DRC REPORT
Project Name , Lot , BkCOMMENTS
Address
Matt SteerCase Manager
02/21/2018Application Complete Date
Planned Development - Detail PD - New/Not In ConformancePlan Type/Workclass
PD-133R8-HC, Magnolia Office Park (Savannah)Project Description
Agency Reviewed By Review Date Plan Review Details
Building Suzanne Arnold 02/27/2018 1.Correct address on title blocks.
2.Provide screening wall details.
3.Sign plans are accepted as conceptual only; subject to
comprehensive review upon permit submittal.
4.Note construction type and designed occupancy type on
site plan.
Engineering George Marshall 02/28/2018 Standard Detailed Engineering - FYI Comment - There may be
additional comments gernerated upon detailed engineering
review.
Site Plan:
1. Show proposed fire hydrants on the Site Plan.
2. There appears to be a gap in the screening wall where it
abuts the Magnolia Park screening wall. Explore options to
close the gap. - UNRESOLVED
General - Engineering Plans:
1. All water meters and meter taps should be relocated and
connected to the 12” water line in SH121, not in the rear off of
the private fire line.
2. Establish end of City maintenance and beginning of private
maintenance of the proposed sewer line at the southeast
corner of the property. The sewer line across the rear of this
property will be private.
3. The drainage from area C-1 cannot be concentrated as it
leaves the site near the south west corner of the property. It
currently sheet flows off the property. If a non-concentrated
discharge cannot be achieved, then the curb opening should
be a curb inlet with a pipe system installed to the existing
system in Natches Trace. - UNRESOLVED
Fire Tim Oates 03/02/2018 General - 1. Show fire hydrants, riser rooms, and fire
department connections (FDC) on the site plan.
2. Riser rooms are required to be a minimum of 64sf to
accommodate all fire and life safety equipment. -
UNRESOLVED
1. Fire hydrants required every 300 linear feet along the fire
lane easement
2. FDC shall be detached, adjacent to a fire hydrant
Riser rooms shall be accessible from an exterior door. Room
shall be minimum 8'x8',
Parks John Elias 03/01/2018 No comments
Planning Mary Paron-Boswell 03/01/2018 General - - add note: All signage to comply with City
Ordinances
- need to provide min 80% masonry (brick/stone) per each
elevation - should exclude doors and windows
- what is secondary material? limited to 20%
- provide material board images on sheet - define brick 1, etc.
1 of 2
PD18-01-000215Plan Case ID
CITY OF COPPELL
DRC REPORT
Project Name , Lot , BkCOMMENTS
material name brand, specs, etc.
- what is accent material?
- monument sign need some clarification - sign cabinet
material? lighting? - UNRESOLVED
General - - Provide distance and bearings of lot
- Provide existing and proposed easements
- show and label sidewalk
- provide a colored exhibit differentiating perimeter, interior and
non-vehicular landscaping areas
- % of total site dedicated to landscaping
- provide typicals for islands - min sq ft required
- revise title block - see site plan comments
- add note 8: All landscaped areas shall be fully irrigated.
- no parking in first 20'
- What does "e", "S", "P", "N" stand for - found with trees etc.
- what is the herringbone area in between the buildings?
describe/label
- some of the listed plants/trees are not from our approved list
-re-check your percentages in landscape calcs
Replace October Glory Maple, Wax Myrtle, Drift Roses, Dwarf
Cherry Laurel with plants from approved plant palette. -
UNRESOLVED
Site Plan Review - - provide North arrow for vicinity map and
1"=1000' scale and more streets
- show deceleration lane in its entirety and list length(detail)
- No parking within 20' of front property line
- Unclutter numbering on dumpster on bottom east corner
- provide elevations for dumpster enclosure and screening
wall. Add note: shall meet city ordinance requirements
- Provide proposed lighting/photometric and shielding plans
- show 60' front yard setback, 30' side and 20' rear
- provide lot coverage %, impervious area
- Are you showing the fire hydrants?
- provide developer contact info
- what does *PBA really mean? Need to use gross sq ft for
calculations
- list # stories in site data summary table. It appears that you
used office ratio twice. I think one is supposed to be medical.
- I thought you were talking about providing an 8ft masonry
wall?
- title block should list project name, plat name, lot, block
acreage and sq ft
- variances so far include: parking within first 20'; >50%
parking in front yard (56%); short on trees per table provided
and % landscaped. - UNRESOLVED