CITY OF DALLAS e" "oarriuAun E-1 ONE -LINE DIAGRAM AND PLAN 0 Il POWER COMPANY: DFw As E-2 DC POWER & DISTRIBUTION 0 TBD International Airport AAV PROVIDER: "oniinss' G-1 GROUNDING PLAN C TBD G-2 GROUNDING DETAILS C ('__? ACCESS INFORMATION: GD CD N SITE LOCK COMBO: T.B.D LOCATION MAP ARCHITECT/ENGINEER: ALLPRO CONSULTING GROUP, INC. RREPLACE CLWR RAN 9221 LYNDON B. JOHNSON FREEWAY, SUITE 204 DALLAS, TX 75243 CONTACT: CHIYU ZHANG, P.E. RiverehaseGolf Club OFFICE: 972-231-8893 10 FAX: 866-364-8375 '� APPLICABLE CODES N!4 A Elm Fork Narure III ATC PROJECT MANAGER: Preserve 7radEnrrance T ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALL IN ACCORDANCE WITH THE JEN RAEBEL CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING NETWORK DEVELOPMENT PROJECT MANAGER AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. AdministrativeAMERICAN TOWER CORPORATION Approval 8505 FREEPORT PARKWAY, SUITE 425 IRVING, TX 75063 F e Ouvd Sports Complex 1. INTERNATIONAL BUILDING CODE 2012 (972) 999-8915 - OFFICE gSports Garden DFW 2. UNIFORM MECHANICAL CODE 2012 JENNIFER.RAEBEL@AMERICANTOWER.COM 3. UNIFORM PLUMBING CODE 2012 4. NATIONAL ELECTRICAL CODE 2017 E Bek Line Rd SPRINT NOCC: eBehL"�,�, % PHONE: 866-400-6040 Extra space storageEcho PTidel By �uTqL5�J4 / r– �1UP © Sports Garden South 4 Date f 6 Fxe, Clob,I L��i � 3 a F Know what's I]BIOW. Tin N Call before you dig. PLANS PREPARED FOR: Sprint 6580 Sprint Parkway Overland Park, Kansas 66251 PLANS PREPARED BY: 9221LYNDON BJOHNSON FREEWAY SUITE 204, DALLAS, TX 75243 ALLPRO FAX866-364-8375893 ;ONSULTING GROUP, INC. WWW.ALLPROCGI.COM ACGI# 18A676 AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 LICENSE: DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. REVISIONS: DESCRIPTION DATE BY REV ISM FOR RENDS 08/10/18 JE A ISSUED FOR COISIRUCTIDN 09/30/18 RP 0 P._ NAME: TX -DAL ATC NAME/ NO.: IRVING/HACKBERRY, 609143 SITE CASCADE: DA52XC325 SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY SHEET DESCRIPTION: TITLE SHEET SHEET NUMBER: T-1 THESE OUTLINE SPECIFICATIONS IN CONJUNCTION WITH THE SPRINT STANDARD CONSTRUCTION SPECIFICATIONS, INCLUDING CONTRACT DOCUMENTS AND THE CONSTRUCTION DRAWINGS DESCRIBE THE WORK TO BE PERFORMED BY THE CONTRACTOR. SECTION 01 100 - SCOPE OF WORK THE WORK: 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL CORRECTIONS TO ANY WORK IDENTIFIED AS UNACCEPTABLE SHALL COMPLY WITH APPLICABLE NATIONAL CODES AND STANDARDS, LATEST EDITION, AND PORTIONS THEREOF. IN SITE INSPECTION ACTIVITIES AND/OR AS A RESULT OF TESTING. PRECEDENCE: ALLPRO SHOULD CONFLICTS OCCUR BETWEEN THE STANDARD CONSTRUCTION SPECIFICATIONS FOR WIRELESS SITES INCLUDING THE 4. ALL TESTING REQUIRED BY APPLICABLE INSTALLATION MOPS. STANDARD CONSTRUCTION DETAILS FOR WIRELESS SITES AND THE CONSTRUCTION DRAWINGS, INFORMATION ON THE C. REQUIRED CLOSEOUT DOCUMENTATION INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING; CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE. 1. AZIMUTH, DOWNTILT, AGL FROM SUNSIGHT INSTRUMENTS - ANTENNALIGN ALIGNMENT TOOL (AAT) SITE FAMILIARITY: CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS AND 2. SWEEP AND FIBER TESTS DIMENSIONS PRIOR TO PROCEEDING WITH CONSTRUCTION. ON-SITE SUPERVISION: 3. SCANABLE BARCODE PHOTOGRAPHS OF TOWER TOP AND INACCESSIBLE SERIALIZED EQUIPMENT THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 4. ALL AVAILABLE JURISDICTIONAL INFORMATION DRAWINGS, SPECIFICATIONS AND DETAILS REQUIRED AT JOBSITE: THE CONSTRUCTION CONTRACTOR SHALL MAINTAIN A FULL SET OF THE CONSTRUCTION DRAWINGS AT THE JOBSITE FROM 5. PDF SCAN OF REDLINES PRODUCED IN FIELD MOBILIZATION THROUGH CONSTRUCTION COMPLETION. A. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONING SYSTEM. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. B. CONTRACTOR SHALL NOTIFY SPRINT CONSTRUCTION MANAGER OF ANY VARIATIONS PRIOR TO PROCEEDING WITH THE WORK.DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS NOTED OTHERWISE. MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. C. MARK THE FIELD SET OF DRAWINGS IN RED, DOCUMENTING ANY CHANGES FROM THE CONSTRUCTION DOCUMENTS. METHODS OF PROCEDURE (MOPS) FOR CONSTRUCTION: CONTRACTOR SHALL PERFORM WORK AS DESCRIBED IN THE FOLLOWING INSTALLATION AND COMMISSIONING MOPS. A. INSTALLATION OF RRU'S B. CABLING C. TS -0200 REV 4 - ANTENNA UNE ACCEPTANCE STANDARDS D. SPRINT CELL SITE ENGINEERING NOTICE - EN 2012-001, REV 1. E. COMMISSIONING MOPS SECTION 01 200 - COMPANY FURNISHED MATERIAL AND EQUIPMENT COMPANY FURNISHED MATERIAL AND EQUIPMENT IS IDENTIFIED ON THE RF DATA SHEET IN THE CONSTRUCTION DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR SPRINT PROVIDED MATERIAL AND EQUIPMENT TO ENSURE IT IS PROTECTED AND HANDLED PROPERLY THROUGHOUT THE CONSTRUCTION DURATION. CONTRACTOR RESPONSIBLE FOR RECEIPT OF SPRINT FURNISHED EQUIPMENT AT CELL SITE OR CONTRACTORS LOCATION. CONTRACTOR TO COMPLETE SHIPPING AND RECEIPT DOCUMENTATION IN ACCORDANCE WITH COMPANY PRACTICE. SECTION 01 300 - CELL SITE CONSTRUCTION CO. NOTICE TO PROCEED: NO WORK SHALL COMMENCE PRIOR TO COMPANY'S WRITTEN NOTICE TO PROCEED AND THE ISSUANCE OF WORK ORDER. SITE CLEANLINESS: CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH. AT THE COMPLETION OF THE WORK, CONTRACTOR SHALL REMOVE FROM THE SITE ALL REMAINING RUBBISH, IMPLEMENTS, TEMPORARY FACILITIES, AND SURPLUS MATERIALS. SECTION 01 400 - SUBMITTALS & TESTS ALTERNATES: AT THE COMPANY'S REQUEST, ANY ALTERNATIVES TO THE MATERIALS OR METHODS SPECIFIED SHALL BE SUBMITTED TO SPRINTS CONSTRUCTION MANAGER FOR APPROVAL. SPRINT WILL REVIEW AND APPROVE ONLY THOSE REQUESTS MADE IN WRITING. NO VERBAL APPROVALS WILL BE CONSIDERED, TESTS AND INSPECTIONS: A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION TESTS, INSPECTIONS AND PROJECT DOCUMENTATION. B. CONTRACTOR SHALL ACCOMPLISH TESTING INCLUDING BUT NOT LIMITED TO THE FOLLOWING: 1. COAX SWEEPS AND FIBER TESTS PER TS -0200 REV 4 ANTENNA LINE ACCEPTANCE STANDARDS. 2. AGL, AZIMUTH AND DOWNTILT PROVIDE AN AUTOMATED REPORT UPLOADED TO SITERRA USING A COMMERCIAL MADE -FOR THE PURPOSE ELECTRONIC ANTENNA ALIGNMENT TOOL (AAT). INSTALLED AZIMUTH, CENTERLINE AND DOWNTILT MUST CONFORM WITH RF CONFIGURATION DATA 6. A PDF SCAN OF REDLINE MARK-UPS SUITABLE FOR USE IN ELECTRONIC AS -BUILT DRAWING PRODUCTION 7. LIEN WAIVERS 8. FINAL PAYMENT APPLICATION 9. REQUIRED FINAL CONSTRUCTION PHOTOS 10. CONSTRUCTION AND COMMISSIONING CHECKLIST COMPLETE WITH NO DEFICIENT ITEMS 11. ALL POST NTP TASKS INCLUDING DOCUMENT UPLOADS COMPLETED IN SITERRA (SPRINTS DOCUMENT REPOSITORY OF RECORD). 12. CLOSEOUT PHOTOGRAPHS: a PROVIDE PHOTOGRAPHS OF FINAL PROJECT PER THE FOLLOWING LIST. ADDITIONAL PHOTOGRAPHS MAY BE REQUIRED TO SUPPORT ACCEPTANCE PROCESSES (i) BACK MAIN HYBRID CABLE ROUTE (MINIMUM TWO PHOTOS) (ii) OF EACH ANTENNA AND RRH (iii) MANUFACTURERS NAME TAG FOR ALL SERIAUZED EQUIPMENT (iv) PULL AND DISTRIBUTION BOXES INTERMEDIATE BETWEEN RRH'S AND MMBS (DOOR OPEN) (vii) BREAK OUT CYLINDERS (viii) ASR SIGNAGE FOR SPRINT OWNED TOWERS (ix) RADIATION EXPOSURE WARNING SIGNS (x) PHOTOGRAPH FROM EACH SECTOR FROM APPROXIMATELY RAD CENTER OF ANY NEW ANTENNA AT HORIZON. b LOAD PHOTOS TO SITERRA PROJECT LIBRARY 15. IN 15 CREATE NEW CATEGORY; 2.5 DEPLOYMENT, AND SECTION; PERMANENT CONSTRUCTION. LABEL PHOTOS WITH SITE CASCADE AND VIEW BEING DEPICTED. CAMERAS USED TO TAKE PHOTOGRAPHS SHALL GPS ENABLED SUCH THAT THE GPS COORDINATES ARE INCLUDED IN THE PHOTO MEDIA -FILE INFORMATION. COMMISSIONING: PERFORM ALL COMMISSIONING AS REQUIRED BY APPLICABLE MOPS INTEGRATION: PERFORM ALL INTEGRATION ACTIVITIES AS REQUIRED BY APPLICABLE MOPS SECTION 09 900 - PAINTING QUALITY ASSURANCE: A. COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE PRODUCTS OF ACCEPTABLE MANUFACTURERS WHICH HAVE BEEN IN SATISFACTORY USE IN SIMILAR SERVICE FOR THREE YEARS. USE EXPERIENCED INSTALLERS. DELIVER, HANDLE, AND STORE MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. B. COMPLY WITH ALL ENVIRONMENTAL REGULATIONS FOR VOLATILE ORGANIC COMPOUNDS. MATERIALS: A. MANUFACTURERS: BENJAMIN MOORE, ICI DEVOE COATINGS, PPG, SHERWN WILLIAMS OR APPROVED EQUAL. PROVIDE PREMIUM GRADE, PROFESSIONAL -QUALITY PRODUCTS FOR COATING SYSTEMS PAINT SCHEDULE: A. EXTERIOR ANTENNAE AND ANTENNA MOUNTING HARDWARE: ONE COAT OF PRIMER AND TWO FINISH COATS. PAINT FOR ANTENNAE SHALL BE NON-METALLIC BASED AND CONTAIN NO METALUC PARTICLES. PROVIDE COLORS AND PATTERNS AS REQUIRED TO MASK APPEARANCE OF ANTENNAE ON ADJACENT BUILDING SURFACES AND AS ACCEPTABLE TO THE OWNER. REFER TO ANTENNA MANUFACTURER'S INSTRUCTIONS WHENEVER POSSIBLE. B. WATER TANKS: TOUCH UP - PREPARE SURFACES TO BE REPAIRED. FOLLOW INDUSTRY STANDARDS AND REQUIREMENTS OF OWNER TO MATCH EXISTING COATING AND FINISH. PAINTING APPLICATION: 1. INSPECT SURFACES, REPORT UNSATISFACTORY CONDITIONS IN WRITING; BEGINNING WORK MEANS ACCEPTANCE OF SUBSTRATE. 2. COMPLY WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS FOR PREPARATION, PRIMING AND COATING WORK. COORDINATE WITH WORK OF OTHER SECTIONS. 3. MATCH APPROVED MOCK-UPS FOR COLOR, TEXTURE, AND PATTERN. RE -COAT OR REMOVE AND REPLACE WORK WHICH DOES NOT MATCH OR SHOWS LOSS OF ADHESION. 4. CLEAN UP, TOUCH UP AND PROTECT WORK. TOUCHUP PAINTING: 1. GALVANIZING DAMAGE AND ALL BOLTS AND NUTS SHALL BE TOUCHED UP AFTER TOWER ERECTION WITH "GALVANOX," "DRY GALV," OR "ZINC -IT." 2. FIELD TOUCHUP PAINT SHALL BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. ALL METAL COMPONENTS SHALL BE HANDLED WITH CARE TO PREVENT DAMAGE TO THE COMPONENTS, THEIR PRESERVATIVE TREATMENT, OR THEIR PROTECTIVE COATINGS. SECTION 11 700 - ANTENNA ASSEMBLY. REMOTE RADIO HEADS AND CABLE INSTALLATION SUMMARY: THIS SECTION SPECIFIES INSTALLATION OF ANTENNAS, RRH'S, AND CABLE EQUIPMENT, INSTALLATION, AND TESTING OF COAXIAL FIBER CABLE. ANTENNAS AND RRH'S: THE NUMBER AND TYPE OF ANTENNAS AND RRH'S TO BE INSTALLED IS DETAILED ON THE CONSTRUCTION DRAWINGS. HYBRID CABLE: HYBRID CABLE WILL BE DC/FIBER AND FURNISHED FOR INSTALLATION AT EACH SITE. CABLE SHALL BE INSTALLED PER THE CONSTRUCTION DRAWINGS AND THE APPLICABLE MANUFACTURER'S REQUIREMENTS. JUMPERS AND CONNECTORS: FURNISH AND INSTALL 1/2" COAX JUMPER CABLES BETWEEN THE RRH'S AND ANTENNAS. JUMPERS SHALL BE TYPE LDF 4, FLC 12-50, CR 540, OR FXL 540. SUPER -FLEX CABLES ARE NOT ACCEPTABLE. JUMPERS BETWEEN THE RRH'S AND ANTENNAS OR TOWER TOP AMPLIFIERS SHALL CONSIST OF 1/2 INCH FOAM DIELECTRIC, OUTDOOR RATED COAXIAL CABLE, MIN LENGTH FOR JUMPER SHALL BE 10"-0". REMOTE ELECTRICAL TILT (RET) CABLES: MISCELLANEOUS: INSTALL SPLITTERS, COMBINERS, FILTERS PER RF DATA SHEET, FURNISHED BY SPRINT. ANTENNA INSTALLATION: THE CONTRACTOR SHALL ASSEMBLE ALL ANTENNAS ONSITE IN ACCORDANCE WITH THE INSTRUCTIONS SUPPLIED BY THE MANUFACTURER. ANTENNA HEIGHT, AZIMUTH, AND FEED ORIENTATION INFORMATION SHALL BE A DESIGNATED ON THE CONSTRUCTION DRAWINGS. A. THE CONTRACTOR SHALL POSITION THE ANTENNA ON TOWER PIPE MOUNTS SO THAT THE BOTTOM STRUT IS LEVEL. THE PIPE MOUNTS SHALL BE PLUMB TO WITHIN 1 DEGREE. B. ANTENNA MOUNTING REQUIREMENTS: PROVIDE ANTENNA MOUNTING HARDWARE AS INDICATED ON THE DRAWINGS. HYBRID CABLES INSTALLATION: A. THE CONTRACTOR SHALL ROUTE, TEST, AND INSTALL ALL CABLES AS INDICATED ON THE CONSTRUCTION DRAWINGS AND IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. B. THE INSTALLED RADIUS OF THE CABLES SHALL NOT BE LESS THAN THE MANUFACTURER'S SPECIFICATIONS FOR BENDING RADII. C. EXTREME CARE SHALL BE TAKEN TO AVOID DAMAGE TO THE CABLES DURING HANDLING AND INSTALLATION. 1. FASTENING MAIN HYBRID CABLES: ALL CABLES SHALL BE PERMANENTLY FASTENED TO THE COAX LADDER AT 4'-0" OC USING NON-MAGNETIC STAINLESS STEEL CLIPS. 2. FASTENING INDIVIDUAL FIBER AND DC CABLES ABOVE BREAKOUT ENCLOSURE (MEDUSA), WITHIN THE MMBS CABINET AND ANY INTERMEDIATE DISTRIBUTION BOXES: a. FIBER: SUPPORT FIBER BUNDLES USING M" VELCRO STRAPS OF THE REQUIRED LENGTH @ 18" OC. STRAPS SHALL BE UV, OIL AND WATER RESISTANT AND SUITABLE FOR INDUSTRIAL INSTALLATIONS AS MANUFACTURED BY TEXTOL OR APPROVED EQUAL. b. DC: SUPPORT DC BUNDLES WITH ZIP TIES OF THE ADEQUATE LENGTH. ZIP TIES TO BE UV STABILIZED, BLACK NYLON, WITH TENSILE STRENGTH AT 12,000 PSI AS MANUFACTURED BY NELCO PRODUCTS OR EQUAL. 3. FASTENING JUMPERS: SECURE JUMPERS TO THE SIDE ARMS OR HEAD FRAMES USING STAINLESS STEEL TIE WRAPS OR STAINLESS STEEL BUTTERFLY CLIPS. 4. CABLE INSTALLATION: a. INSPECT CABLE PRIOR TO USE FOR SHIPPING DAMAGE, NOTIFY THE CONSTRUCTION MANAGER. b. CABLE ROUTING: CABLE INSTALLATION SHALL BE PLANNED TO ENSURE THAT THE LINES WILL BE PROPERLY ROUTED IN THE CABLE ENVELOP AS INDICATED ON THE DRAWINGS. AVOID TWISTING AND CROSSOVERS. C. HOIST CABLE USING PROPER HOISTING GRIPS. DO NOT EXCEED MANUFACTURES RECOMMENDED MAXIMUM BEND RADIUS. PLANS PREPARED FOR: Sprint 6580 Sprint Parkway Overland Park, Kansas 66251 PLANS PREPARED BY: 9221LYNDON BJOHNSON FREEWAY SUITE 204, DALLAS, TX 75243 ALLPRO FAX866-3648375893 ,ONSULTING GROUP, INC. WWW.ALLPROCGLCOM ACGI# 18A676 AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 LICENSE: 8/30/18 DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. REVISIONS: DESCRIPTION DATE BY REV ISSUED FOR RENEW 08/10/16 ,E A ISSUED FOR CONSTRUCTION 06/30/18 RP 0 SITE NAME: TX -DAL ATC NAME/ NO.: IRVING/HACKBERRY, 609143 SITE CASCADE: DA52XC325 SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY SHEET DESCRIPTION: SPRINT SPECIFICATIONS SHEET NUMBER: SP -1 CONTINUE FROM SP -1 5. GROUNDING OF TRANSMISSION LINES: ALL TRANSMISSION LINES SHALL BE GROUNDED AS INDICATED ON DRAWINGS 6. HYBRID CABLE COLOR CODING: ALL COLOR CODING SHALL BE AS REQUIRED IN TS 0200 REV 4. 7. HYBRID CABLE LABELING: INDIVIDUAL HYBRID AND DC BUNDLES SHALL BE LABELED ALPHA -NUMERICALLY ACCORDING TO SPRINT CELL SITE ENGINEERING NOTICE - EN 2012-001, REV 1 RF AND CAL JUMPERS THE CDS NEED TO PROPERLY REFLECT THE SPRINT REQUIREMENTS FOR PROPER SUPPORT WITHIN 18 INCHES OF THE BOTTOM OF THE RRU AND ANTENNA CONNECTORS. THE SUPPORT IS ABSOLUTELY NECESSARY TO PREVENT CONNECTOR FAILURES AND PIM ISSUES. THE RF AND CAL JUMPERS MUST EXTEND 1870 24 INCHES STRAIGHT BELOW THE CONNECTORS TO PREVENT STRESS ON THE CONNECTORS, AVOID PIM ISSUES, ALLOW PROPER WEATHERPROOFING, AND FUTURE RRU AND ANTENNA MAINTENANCE. THIS IS WHY WE RECOMMENDED 8' MINIMUM MAST PIPES. DC CABUNG DC CABUNG TO THE RRUS MUST BE PROPERLY SECURED TO THE RRU CABLE TIE PLATE USING EITHER VELCRO OR A ZIP TIE TO PREVENT STRESS ON THE CONNECTION TO THE RRU. A DRIP LOOP SHOULD ALSO BE INSTALLED BELOW THE RRU CONNECTION TO AVOID STRESS ON THE CONNECTION. FIBER JUMPER MANAGEMENT FIBER JUMPERS SHOULD NOT BE COILED UP IMMEDIATELY BELOW THE RRU. DOING SO CREATES CLUTTER BELOW THE RRU AND WILL CREATE ISSUES DURING MAINTENANCE ACTIVITIES. FIBER JUMPER SLACK LOOPS MUST EXCEED 7" MINIMUM ID. FIBER JUMPER SLACK LOOPS MUST BE PROPERLY SECURED AT AT LEAST TWO LOCATIONS TO PREVENT DAMAGE TO THE JUMPERS. FIBER CONNECTIONS, EVEN NEW FIBERS, MUST BE CLEANED USING AN SPRINT APPROVED METHOD PRIOR TO CONNECTION TO ANY EQUIPMENT. FIBER BREAKOUT CYLINDERS MUST BE SECURED AT TWO LOCATIONS, AND THE CABLES LEEDING INTO AND OUT OF THE CYLINDERS MUST BE SECURED TO A STABLE STRUCTURAL ELEMENT WITHIN 18 INCHES TO PREVENT STRESS ON THE CONNECTIONS INTO THE CYUNDERS. FIBER JUMPERS MUST NOT BE SUBJECTED TO ANY STRESSES DURING OR AFTER INSTALLATION. USE ADEQUATE SLACK IN FIBER JUMPERS TRUNK AND HYBRID CABLES TO AVOID BEND RADIUS ISSUES. RET CABLING RET CABLING TO THE RRU AND ANTENNA MUST BE PROPERLY SUPPORTED AND SECURED SIMILARLY TO THE RF AND CAL JUMPERS. SLACK LOOPS MUST BE MANAGED AND SECURED SIMILARLY TO FIBER CABLES. WEATHERPROOFING EXTERIOR CONNECTORS AND HYBRID CABLE GROUND KITS: A. ALL FIBER & COAX CONNECTORS AND GROUND KITS SHALL BE WEATHERPROOFED. B. WEATHERPROOFED USING ONE OF THE FOLLOWING METHODS. ALL INSTALLATIONS MUST BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY BEST PRACTICES. 1. COLD SHRINK: ENCOMPASS CONNECTOR IN COLD SHRINK TUBING AND PROVIDE A DOUBLE WRAP OF 2" ELECTRICAL TAPE EXTENDING 2° BEYOND TUBING. PROVIDE 3M COLD SHRINK CXS SERIES OR EQUAL. 2. SELF -AMALGAMATING TAPE: CLEAN SURFACES. APPLY A DOUBLE WRAP OF SELF -AMALGAMATING TAPE 2" BEYOND CONNECTOR. APPLY A SECOND WRAP OF SELF -AMALGAMATING TAPE IN OPPOSITE DIRECTION. APPLY DOUBLE WRAP OF 2" WIDE ELECTRICAL TAPE EXTENDING 2" BEYOND THE SELF -AMALGAMATING TAPE. 3. 3M SLIM LOCK CLOSURE 716: SUBSTITUTIONS WILL NOT BE ALLOWED. 4. AMPHENOL JUMPER SITH MINI DIN MALE CONNECTORS/BOOTS ATTACHED. 5. OPEN FLAME ON JOB SITE IS NOT ACCEPTABLE DC CIRCUIT BREAKER LABELING A. NEW DC CIRCUIT IS REQUIRED IN MMES CABINET SHALL BE CLEARLY IDENTIFIED AS TO RRU BEING SERVICED SECTION 26 100 - BASIC ELECTRICAL REQUIREMENTS SUMMARY: THIS SECTION SPECIFIES BASIC ELECTRICAL REQUIREMENTS FOR SYSTEMS AND COMPONENTS. QUALITY ASSURANCE: A. ALL EQUIPMENT FURNISHED UNDER DIVISION 26 SHALL CARRY UL LABELS AND USTINGS WHERE SUCH LABELS AND LISTINGS ARE AVAILABLE IN THE INDUSTRY. B. MANUFACTURERS OF EQUIPMENT SHALL HAVE A MINIMUM OF THREE YEARS EXPERIENCE WdTH THEIR EQUIPMENT INSTALLED AND OPERATING IN THE FIELD IN A USE SIMILAR TO THE PROPOSED USE FOR THIS PROJECT. C. MATERIALS AND EQUIPMENT: ALL MATERIALS AND EQUIPMENT SPECIFIED IN DIVISION 26 OF THE SAME TYPE SHALL BE OF THE SAME MANUFACTURER AND SHALL BE NEW, OF THE BEST QUALITY AND DESIGN, AND FREE FROM DEFECTS SUPPORTING DEVICES: A. ALL EQUIPMENT FURNISHED UNDER DIVISION 26 SHALL CARRY UL LABELS AND USTINGS WHERE SUCH LABELS AND LISTINGS ARE AVAILABLE IN THE INDUSTRY. B. MANUFACTURERS OF EQUIPMENT SHALL HAVE A MINIMUM OF THREE YEARS EXPERIENCE WITH THEIR EQUIPMENT INSTALLED AND OPERATING IN THE FIELD IN A USE SIMILAR TO THE PROPOSED USE FOR THIS PROJECT. C. MATERIALS AND EQUIPMENT: ALL MATERIALS AND EQUIPMENT SPECIFIED IN DIVISION 26 OF THE SAME TYPE SHALL BE OF THE SAME MANUFACTURER AND SHALL BE NEW, OF THE BEST QUALITY AND DESIGN, AND FREE FROM DEFECTS SUPPORTING DEVICES: A. MANUFACTURED STRUCTURAL SUPPORT MATERIALS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY THE FOLLOWING: 1. ALLIED TUBE AND CONDUIT 2. B -LINE SYSTEM 3. UNISTRUT DIVERSIFIED PRODUCTS 4. THOMAS & BETTS B. FASTENERS: TYPES, MATERIALS, AND CONSTRUCTION FEATURES AS FOLLOWS: 1. EXPANSION ANCHORS: CARBON STEEL WEDGE OR SLEEVE TYPE. 2. POWER -DRIVEN THREADED STUDS: HEAT-TREATED STEEL, DESIGNED SPECIFICALLY FOR THE INTENDED SERVICE. 3. FASTEN BY MEANS OF WOOD SCREWS ON WOOD. 4. TOGGLE BOLTS ON HOLLOW MASONRY UNITS. 5. CONCRETE INSERTS OR EXPANSION BOLTS ON CONCRETE OR SOUD MASONRY. 6. MACHINE SCREWS, WELDED THREADED STUDS, OR SPRING -TENSION CLAMPS ON STEEL. 7. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE SHALL NOT BE PERMITTED. 8. DO NOT WELD CONDUIT, PIPE STRAPS, OR ITEMS OTHER THAN THREADED STUDS TO STEEL STRUCTURES. 9. IN PARTITIONS OF LIGHT STEEL CONSTRUCTION, USE SHEET METAL SCREWS. SUPPORTING DEVICES: A. INSTALL SUPPORTING DEVICES TO FASTEN ELECTRICAL COMPONENTS SECURELY AND PERMANENTLY IN ACCORDANCE WJITH NEC. B. COORDINATE 'NTH THE BUILDING STRUCTURAL SYSTEM AND WITH OTHER TRADES. C. UNLESS OTHERWISE INDICATED ON THE DRAWINGS, FASTEN ELECTRICAL ITEMS AND THEIR SUPPORTING HARDWARE SECURELY TO THE STRUCTURE IN ACCORDANCE WITH THE FOLLOWING: D. ENSURE THAT THE LOAD APPLIED BY ANY FASTENER DOES NOT EXCEED 25 PERCENT OF THE PROOF TEST LOAD. E. USE VIBRATION AND SHOCK -RESISTANT FASTENERS FOR ATTACHMENTS TO CONCRETE SLABS. ELECTRICAL IDENTIFICATION: A. UPDATE AND PROVIDE TYPED CIRCUIT BREAKER SCHEDULES IN THE MOUNTING BRACKET, INSIDE DOORS OF AC PANEL BOARDS NTH ANY CHANGES MADE TO THE AC SYSTEM. B. BRANCH CIRCUITS FEEDING AVIATION OBSTRUCTION LIGHTING EQUIPMENT SHALL BE CLEARLY IDENTIFIED AS SUCH AT THE BRANCH CIRCUIT PANEL BOARD. SECTION 26 200 - ELECTRICAL MATERIALS AND EQUIPMENT CONDUIT: A. RIGID GALVANIZED STEEL (RGS) CONDUIT SHALL BE USED FOR EXTERIOR LOCATIONS ABOVE GROUND AND IN UNFINISHED INTERIOR LOCATIONS AND FOR ENCASED RUNS IN CONCRETE. RIGID CONDUIT AND FITTINGS SHALL BE STEEL, COATED WITH ZINC EXTERIOR AND INTERIOR BY THE HOT DIP GALVANIZING PROCESS. CONDUIT SHALL BE PRODUCED TO ANSI SPECIFICATIONS C80.1, FEDERAL SPECIFICATION WW -C-581 AND SHALL BE LISTED WITH THE UNDERWRITERS' LABORATORIES. FITTINGS SHALL BE THREADED - SET SCREW OR COMPRESSION FITTINGS WILL NOT BE ACCEPTABLE. RGS CONDUITS SHALL BE MANUFACTURED BY ALLIED, REPUBLIC OR WHEATLAND. B. UNDERGROUND CONDUIT AND CONDUIT IN CONCRETE SHALL BE POLYVINYLCHLORIDE (PVC) SUITABLE FOR DIRECT BURIAL AS APPLICABLE. JOINTS SHALL BE BELLED, AND FLUSH SOLVENT WELDED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. CONDUIT SHALL BE CARLON ELECTRICAL PRODUCTS OR APPROVED EQUAL C. TRANSITIONS BETWEEN PVC AND RIGID (RGS) SHALL BE MADE WITH PVC COATED METALLIC LONG SWEEP RADIUS ELBOWS. D. EMT OR RIGID GALVANIZED STEEL CONDUIT MAY BE USED IN FINISHED SPACES CONCEALED IN WALLS AND CEILINGS. EMT SHALL BE MILD STEEL, ELECTRICALLY WELDED, ELECTRO -GALVANIZED OR HOT -DIPPED GALVANIZED AND PRODUCED TO ANSI SPECIFICATION C80.3, FEDERAL SPECIFICATION WW -C-563, AND SHALL BE UL LISTED. EMT SHALL BE MANUFACTURED BY ALLIED, REPUBLIC OR WHEATLAND, OR APPROVED EQUAL FITTINGS SHALL BE METALLIC COMPRESSION. SET SCREW CONNECTIONS SHALL NOT BE ACCEPTABLE. E. LIQUID TIGHT FLEXIBLE METALLIC CONDUIT SHALL BE USED FOR FINAL CONNECTION TO EQUIPMENT. FITTINGS SHALL BE METALLIC GLAND TYPE COMPRESSION FITTINGS, MAINTAINING THE INTEGRITY OF CONDUIT SYSTEM. SET SCREW CONNECTIONS SHALL NOT BE ACCEPTABLE. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL NOT EXCEED 6 -FEET. LFMC SHALL BE PROTECTED AND SUPPORTED AS REQUIRE BY NEC. MANUFACTURERS OF FLEXIBLE CONDUITS SHALL BE CAROL, ANACONDA METAL HOSE OR UNIVERSAL METAL HOSE, OR APPROVED EQUAL. F. MINIMUM SIZE CONDUIT SHALL BE 3/4 INCH (21MM). HUBS AND BOXES: A. AT ENTRANCES TO CABINETS OR OTHER EQUIPMENT NOT HAVING INTEGRAL THREADED HUBS PROVIDE METALLIC THREADED HUBS OF THE SIZE AND CONFIGURATION REQUIRED. HUB SHALL INCLUDE LOCKNUT AND NEOPRENE 0 -RING SEAL. PROVIDE IMPACT RESISTANT 105 DEGREE C PLASTIC BUSHINGS TO PROTECT CABLE INSULATION. B. CABLE TERMINATION FITTINGS FOR CONDUIT 1. CABLE TERMINATORS FOR RGS CONDUITS SHALL BE TYPE CRC BY O-Z/GEDNEY OR EQUAL BY ROX TEC. 2. CABLE TERMINATORS FOR LFMC SHALL BE ETCO - CL2075; OR MADE FOR THE PURPOSE PRODUCTS BY ROXTEC. C. EXTERIOR PULL BOXES AND PULL BOXES IN INTERIOR INDUSTRIAL AREAS SHALL BE PLATED CAST ALLOY, HEAVY DUTY, WEATHERPROOF, DUST PROOF, WITH GASKET, PLATED IRON ALLOY COVER AND STAINLESS STEEL COVER SCREWS, CROUSE -HINDS WAB SERIES OR EQUAL. D. CONDUIT OUTLET BODIES SHALL BE PLATED CAST ALLOY WITH SIMILAR GASKETED COVERS. OUTLET BODIES SHALL BE OF THE CONFIGURATION AND SIZE SUITABLE FOR THE APPLICATION. PROVIDE CROUSE -HINDS FORM 8 OR EQUAL. E. MANUFACTURER FOR BOXES AND COVERS SHALL BE HOFFMAN, SQUARE "D°, CROUSE -HINDS, COOPER, ADALET, APPLETON, 0-Z GEDNEY, RACO, OR APPROVED EQUAL. SUPPLEMENTAL GROUNDING SYSTEM A. FURNISH AND INSTALL A SUPPLEMENTAL GROUNDING SYSTEM TO THE EXTENT INDICATED ON THE DRAWINGS. SUPPORT SYSTEM WITH NON-MAGNETIC STAINLESS STEEL CUPS WITH RUBBER GROMMETS. GROUNDING CONNECTORS SHALL BE TINNED COPPER WIRE, SIZES AS INDICATED ON THE DRAWINGS. PROVIDE STRANDED OR SOLD BARE OR INSULATED CONDUCTORS EXCEPTED AS OTHERWISE NOTED. B. SUPPLEMENTAL GROUNDING SYSTEM: ALL CONNECTIONS TO BE MADE WITH CAD WELDS, EXCEPT AT EQUIPMENT USE LUGS OR OTHER AVAILABLE GROUNDING MEANS AS REQUIRED BY MANUFACTURER; AT GROUND BARS USE TWO HOLE SPADES WITH NO OX. C. STOLEN GROUND -BARS: IN THE EVENT OF STOLEN GROUND BARS, CONTACT SPRINT CM FOR REPLACEMENT INSTRUCTION USING THREADED ROD KITS. EXISTING STRUCTURE: A. EXISTING EXPOSED WIRING AND ALL EXPOSED OUTLETS, RECEPTACLES, SWITCHES, DEVICES, BOXES, AND OTHER EQUIPMENT THAT ARE NOT TO BE UTIUZED IN THE COMPLETED PROJECT SHALL BE REMOVED OR DE -ENERGIZED AND CAPPED IN THE WALL, CEILING, OR FLOOR SO THAT THEY ARE CONCEALED AND SAFE. WALL, CEILING, OR FLOOR SHALL BE PATCHED TO MATCH THE ADJACENT CONSTRUCTION. CONDUIT AND CONDUCTOR INSTALLATION: A. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEIUNG LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. B. CONDUCTORS SHALL BE PULLED IN ACCORDANCE NTH ACCEPTED GOOD PRACTICE. PLANS PREPARED FOR: Sprint 6580 Sprint Parkway Overland Park, Kansas 66251 PLANS PREPARED BY: AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 LICENSE: 8/30/18 DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. REVISIONS: DESCRIPTION DATE BY REV ISSUED RIR RENEW 08/10/18 JE A ISSUED FOR CONSIRUCTION 08/30/18 RP 0 SITE NAME: TX -DAL ATC NAME/ NO.: IRVING/HACKBERRY, 609143 SITE CASCADE: DA52XC325 SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY SHEET DESCRIPTION: SPRINT SPECIFICATIONS SHEET NUMBER: SP -2 9221LYNDON BJOHNSON FREEWAY ftftnoo SUITE 204, DALLAS, TX 75243 L L P R 0 FAX: 866-364375972-231-8893 AX866-3648375893 LILTING GROUP, INC. WWW.ALLPROCGI.COM ACGI# 18A676 AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 LICENSE: 8/30/18 DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. REVISIONS: DESCRIPTION DATE BY REV ISSUED RIR RENEW 08/10/18 JE A ISSUED FOR CONSIRUCTION 08/30/18 RP 0 SITE NAME: TX -DAL ATC NAME/ NO.: IRVING/HACKBERRY, 609143 SITE CASCADE: DA52XC325 SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY SHEET DESCRIPTION: SPRINT SPECIFICATIONS SHEET NUMBER: SP -2 PLANS PREPARED FOR: Sprint 'JP 6580 Sprint Parkway Overland Park, Kansas 66251 PLANS PREPARED BY: 9221LYNDON BJOHNSON FREEWAY SUITE 204, DALLAS, TX 75243 L L P R 0 FAX: 866-364375972-231-8893 AX866-3648375893 ,ONSULTING GROUP, INC. WWW.ALLPROCGI.COM ACGI# 18A676 AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 LICENSE: 8/30/18 -DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. -REVISIONS: DESCRIPTION DATE BY REV ISSUED RIR RENEW 08/10/18 ,E A ISSUED FOR Cpi MCTION 08/30/18 RP 0 — SITE NAME: TX -DAL - ATC NAME/ NO.: IRVING/HACKBERRY, 609143 SITE CASCADE: DA52XC325 - SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY - SHEET DESCRIPTION: SITE PLAN SHEET NUMBER: A-1 PLANS PREPARED FOR: Sprint 'JP 6580 Sprint Parkway Overland Park, Kansas 66251 PLANS PREPARED BY: 9221LYNDON BJOHNSON FREEWAY SUITE 204, DALLAS, TX 75243 L L P R 0 FAX: 866-360375972-231-8893 AX866-3648375893 ,ONSULTING GROUP, INC. WWW.ALLPROCGI.COM ACGI# 18A676 AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 LICENSE: 8/30/18 -DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. -REVISIONS: DESCRIPTION DATE BY REV ISSUED RIR RENEW 08/10/18 ,E A ISSUED FOR CONSIRIICTION 08/30/18 RP 0 SITE NAME: TX -DAL - ATC NAME/ NO.: IRVING/HACKBERRY, 609143 SITE CASCADE: DA52XC325 - SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY - SHEET DESCRIPTION: ENLARGED SITE PLAN SHEET NUMBER: A -la NOTE: PROPOSED ANTENNA PLACEMENT LOCATION TO BE FIELD CONSTRUCTION TO AVOID ANY INTERFERENCE OR SHADOWING SHADOWING OF (E) ANTENNAS IS DISCOVERED DURING CONSULTING GROUP INC. FOR DESIGN REVISION PRIOR VERIFIED BY GENERAL CONTRACTOR PRIOR TO E FI ANTENNAS. IF INTERFERENCE OR FIELD VERIFICATION, PLEASE CONTACT ALLPRO TO ANY NEW ANTENNA INSTALLATION, MOUNT ANALYSIS PERFORMED BY TOWER ENGINEERING NOTE: NOTE. ALL INSTALLATIONS PROFESSIONALS FOR ATC WITH TEP PROJECT NUMBER: TOWER STRUCTURAL ANALYSIS BY SHOULD BE IN COMPLIANCE AMERICAN TOWER CORPORATION, 992110177582, DATED 08/29/18. THE ANTENNAS SHOWN ANWITY ANSI/ASAF TY STA AND ON THIS PLAN ARE FOR REFERENCE ONLY AND THE ENGINEERING# OAA736376_C3_03 DATED ANY OTHER SAFETY STANDARDS HEIGHT, LOCATION, AND MOUNTING SHOWN IN THE 08/03/18. NO NEW ANTENNAS OR rLnrv� rnernrctu run: \ Sprint STRUCTURAL ANALYSIS SHOULD SUPERSEDE THESE EQUIPMENT LOADS SHALL BE INSTALLED DRAWINGS. ON THE TOWER WITHOUT THE APPROVAL OF A STRUCTURAL ENGINEER 6580 Sprint Parkway Overland Park, Kansas 66251 PLANS PREPARED BY: gilil TOP OF TOWER 92'-0"t AGE TOP OF TOWER 92'-0"t AGE 9221 LYNDON B JOHNSON FREEWAY RAD CENTER OF OTHERS ANTENNAS 90'-0"t AGL RAD CENTER OF OTHERS ANTENNAS 90'-0"t AGL SUITE 204, DALLAS, TX 75243 ALLPRO Au FAX 866-364-8375893 NEW (3) RRUS 31 (1) PER SECTOR CONSULTING GROUP, INC. WWN A ACGI# 188-4676-4676 GI.COM RAD CENTER OF OTHERS DISH RAD CENTER OF OTHERS DISH 83'—O"± AGL RAD CENTER OF OTHERS ANTENNAS 83'—O"± AGL h RAD CENTER OF OTHERS ANTENNAS 79'-0"f AGL 79'-0"f AGL OL RAD CENTER OF SPRINT ANTENNAS NEW (3) RRUS-11 800 (1) PER RAD CENTER OF SPRINT ANTENNAS SECTOR AMERICAN TOWER 75'—O"± AGL 75'—O"± AGL 8505 FREEPORT PARKWAY (E) (3) DB874GI05AXY ANTENNAS (TO BE REMOVED) (E) (3) TTA MODEL# KMDAPS2050000 (TO BE REMOVED) NEW (3) AIR 6468 B41 ANTENNAS (1) PER SECTOR IRVING, TX 75063 ENGINEERING LICENSE: RAD CENTER OF OTHERS ANTENNAS � RAD CENTER OF OTHERS ANTENNAS 70'-0"t AGL 70'—O"± AGL (E) (3) HB—X—WM-17-65-05T ANTENNAS (TO) BE REMOVED) (E) (6) DB874H12OESX ANTENNAS (TO BE REMOVED) Li NEW (3) TPA65R—K�E)6D ANTENNAS PER SECTOR EF� �At TE 00 * • t +j �+ •� Administrative Approval �. _...CHfrY�11.ZHATNG ..... ................... •8• G� S I •._ �4 -� •= dot* � . . ... 8/30/18 DRAWING NOTICE: By �� �� /�•Q %• %� THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR I wl REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. Date REVISIONS: DESCRIPTION DATE BY REV MONOPOLE (E) 92' MONOPOLE ISMFOR REMW 08/10/18 JE A ISM FOR 00161FILMON 08/30/18 RP 0 SITE NAME: TX -DAL (E) (2) 1/2" COAX CABLE ATC NAME/ NO.: (E) 20' X 10' SPRINT/ (E) 20' X 10' SPRINT/ NEXTEL SHELTER NEXTEL SHELTER (E) (2) 1/2" COAX CABLE (E) (9) 1-5/8" COAX CABLE (E) 20' X 10' SPRINT/ NEXTEL SHELTER (E) 20' X 10' SPRINT/ NEW (3) 1.7" HYBRID CABLE NEXTEL SHELTER IRVINGMACKBERRY, 609143 SITE CASCADE: (E) CMU WALL TO BE REMOVED (E) CMU WALL DA52XC325 SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY N: SHEET DESCRIPTIOFt t ELEVATION • E FINISH GRADE E FINISH GRADE . O'—O"f AGE —O'f AGE SHEET NUMBER: A 2 r— EXISTING SITE ELEVATION FOR 24" X 36" PLOT — 3/16" = 1' 0 2' 4' 8'FOR FOR 11" X 17" PLOT - 3/32" = 1' ® A FINAL SITE ELEVATION 24" X 36" PLOT — 3/16" = 1' 0 2' 4' 8' FOR 11" X 17" PLOT - 3/32" = 1' ® B rLnrv� rnernrctu run: NOTE MOUNT ANALYSIS: \� AN ANALYSIS OF THE TOWER OR STRUCTURE HAS BEEN Sprint PERFORMED BY TOWER 1A ENGINEERING PROFESSIONALS (AZ 30°) FOR ATC WITH TEP PROJECT 6580 Sprint Parkway 1A NUMBER: 992110177582, DATED Overland Park, Kansas 66251 4C 2A SECTOR A (E) (3) HB-X-WM-17-65-05T (AZ 30') SECTOR A 08/29/18. THE ANTENNAS PLANS PREPARED BY: (AZ 270') (AZ 30') ANTENNAS (TO BE REMOVED) SHOWN ON THIS PLAN ARE FOR REFERENCE ONLY AND THE 9221 LYNDON B JOHNSON HEIGHT, LOCATION, AND FREEWAY (E) (3) DB874G105AXY ANTENNAS 3A MOUNTING SHOWN IN THE 3A SUITE 204, DALLAS, (TO BE REMOVED) NEW (3) RRUS-11 800 (1) PER STRUCTURAL ANALYSIS SHOULD TX 75243 (AZ 30') SECTOR (AZ 30') SUPERSEDE THESE DRAWINGS. L L P R O FAX 866-364-8375893 3C 4A 3CWWW.ALLPROCGI.COM CONSULTING GROUP, INC. (AZ 270°) (AZ 250') ACGI# 18-4676 (AZ 30') (E) (3) TTA MODEL# SECTOR C NEW (3) E6D SECTOR C O KMDAPS2050000 O ANTENNAS () PER TO BE REMOVED) SECTOR AMERICAN TOWER 2C 1G (AZ 270') 1B (AZ 250') 8505 FREEPORT 7 (AZ 150') RVING, TX 063WAY ENGINEERING LICENSE: (E) (6) DB874H12OESX ANTENNAS NEW (3) AIR 6468 B41 ANTENNAS 1B (AZ 135') 2B (TO BE REMOVED) (1) PER SECTOR (AZ 150') Admin�7-� �7 }�+ } O e� istrative DLIVC� App�DVpI SECTOR B NEW (3) RRUS 31 (1) PER SECTOR SECTOR B ����til\��� A� _OF rE,�• ��� . (AZ 150') (AZ 120') 1.. B r� `( ,25{(7 �1 b L'1 4B GC MUST VERIFY WITH 00 j ............................... . J • Y (AZ 150°) CHM) ZHANG J Date SPRINT FOR THE LATEST r�".................. RFDS BEFORE INSTALLATION • �4 Ir = TRUE NORTH 0' = TRUE NORTH S..... l EXISTING ANTENNA LAYOUT @ 75' NO SCALE A FINAL ANTENNA LAYOUT @ 75' NO SCALE B 8/30/18 3" I.D. (3.5" O.D.) SCH 40 3" I.D. (3.5" O.D.) SCH 40 SPRINT ANTENNA x 8'-0" GALV. PIPE x 8'-0" GALV. PIPE DRAWING NOTICE: CCI TPA65R–KE6D (1) PER SECTORRRU'S MOUNTED TO PIPE THESE DOCUMENTSARE CONFIDENTIAL AND ARE THE SOLE PROPERTYOF w/ RRU MOUNTING KIT SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. RRU'S MOUNTED PIPE REVISIONS: w/ RRU MOUNTING KIT 3" I.D. (3.5" O.D.) ( DESCRIPTION DATE BY REV ISM FOR REMW 08/10/18 .E A SCH 40 x 8'-0" ISSIIFD FOR 01361R11C110N 08/30/18 RP 0 GALV. PIPE 'o�aoa �00000 (3) ERICSSON NEW (3) ANTENNAS MODEL# AIR 6468 B41 �oaoc(3) ERICSSON RRUS-11 (1) BY ERICSSON (1) PER SECTOR 000� 000c- PER SECTOR RRUS-11 (1) PER SECTOR ''`'00000 �ooao e �g0000 SITE NAME: w °0 z TX -DAL (3) ERICSSON SECURE EXCESS ATC NAME/ NO.: RRUS-31 (1) CABLES w/ COAX PER SECTOR (3) ERICSSON BLOCKS & GROMMETS IRVINGMACKBERRY , RRUS-31 (1) 609143 PER SECTOR SITE CASCADE: SECURE EXCESS CABLES w/ COAX COIL EXCESS CABLES &SECURE BLOCKS & GROMMETS TO PIPE MOUNT. DO NOT EXCEED DA52XC325 BEND RADIUS CUT POWER CABLES — TO LENGTH & TERMINATE AT MIMO SITE ADDRESS: — — 1850 E. BELTLINE ROAD MOLDED BREAKOUT SLEEVE COPPEL, TX 75019-9607 HOSE CLAMP TO SUPPORT MOLDED BREAKOUT SLEEVE DALLAS COUNTY MOLDED BREAKOUT SLEEVE HOSE CLAMP TO SUPPORT SHEET DESCRIPTION: MOLDED BREAKOUT SLEEVE NEW (3) 1.7" HYBRID CABLES ANTENNA LAYOUT & SECURE EXCESS COIL EXCESS CABLES & SECURE (1) PER SECTOR CABLES w/ COAX TO PIPE MOUNT. DO NOT EXCEED MOUNTING DETAILS BLOCKS & GROMMETS BEND RADIUS CUT POWER CABLES TO LENGTH & TERMINATE AT MIMO SHEET NUMBER: A-3 ANTENNA MOUNTING DETAIL NO SCALE C ANTENNA MOUNTING DETAIL NO SCALE D rLnrv� rr<ernrctu run: a \� Sprint 6580 Sprint Parkway NOTE: Overland Park, Kansas 66251 RRUS CAN ONLY BE IF PAINTED ON SOLAR SHIELD. PLANS PREPARED BY: 9221 LYNDON B JOHNSON FREEWAY SUITE 204, DALLAS, TX 75243 L L P R O PHONE: 972-231-8893 oomo N FAX:866-364-8375 ommo CONSULTING GROUP, INC. WWW.ALLPROCGI.COM ACGI# 184676 TECHNICAL SPECIFICATIONS AIR 6468 841 mmoo e o omo ® e o e Connection interfaces m®®m e o e Grounding Point 2Y M6 tot to Support an M6 dual Ca6k lug. 48 v DC Power Supply: 2 -wire Ns conn SEW ®mmmo�ees Date l optical ecpni: LG IDR SFP) Wnh support for FWAXS. ®®-memeov Dols 2Optical eCPR1: LClon8FP)wknsupport for FuiLX8 Optional Synch mnhatfan Timing LC SFP] whh support for FuIA%S. AMERICAN TOWER mmmm®®®mmm= ma®m®®mme� (AUX): Lan Tri Band Twelve -Port Antenna Extemet Ala mtrAPC Ughl l n terrace Anl-Dl N connector. 14 pin TPA65R-H£GD DATASHEET 8505 FREEPORT PARKWAY `o Op[Icallndicatcn LEOs IRVING,TX75063 m s m rxMoitvr, SMA - Sim foot a.8 m! TnBand, twelve port antenna with a 65' azimuth beomwldth ENGINEERING LICENSE: m BASEBAND CONFIGL RATION Humbd of besebend units depending on cmTiwwlltn, covering 698-960 MHz and 1695-2690 MHz frequencies - Eight wide high band ports covering 1695-2690 MHz end four wide low AC :eSSOIRleB fn5taaeticn accessorxrs ere evalfebte from the Eacsson Redv Sole system 11W[trpra. band ports covering 698-950 MHz in a singte antenna enciosu'e Full Spectrum Compliance 698.960 MHz 11695.2590 MHz -• I As a noun of more xarlrpert I.yel r.purq�cn: mind Iudri em np.rding pros c1 hobil,y."ern Willed t. Pmn out cerci hAx 11A miry alis. when prawns are moUrttln e.nmodnary "Taunq cmd4 on. -ba mahawcal oasgn Is bas as on ii mtaamentat cmobons which arc ewer m a - Innovative Low and High Band Array conligu ra tion allows for 4T4R (4x4 xceedmq Gass { 1 as saec.hed n Ens 900 019-I-{ •rid marshy raspeps the staticmrcM�ul loed+nposed Wn an AiR unA I Y wnd et n.esimum MIM01 an Law Band and Dual 4T4R (4x4 MtMO) High Band Arrays- using full � ueIftOn Win Weds In }ley gateN eat en Cel[ ' mo wrh rpfiiiw a m wind prerwre PIX fMte a muni! and into spaprL rumps, mi Inbarmnipn mbe cli 1991-1� GB 50006. Pd. bar Erasson H dl. length arrays (non stacked), all in a 21.0- (534mrW width enclosure, an y �1 r }��r nestle con udenN end cdeul ate ee cord nqm or clamps and meundinq eaessedea ae apeei0ed Cuvtum.r Rodur[ tnprmenon dorun vriWSron mus: b• used. Fxyaordmry opw'edrp eon dl wis. such w M1vary Icing a.eu=.,l dynamo str.sr Indust ry First _� _OF p. .............}' ' tang ,enlm a. yda or—dw,ng:,.00ze umewr gal may 4n 11 In c,W waarraya.r an AIR .1 r,t 1 mua ne�nm Ln ami Nen ca,.>e me Uni W ran to Ina - LTE Optimized FBR and SPR performance. providing for an efficient use of � �1: •. 1� ERICSSON RRUS-11 800MHZ grows. ih rsr races mull b. rynrdand army Ilia Sar pa nniny prxaas valuable radio capacity j -DIMENSIONS H x W x D ( ) p 9 p LTE PerformanceBoresi ht and %PD and USL erformance, essential for 0 / _ * 17° x 17.8' x 9.2° (INCLUDES SUNSHIELD) •• •'••"• •"•J 431.8 x 452.1 x 233.7 (mm) a ExceedsminimumP[Mpertonnancerequirements �.••�••CHfY0t &;;Z —WEIGHT: 54 LBS (24.5 kg) 0 Equipped with new4.3-IO connector, which is 40%smaller than traditional 7116 DIN connector j- ... 64 '••�'a•.er -• .1I•a%a•' •� -CLIMATE: -40°C TO +55`C FANS, Equipped with 3 field replaceable. integrated AISG 2.0 compliant Remote A ••. (SELF CONVECTION SILENT, NO IP55) ti T �ypp� Etectricat T1I1 LRET) Controllers [Type1 External} •,• ( do -POWER CONSUMPTION: 200 WATTS (TYP.) T o o • • 1, S/ �� r Overview 1 The CCI n port antenna, with high array IsoHz ■.Ra an pots o band ports covering 1695-2690 MHz and [dui wide {ow band pa is covering is covering 169 598-960 MHz. The antenna provides the capability to deploy Dual 4)-4 8/30/18 0 p a Multlple-input Mu lllple-out put [MIMO) in the high band and 04 MtMO across `-band ports. The C012 -Port high band ports have independent tilt control between left andnghtamennaarays. RRU-11 NO SCALE A DRAWING NOTICE: AIR 6468B41in[arfaces In this three RET configuration, the 1st RET is dedicated for the }cur Law Band The 2nd RET is dedicated for the four Left High Band THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR SOLUTION D V E R 1! I E 1111 V I _[ Ij�ylj ports. ports and the 3rd RET Is dedicated for the four Right High Band ports. This RET arrangement altows far complete flexibility In coverage control between left REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. REVISIONS: . and right high band antenna arrays. RRUS 31 825 — KRC 118 159/1 DESCRIPTION DATE BY REV CCI antennas are designed and produced to 1509001:2oo8 certification ISSUED FOR RENEN 08/10/18 ,E A 4T/4R RRU Band 25 standards for reliability and quality in our stale -of -the -art manufacturing facilities. ISM FOR CM611111 1 08/30/18 RP 0 160W, 40W1Antsnna 65111111 Instantaneous Bandwidth -400C to +55°C Applidations RBS6102, 6101, 6601 Support Dual 4x4 MIMO for the High Band and 44 MIMO Low Band ports Ready for Network Standardization on 4.3-10 DIN con nectars SITE NAME: With CC I's TriBand antennas, wireless providers can connect multiple Ericsson RRU Interfaces to a single antenna, reducing tower load lease expense. deployment deployment time and Installation costs TX - -48 V DC Input -DAL - 2 x 5Gbps CPRE - Connects to a XMIJ it ATC NAME/ NO.: - External RET and Alarm Support L I IRVINGMACKBERRY, 609143 AIR 6468 B4 7 size and vertical bracket spacing 5 www.ccipr❑ducu.com E% T E N I R G W I R E L E S S P E R F R M A K L E SITE CASCADE: e�1e z 0610412[118 r�„ya mww¢spaform as.a.en m:M.a Iten9m 11 1 Wi.eaAamv.,.ueeaa cluArye,.hr• •Wsl C4 gnr r:sn maecsavA,m . u°• DA52XC325 SITE ADDRESS: Weight [with and 27 kg (25-5 kg) 1850 E. BELTLINE ROAD without brackets] 59.5 Ib (55.1 Ib) COPPEL, TX 75019-9607 DALLAS COUNTY Volume 30 L SHEET DESCRIPTION: Size (without bracket) 300 x 237 x 420 mm 11.8 x 9.3 x 15.5 in EQUIPMENT SPECS SHEET NUMBER: A—`"r/� RRU-31 B AIR 6468 B41 ANTENNA SPECS NO SCALE C TPA65R–KE6D ANTENNA SPECS NO SCALE D PLANS PREPARED FOR: Sprint 6580 Sprint Parkway Overland Park, Kansas 66251 - PLANS PREPARED BY: 9221 LYNDON B JOHNSON FREEWAY SUITE 204, DALLAS, TX 75243 LL P R O FAX:866-364-8375893 CONSULTING GROUP, INC. WWW.ALLPROCGI.COM ACGI# 184676 AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 LICENSE: E�F� A� a rE '� ��CHfYL1 ZFIANG ••• � ............................... ..J 28�1.87� �� 8/30/18 —DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. —REVISIONS: DESCRIPTION DATE BY REV ISSUED FOR REMW 08/10/19 E A ISSUED FOR DONs1R11C ON 08/30/19 RP 0 — SITE NAME: TX -DAL — ATC NAME/ NO.: IRVING/14ACKBERRY, 609143 — SITE CASCADE: DA52XC325 — SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY — SHEET DESCRIPTION: EQUIPMENT SPECS — SHEET NUMBER: A -4A YP:.Fr pr� I 0'04: uy c 1907irL15WN2 S�su'•uU •L•I�w 4flttL _ 1 1:11 -AL �•IA.. - -•, •• SPRINT CAB'.€ COLOR CODE RR, CAB_E WAR CNG LDCA71ONS DIAGRoW welr_al reser caaL r r_nL ne r_nnwr. CSE.E r+rmw.xsr:a. -rs..[ TA 1900 Mhz2T4R/4T4R X 1 EMI TL ­117 •N'LL RE xta wxE 'Cr --F ` vK n 1 S BROWN .o iu�E 9!S AIU >riMa4r0 :SIC RHO 0.11 -1, :. tHLL aE ccLN =Ib X 7 IAL [''• ][T •ar r •LE Y w_ •W 71E T.+�..1YrO1 x'Ma w: + _ m s rttD _ !;RANGE E41E4%r, M FFL CA T4V WW w.LNw 8T8R 1 W1 c WS 9111L IE AiTX. Ii ""L'x M- mM a TK h04o of M 2 RRU Count 1AnW a eaweE NO TALE -1 G+J/w ML Nam%.r.UF0+5 sttaL K OLM x JtEh Carni AwH I,) nT ]F !/C 4Lx ewx M Wil M ar ll r .6WER. ERC Hybrid cable has 5 power &6fiber pairs/sector. 25 MHx RADIO CALIBRATION CABLE COLOR CODE 4p1[ Standard Capacity RF Configuration Capacity RF Configuration�RRU Count Power Palm Fiber Pairs Total Hybrid (Fiber) Cable Count/ Sector Comments Power Pairs�Fiber Pairs Total Hybrid(Fiber) Cable Count/ Sector Comments y7LWr:A:iE.Bd 1900 Mhz2T4R/4T4R y}yIeG±®: 1 • 2 OwE SO TL I[ 1 S BROWN .o iu�E 9!S AIU >riMa4r0 :SIC RHO 14J[nrRN3 Fp'.7I4NM Ses"F 7k6 %Kx - •' E 7 5 s rttD _ !;RANGE 2500 Mhz 8T8R 1 • 7 FURPI[ NO TAPE 2 RRU Count Power Pairs a eaweE NO TALE -1 G+J/w t 1 Ecrl , ERM GREEK JtEh 1 7 2 BLUE OLLE 2 19M Mhz 2T4R/4T4R ■r. 2 4 +sHf1E -HIT[ 1 761640A�gY-�y ERC Hybrid cable has 5 power &6fiber pairs/sector. 25 MHx RADIO CALIBRATION CABLE COLOR CODE 4p1[ Standard Capacity RF Configuration Capacity RF Configuration�RRU Count Power Palm Fiber Pairs Total Hybrid (Fiber) Cable Count/ Sector Comments Power Pairs�Fiber Pairs Total Hybrid(Fiber) Cable Count/ Sector Comments PLANS PREPARED FOR: Sprint 6580 Sprint Parkway Overland Park, Kansas 66251 PLANS PREPARED BY: 9221 LYNDON B JOHNSON FREEWAY SUITE 211, DALLAS, TX 75243 AL L P R 0 FAX:866-364-8375893 CONSULTING GROUP, INC. WWW.ALLPROCGLGOM ACGI# 184676 Iii AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 LICENSE: ��CHfYL1 ZFiANG ••• � ........J281.......87............. 8�1.87. .� -yrVIIFIR„c•-.� 8/30/18 DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. REVISIONS: DESCRIPTION DATE BY REV ISSUED FOR REIIEW 08/10/18 E A ISSUED FOR CMEMLICTION 08/30/18 RP 0 SITE NAME: TX -DAL ATC NAME/ NO.: IRVING/HACKBERRY, 609143 SITE CASCADE: DA52XC325 SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY SHEET DESCRIPTION: SPECS SHEET NUMBER: A-5 y7LWr:A:iE.Bd 1900 Mhz2T4R/4T4R 1 1) 1 CARLE-%W'M 9!S AIU >riMa4r0 :SIC RHO 14J[nrRN3 Fp'.7I4NM Ses"F 7k6 2TZ 4 4 7 5 OPA�G[ !;RANGE 2500 Mhz 8T8R 1 1 2 RRU Count Power Pairs Fiber Pairs Total Hybrid (Fiber) Cable Count/ Sector -1 G+J/w t Gi�I JtEh 1 1 2 19M Mhz 2T4R/4T4R ■r. fAV l 1 761640A�gY-�y A 8T8R 1 1 1 configuration. If a rooftop (or non standard tower configuration), then an individual (8 pair) Fiber cable will be required/sector. 7 2 pl,e ELLE 800 Mhz 2T2R 1900 Mhz 800 Mhz T$LfYI '& ar' T$ (Ax a41E1 2 1 4 1 a s ■40MN eR vr. 4) Note: an additional single (8 pair) Fiber cable will be requried to support a standard 3 sector tower 2 iew�F, Ys— 1 rB1.ow "LLD" ^w T$:d 1rT'E BETN� TM FSE. E, f"� 2500 Mhz 2 4 %WK ■ME 3. A l' :W ' 41 'E'AVATE ME :+'LE CDLCN 0009 FRW 1HE PQE,.CT• FkMQPAt r C01.414 GULF- 7LE •• '= !,L)k Alws Flom T(i - 1900Mhz 800 Mhz configuration. Ifa rooftop (or non standard tower configuration), then an individual (8 pair) Fibercable 2 2 2 2 4 3 2 5 NEC R® 2) 2 will be required/sector. 4. THE 7' COLDRED i1Ti(5, SHELL E✓tC1S BE W.WPUk 4 NhM.lf OF 3 ^3k Ya t CAt n r' ka70° I -- _ _ _ _ 1 1 2 2 r, CRIT 01q'f 2500 Mhz 8T8R PLANS PREPARED FOR: Sprint 6580 Sprint Parkway Overland Park, Kansas 66251 PLANS PREPARED BY: 9221 LYNDON B JOHNSON FREEWAY SUITE 211, DALLAS, TX 75243 AL L P R 0 FAX:866-364-8375893 CONSULTING GROUP, INC. WWW.ALLPROCGLGOM ACGI# 184676 Iii AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 LICENSE: ��CHfYL1 ZFiANG ••• � ........J281.......87............. 8�1.87. .� -yrVIIFIR„c•-.� 8/30/18 DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. REVISIONS: DESCRIPTION DATE BY REV ISSUED FOR REIIEW 08/10/18 E A ISSUED FOR CMEMLICTION 08/30/18 RP 0 SITE NAME: TX -DAL ATC NAME/ NO.: IRVING/HACKBERRY, 609143 SITE CASCADE: DA52XC325 SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY SHEET DESCRIPTION: SPECS SHEET NUMBER: A-5 1900 Mhz2T4R/4T4R 1 1 2 800 Mhz 2TZ 4 4 2 2 3 High Capacity RF Configuration RRU Count Power Pairs Fiber Pairs Total Hybrid (Fiber) Cable Count/ Sector Note: an additional single (8 pair) Fiber cable will be requited to support a standard 3 sector tower ■r. '� o.o }a10"I"'• NOTES' 3) 2500 Mhz 8T8R 1 1 2 2 configuration. If a rooftop (or non standard tower configuration), then an individual (8 pair) Fiber cable will be required/sector. �r ALL cAvLlti 54iLL Fri MLRuQ ARH it wtA, W S'1WILICE]:. UL AMROeM T+f'E 1900 Mhz 800 Mhz 2T4R/4T4R 2T2R 2 1 2 1 4 1 Ix Www` - ,rte {{ _[wY ly { 51,.,..q.,,.�, 7. THE FIRST' 9WH WILL 9[ CMILST M 7M m or THE 'APLE Ahn S -ACC APRiOx1"M' 2' FNOY THE N9 COti�R, wr/TY[r6Kt�. CH _:•E.W--7.A CrLINM- W" iHNL NE F I- SNC( BETP¢.N. FMH sln�• F04 W COLE L'•E WE4. MID VO SPACES 4) 2 Note: an additional single (24 pair) Fiber cable will be requried to support a standard 3 sector tower configuration. if a rooftop(or nonstandard tower configuration), then an individual(Spair) Fibercable will be required/sector. BETN� TM FSE. E, f"� 2500 Mhz ST8R 1 1 2 3. A l' :W ' 41 'E'AVATE ME :+'LE CDLCN 0009 FRW 1HE PQE,.CT• FkMQPAt r C01.414 GULF- 7LE •• '= !,L)k Alws Flom T(i - 1900Mhz 800 Mhz 2T4R/4T4R 2T4R/4T4R 2 2 2 2 4 3 COLE SP / Of PIACE7 NUT T EACH OTHER! rr(H NO SPICES cM 4. THE 7' COLDRED i1Ti(5, SHELL E✓tC1S BE W.WPUk 4 NhM.lf OF 3 11110n■ROJNC WInOMOWL CABLES, AAO 'ME MLPE SNAL HE lZuT h THC SAY[ WrAM4 AS YUa34 AS P¢SNIAE. 5 VIES 911H ItQ% RKY Fast (4; StC"S PALL RED..PE AV=GkAL RAGS Fol ELCH '..M70R. FDU0WIvG THE R11TE IN 1,1I:71 rA Krry SITES WILL LILA[ THE 4E)rr CCI.CR IN 4E S=UMCE FOR ADDEL7V1_ CASH IN 96W SM. R- 6- HVRW 9KW fJ1HC -.MILL 0E '•CC7UR 111[MFl01 h7i:Fi THC CA LONl r ' CH FREOLIERrr UkNOLF5, ON 171E SE•LfrIE, ON THE VAIN LINE VFPN EKF Or SENMM AND R&15qE AHO LATER THE FIREW%T UtiF 4NI as (IIEOLTSAj A5 +AELL AS HUCHE AND ArNX AW E1TW4Wg ON pRF- 7. 1!C 1&* TRt mK' wt/ NOT of RARRC7 wOH THE rRM40%CT COWS. AS IT CWAM ALL FRMIiENr.ES E. P4tho%AL POPM AIM ANO FIRER 9LKDLEs SFYLL IS iAFE8C7 ATEI 90TH TI[ CAME " MEOLiCHCy, COLOR CODING NO SCALE A ERC CABLE SPECS NO SCALE B PLANS PREPARED FOR: Sprint 6580 Sprint Parkway Overland Park, Kansas 66251 PLANS PREPARED BY: 9221 LYNDON B JOHNSON FREEWAY SUITE 211, DALLAS, TX 75243 AL L P R 0 FAX:866-364-8375893 CONSULTING GROUP, INC. WWW.ALLPROCGLGOM ACGI# 184676 Iii AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 LICENSE: ��CHfYL1 ZFiANG ••• � ........J281.......87............. 8�1.87. .� -yrVIIFIR„c•-.� 8/30/18 DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. REVISIONS: DESCRIPTION DATE BY REV ISSUED FOR REIIEW 08/10/18 E A ISSUED FOR CMEMLICTION 08/30/18 RP 0 SITE NAME: TX -DAL ATC NAME/ NO.: IRVING/HACKBERRY, 609143 SITE CASCADE: DA52XC325 SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY SHEET DESCRIPTION: SPECS SHEET NUMBER: A-5 v Ground Mount Extemal I OA0Z/!7xternal Monopole Equipment & Battery Cabinets can be pad ed with different mounting kits. Features • Security feature within access panels to prevent unauthorized entry • Tested to NEMA 3R (fiber storage compartment only) • Designed to meat UBC seismic Zane 4 standards Compatible with External Monopole Cabinets: • 204816 / 2000004543 Equipment Cabinet MERV 13 2M19/2000004545 Equipment Cabinet MERV 16 • 2M96/2000004486 Battery Cabinet Kit Contents • Mounting Tubes: 90mm tube steel. Weight: 15lbs, • Mounting tubes are also used in Pale Mount application for service ladder/platform attachment • Ground Mount Brackets: 6 gage steel, Weight: 10lbs • Fiber cc m partm a nt: .125 polyester powder coat aluminum, RAL 7035 grey. Weight: 130lbs • Stainless steel mounting hardware • Installation guides 22 Mounting Footprint 2000004694- 205818 / 2000004685 000004694-205818/2000004685 <-2000004793 2000004686 205819 / 2000004686 - -J 205819 2000004686 Battery cabinet ground mount brackets and mounting tubes 25 112" 205818 2000004685 Equipment cabinet ground mount kit with fiber storage 14 3/8" TED 2000004709 Equipment cabinet ground mount brackets 10 112" TSD 2000004694 Equipment cabinet mounting tubes 18125 East Euclid Avenue ■ Spokane, Washington 99216 sYSTF►� 599.755.0341 a www.puroellsystems.00m T8D 2000004783 Equipment cabinet fiber storage compartment t) Equipment Cabinet External The External Monopole Equipment Cabinet is designed to house Radio Access Network (RAN) equipment, fiber or microwave backhaul, and AC -DC rectifiers and DC distribution. It is externally mounted to a pole - Cabinet Features + Polyester powder coated aluminum; RAL7035 grey • Weight:4501bs. • 19" rails; 30 rack units (RU) INFront and rear doors with three point latching system and Combination handles GPS antenna mast • DC and AF surge protection devices Thermal Management • Direct Air Cooling (DAC) with two Fans; Front -to -hack airflow; door mounted MERV 13 and MERV 16 filter options 15DOW healer • Designed to operate in -40°C to +51-7^C ambient temperature Battery Compartment • Segregated. vented compartmenl housing (1) -48V string 19DAhr batteries • Direct Air Cooling (DAC) with one fan • Optional battery heater mats - one mat per shelf • Designed to meet GR -487 hydrogen outgassing requirements 16125 East Euclid Avenue. Spokane. Washington 99216 sr srF=ons 509.755.0341 n www-puroatlsystems-corn Rectifier System • 19";5RU - 208.240VAG AC input - -48VDC 30DOW rectifiers - (3) 150A battery breakers - (22) 25A, (2) 20A, (8) ICA load breakers; critical and non -I • Efficiency: 93.5% typical; 951/6 max • Controller with USB, RS485 and Ethernet parts, LED o digital and relay inpuWoutputs, AC & DC over and undE and battery low -voltage disconnect • UL/CSAIIEC 60950.1 Standards • Designed to meet GR -487 environmental standards f inseatlrodent intrusion ULSOSA certification pending • Oesigned to meet seismic Zane 4 standards 204816 2000004543 EquipmE 204819 2000004545 Equipme [,aze-tx] 72-0 3000 a66 7 Dimensions shown in inches [millimeters] Battery Cabinet External The External Monopole Battery Cabinet is designed to house twn 48V strings of 19CAhr batteries It is externally mounted to a pole - Cabinet Features • Polyester powder coated aluminum; RAL7035 grey �,'e'riqned Weight:2001b5. •Four battery shelves I two batteries per sholfFront door with three poird latching system and combination handle hermal Management ®Direct Air Cooling (DAC) with twofans 204396 2000004496 Batlery Cabinet �� to operate in -40`C 204397 40170017864 Battery heater mat opt ion to +51.7•C ambient temperature • Optional battery heater mats - one mat per shelf Standards - Deigned to meet UL 2415 standards • D.Osigned to meet UBC seismic Zone 4 standards • Designed to meet GR -487 requirements for wind driven rain and1 hydrogen outgassing'� I a e T [18291 i.U'96■■ a a 110a•g 1 X20.0 [5081 Dimensions shorn in inches [mifl-wT rs] ► 18125 East Euclid Avenue ■ Spokane, Washington 99216 �rsT,=n.s 500.755,0341 n .pun lkystems.cam PLANS PREPARED FOR: Sprint 6580 Sprint Parkway Overland Park, Kansas 66251 PLANS PREPARED BY: 9221 LYNDON B JOHNSON FREEWAY SUITE 204, DALLAS, TX 75243 LL P R O FAX: 866-360375893 ;ONSULTING GROUP, INC. WWW.ALLPROCGI.COM ACGI# 184676 AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 ENGINEERING LICENSE: 1AtEOF iY �' ' • � • •'� rrji .... ..... CH4Y0 ZZiHANG ............................... 28.187 .�. 8/30/18 DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITrEN CONSENT OF SPRINT. REVISIONS: DESCRIPTION DATE BY REV Issllm FOR REVIEW 08/10/18 E A ISSIIFD FOR CONSTRUCTION 08/30/18 RP 0 SITE NAME: TX -DAL ATC NAME/ NO.: IRVING/HACKBERRY, 609143 SITE CASCADE: DA52XC325 SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY SHEET DESCRIPTION: EQUIPMENT SPEC SHEETS SHEET NUMBER: A -5A NEW 200A NOTES METER/DISCONNECT SWITCH 1 2 CG SHALL REFERENCE ALL SPECS FOR "CONNECTING THE POWER SUPPLY" OF THE NEW INSTALLATION DOCUMENTS, FOR ALL P P M OOp CONNECTION SPECIFICATIONS. N G NEW 200A SPRINT NEW SERVICE 200A PPC CABINET W/INSTALL GROUND 15A CIRCUIT BATTERY CABINET 15A 0 20A �\ o 100A O TO LOADS o PURCELL (REFER TO PANEL TO LOADS (REFER TO PANEL SCHEDULE) E CABINET 0A �� O 4 ELECTRICAL ONE—LINE DIAGRAM NO SCALE A NOTE PowER/FTBER 1BD 20'-0» \� NEW (3) 1.7" HYBRID CABLE Q O \ I i 0 (E) ICE BRIDGE U \ (E) OVERHEAD Q CABLE TRAY 0 0 POWER SITE PLAN FOR 24" X 36" PLOT - 3/4" = 1' 0 6" 1' 2' B FOR 11" X 17' PLOT - 3/8" = 1' CIRCUIT SCHEDULE NO FROM TO CONFIGURATION 1 UTILITY SOURCE METER/DISCONNECT 3-#3/00 (1) #8 GND IN 2" PVC CONDUIT 2 METER/DISCONNECT TRANSFER &LOAD CENTER (3) #2 AVC,0 (1) #8 GND IN 1-1 /2" CONDUIT 3 TRANSFER &LOAD CENTER GENERATOR RECEPTACLE (3) #2 AVC,0 (1) #8 GND IN 1-1 /2" CONDUIT SCHEDULE) 6 (3) #2 AWG, OTRANSFER &LOAD CENTER SPRINT ECAB (1) #8 GND IN 1-1 /2" O PLANS PREPARED FOR: Sprint 6580 Sprint Parkway Overland Park, Kansas 66251 PLANS PREPARED BY: 9221LYNDON BJOHNSON FREEWAY SUITE 204, DALLAS, TX 75243 ALLPRO FAX 866-364-8375893 CONSULTING GROUP, INC. WWW.ALLPROCGI.COM ACGI# 184 676 AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 LICENSE: OF 8/30/18 DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. REVISIONS: DESCRIPTION DATE BY REV ISSUED FOR RENEW 08x0/19 .i A ISSUED FOR CONSTRI1Cllp! 08/30/18 RP 0 SITE NAME: TX -DAL ATC NAME/ NO.: IRVING/HACKBERRY, 609143 SITE CASCADE: DA52XC325 SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY SHEET DESCRIPTION: ONE -LINE DIAGRAM & PLAN SHEET NUMBER: E-1 CONDUIT O SPRINT ECAB SPRINT BCAB (2) 2 � CONDUITS FOR ALARM & DC PLANS PREPARED FOR: Sprint 6580 Sprint Parkway Overland Park, Kansas 66251 PLANS PREPARED BY: 9221LYNDON BJOHNSON FREEWAY SUITE 204, DALLAS, TX 75243 ALLPRO FAX 866-364-8375893 CONSULTING GROUP, INC. WWW.ALLPROCGI.COM ACGI# 184 676 AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 LICENSE: OF 8/30/18 DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. REVISIONS: DESCRIPTION DATE BY REV ISSUED FOR RENEW 08x0/19 .i A ISSUED FOR CONSTRI1Cllp! 08/30/18 RP 0 SITE NAME: TX -DAL ATC NAME/ NO.: IRVING/HACKBERRY, 609143 SITE CASCADE: DA52XC325 SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY SHEET DESCRIPTION: ONE -LINE DIAGRAM & PLAN SHEET NUMBER: E-1 NOTES rv{rva M—Lu rum: U Sprint 1. APPLY NO—OX TO LUG AND BAR CONTACT SURFACE. DO NOT COAT INLINE LUG. 6580 Sprint Parkway Overland Park, Kansas 66251 INSTALL (3) TOTAL INSTALL (3) TOTAL PLANS PREPARED BY: (1) PER SECTOR. (1) PER SECTOR NOTE: APPLY NO OX TO NEW CONNECTIONS. 9221 LYNDON B JOHNSON FREEWAY SUITE 204, DALLAS, TX 75243 LL P R 0 FAX:866-364-8375893 RRU-31 65MHZ RRU-11 800MHZ NEW DC POWER TO (6) RRUs CONSULTING GROUP, INC. ACG# ALLPRO1846 6CGI.COM PROPOSED FIBER do (E) POWER JUMPER AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 SPD SPD O O O O O O O O O O O O O o ENGINEERING LICENSE: O O O O O O O O O O O O O ° PROPOSED FIBER k (E) POWER JUMPER O O O O O O 0 0 11110 O O O O 0 O O O O 0 O O O O 0 O O O O 0 O O O O 0 O O O O 0 O O O O 0 O O O O 0 O O O O O O O 0 0 O O O.............. O; O 0 O 7I� 00 l• .... HfY11.ZHANG • •� ��• ••28•1 a%' •••� i t •S+f "' NEW BUS BAR DC CIRCUIT BREAKERS EXISTING N.V. DC BUS BAR 8/30/18 DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINTANDMAY NOTBE REPRODUCED, DISSEMINATEDOR DC ONE LINE DIAGRAM NO SCALE A DC POWER DISTRIBUTION NO SCALE B REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. REVISIONS: DESCRIPTION DATE BY REV ISM FOR REAV 08/10/18 JE A ISSN FOR 0136MMON 08/30/18 RP O SITE NAME: T TX—DAL ATC NAME/ NO.: IRVINGMACKBERRY, 609143 SITE CASCADE: DA52XC325 SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY SHEET DESCRIPTION: DC POWER & DISTRIBUTION SHEET NUMBER: E-2 DETAIL NOT USED NO SCALE C DETAIL NOT USED NO SCALE D LEGEND: 1121LYNDONB1011SO1 FREEWAY EXISTING GROUND RING TX 75243 L L P R 0 #2 AWG TINNED SOLID BARE CU (GROUND RINGS SHALL LILTING GROUP, INC. WWW.ALLPROCGI.COM ACGI# 18-0676 BE 2'-6" BELOW GRADE) A CADWELD CONNECTION (EXOTHERMIC WELD) ■ MECHANICAL CONNECTION 0 GROUND ROD ® TEST WELL & GROUND ROD NOTE: ONLY SOME SECTION SHOWN FOR CLARITY 1 PURCELL ECAB PURCELL BCAB PIPE MOUNT GROUNDED TO SECTOR BAR (TYP) / NEW SECTOR GROUND BAR (TYP.) (TO BE FIELD VERIFIED) NEW GROUND BAR 1 SPRINT ANTENNAS GROUNDED \ TO SECTOR BAR (TYP.) NEW GROUND LEAD \ FROM NEW EQUIP TO TIE INTO GROUND BAR (TYP) RRU GRO E, TO SECTOR BAR (TY 4 ---------- b b GROUNDING PLAN A ANTENNA GROUNDING PLAN(TYPE NO SCALE 6 PREPARED FOR: Sprint 6580 Sprint Parkway Overland Park, Kansas 66251 i PREPARED BY: 1121LYNDONB1011SO1 FREEWAY SUITE 204, DALLAS, TX 75243 L L P R 0 FAX: 866-364-8375972-23"893 66364-835893 LILTING GROUP, INC. WWW.ALLPROCGI.COM ACGI# 18-0676 AMERICAN TOWER 8505FREEPORT PARKWAY IRVING, TX 75063 LICENSE: y y�1�11%" EN� F t Q. rE. >t 8/30/18 DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINTAND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF SPRINT. REVISIONS: DESCRIPTION DATE BY REV ISM FOR REVEIN 08/16/18 1 A ISM FOR CONSTRUCIRIR 08/30/18 RP 0 SITE NAME: �T TX -DAL ATC NAME/ NO.: IRVING/HACKBERRY, 609143 SITE CASCADE: DA52XC325 SITE ADDRESS: 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY SHEET DESCRIPTION: GROUNDING PLAN SHEET NUMBER: G-1 rv�rv� rnerNneu run: SYMBOL LEGEND A EXOTHERMIC CONNECTION INSTALL MOUNTING PIPE ■ MECHANICAL CONNECTION (TYP) #4 OR #6 AWG SOLID CU CONDUCTOR WITH GREEN, 60OV, THWN-2 INSULATION \l� Sprint INSTALL ANTENNAS (NP) M Overhand Pads, Kansas Parkway0 Sprint 66251 s EXISTING GROUNDING 0 0 0 0 0 o BAR ON WALL, FLOOR, PLANS PREPARED BY: INSTALL RRU N N OR ON ANTENNA TOWER FREEWAY (TYP) SUITE 204, DALLAS, TX 75243 JUMPER CABLES I I > > I I I = F I I I O OQ 0 0 0 0 3 0 0 . . PHONE: 972-231-8893 L L P R 0 X: 866-36"375 11 FWWW.ALL ROCGI.COM CONSULTING GROUP, INC. ACGI# 18A676 (TYP) I II II I I AL— FIBER & DC CABLES I I I 17 (TYP) Li _ _ - - _ _ - - ------ , I - _ _ _ - - I I - - I I TWO HOLE SPADE, TO BE USED TO CONNECT TO GROUND BAR AMERICAN TOWER 8505 FREEPORT PARKWAY IRVING, TX 75063 I I II I ENGINEERING LICENSE: BREAK OUT CYLINDERS I I I I (TYP) oomm I 0000011 ED] Do SECTOR GROUND........ ❑❑ ❑❑ BARS (TYP) - - - - - - UPPER GROUND BAR NOTES 1. APPLY NO -OX TO LUG AND BAR CONTACT SURFACE. DO NOT COAT INLINE LUG."""' 2, IF STOLEN GROUND BARS ARE ENCOUNTERED, CONTACT SPRINT CM FOR REPLACEMENT THREADED ROD KIT. OF W A �� '•�F�•''�� �1 �GL\Ti """" / CH4Y11 ZHANG %""•,"""""""""�"""' -p 2818 % •� l � 8/30/18 NEW ANTENNA GROUNDING DIAGRAM (ON TOWER ONLY) NO SCALE A INSTALLATION OF GROUNDING CONDUCTOR TO GROUNDING BAR NO SCALE B DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL ANDARETHESOLE PROPERTY OF DOCUSPRINE TSARECD MAY OTBEENTIAL NDAEITHEMINATEOPE D OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. INSPECTION WINDOW REQUIRED FOR ALL INTERIOR TWO -HOLE CONNECTORS REVISIONS: DESCRIPTION DATEBY REV MED FOR EIEMEW 08/10/18 & A OW FOR CONSMC71ON 09/30/18 RP 0 EXTERNAL TOOTHED BUTT CONDUCTOR INSULATION UP AGAINST 3/8"4x1 1/2" THE CONNECTOR BARREL S/S NUT SITE NAME: COLD SHRINK OR S/S LOCK APPROVED EQUAL TX -DAL WASHER S/S FLAT WASHER —� 1" MIN f- ATC NAME/ NO.: IRVING/HACKBERRY, 609143 LABEL APPLY JJ1111J SITE CASCADE: NO -OX -- ------ DA52XC325 TINNED COPPER S/S FLAT GROUNDING BAR DO NOT WASHER DISCONNECT SITEADDRESS: S/S BOLT (1 OF 2) COLD SHRINK OR APPROVED EQUAL 1850 E. BELTLINE ROAD COPPEL, TX 75019-9607 DALLAS COUNTY TINNED COPPER SHEET DESCRIPTION: GROUNDING BAR "DO NOT DISCONNECT" GROUNDING TAG ON ALL GROUNDING BAR INTERCONNECTS AND EQUALIZERS DETAILS SHEET NUMBER: V rT —2 NOT USED NO SCALE C TWO HOLE LUG NO SCALE D