Loading...
DRC CommentsPD18-07-000262Plan Case ID CITY OF COPPELL DRC REPORT Project Name Old Town Addition, Lot 1, BkgCOMMENTS 505 TRAVIS STAddress Matt SteerCase Manager 07/20/2018Application Complete Date Planned Development - Detail PD - New/Not In ConformancePlan Type/Workclass Coppell Arts CenterProject Description Agency Reviewed By Review Date Plan Review Details Building Suzanne Arnold Engineering George Marshall 07/26/2018 General - Match Existing Street Lights in Old Town. Show all existing Fire Hydrants. Show Riser Room Show FDC - UNRESOLVED General - Utility Plan: Relocate the FDC to the island between the driveways so it is more accessable from the fire lane. Show FDC line from riser room. - UNRESOLVED Engineering Kent Collins 07/25/2018 Standard Detailed Engineering - FYI comment - There may be additional comments gernerated upon detailed engineering review. General, dimension all curb return radii - UNRESOLVED Fire Tim Oates 07/25/2018 General - Site Plan 1. Label fire sprinkler riser room on the site plan. 2. Fire sprinkler riser room shall be accessible directly from fire lane. 3. Prelim Utility Plan - FDC requires minimum of 4-inch underground. - UNRESOLVED Parks John Elias Planning Matt Steer General - - Landscape Plan: 1- Add a tree to the end of each parking row. Three overstory trees are needed. & include three additional trees to the required and provided columns in interior landscaping. 2- Include the East Property line under minimum tree requirements within the Perimeter landscaping, 3- Note that 3 accent trees = one overstory tree for the purpose of tree calculations. 4- Recalculate the nonvehicular open space to be .15 * (124,995-32,370) = 13,894 square feet. (11.1% overall), 5- Include total required and provided row within the table for the overall landscaping. 6- Nonvehicular tree calculation to read "13,894/2,500 = 5.6" (6 trees required; 6 overstory equivalents provided). - UNRESOLVED General - - Elevations: 1. Include details of outdoor gazebo? If unknown, then please note as a condition of the PD that the Director of Community Development shall be given the authority to administratively approve the design at a later date. 2. Include details of the dumpster enclosure, generator enclosure and elecronic sign on the elevations. 3. Submit a portable color board showing all materials to be 1 of 2 PD18-07-000262Plan Case ID CITY OF COPPELL DRC REPORT Project Name Old Town Addition, Lot 1, BkgCOMMENTS used. 4. Provide a picture of the enhanced pavement to be used in the front yard. 5. The trim covers and clear glass is okay, but unfamiliar with frit pattern. When did this get added? - UNRESOLVED General - - Parking Calculations: 1. Include the S. Coppell Rd East in the parking tabulations as there are 64 spaces along that stretch of road. Phase 2 has 64 units therefore requires 160 parking spaces at 2.5 per unit. 128 are provided on site. 32 are needed for Phase II and 32 are in excess and will help in the provided on-street. 2. Include the Frost Cupcakery - Cottage 11 as retail. - UNRESOLVED General - - Site Plan: 1. Revise proposed lot coverage to 22% 2. Change the adjacent zoning of property to the east to PD-250R23-H 3. List the parking required in the Site Data Table. 4. Show the proposed sign location. 5. Change existing zoning note to read PD-250R8-H. 6. Within the PD Table, include what the ordinance requires, then list the requested exception. 7. Include the internally illuminated electronic sign design as a condition. 8. Include the gazebo design to be administratively approved at a later date by the director of Community Development as a PD Condition. - UNRESOLVED 2 of 2