Loading...
Exhibit E - Sign Package1 THE SIGNS ON THESE PAGES HAVE BEEN DESIGNED TO MEET OR EXCEED ALL APPLICABLE CODES OR REQUIREMENTS OF THE NEC-2014 AND OR THE 2014 FBC AND OR THE 2007 SFBC CDR: bb RCC: aa DPM: aa customer approval date: Designer: mh Page: THIS DESIGN IS FOR THE SOLE PURPOSE OF ILLUSTRATION & CONCEPT DESIGN. THIS FILE IS NOT TO BE USED FOR PRODUCTION AND/OR FABRICATION. THIS DESIGN IS THE SOLE PROPERTY OF HARBINGER AND MAY NOT BE USED OR DUPLICATED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF HARBINGER. SVE7128-R5 F:\Customers\7 Eleven\Art \SVE7128-R5 #1043547.cdr date:description: designer: mh mh mh mh mh mh rev. 07.11.18 07.17.18 07.26.18 08.17.18 10.03.18 10.08.18 00 R1 R2 R3 R4 R5 Original Concept Revised sign B letter height & changed to standard canopy. Revised sign A to non-illuminated, revised fuel canopy. Revised to SEI brand fuel. Revised sign A, site plan & building elevations. Revised sign A, removed window signs from exhibit. 7-Eleven #1043547 890 S. Denton Tap Road Coppell, Texas 75019 5300 Shad Road, Jacksonville, FL. 32257 • 904.268.4681 2301 Ohio Dr, Plano, TX. 32257 • 972.905.9450 RER: aa Site Plan 1” = 50'-0" B C C C A Monument SignA 48” Channel LettersB C W9 Canopy Signs Exhibit E 1 of 5 2 THE SIGNS ON THESE PAGES HAVE BEEN DESIGNED TO MEET OR EXCEED ALL APPLICABLE CODES OR REQUIREMENTS OF THE NEC-2014 AND OR THE 2014 FBC AND OR THE 2007 SFBC CDR: bb RCC: aa DPM: aa customer approval date: Designer: mh Page: THIS DESIGN IS FOR THE SOLE PURPOSE OF ILLUSTRATION & CONCEPT DESIGN. THIS FILE IS NOT TO BE USED FOR PRODUCTION AND/OR FABRICATION. THIS DESIGN IS THE SOLE PROPERTY OF HARBINGER AND MAY NOT BE USED OR DUPLICATED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF HARBINGER. SVE7128-R5 F:\Customers\7 Eleven\Art \SVE7128-R5 #1043547.cdr date:description: designer: mh mh mh mh mh mh rev. 07.11.18 07.17.18 07.26.18 08.17.18 10.03.18 10.08.18 00 R1 R2 R3 R4 R5 Original Concept Revised sign B letter height & changed to standard canopy. Revised sign A to non-illuminated, revised fuel canopy. Revised to SEI brand fuel. Revised sign A, site plan & building elevations. Revised sign A, removed window signs from exhibit. 7-Eleven #1043547 890 S. Denton Tap Road Coppell, Texas 75019 5300 Shad Road, Jacksonville, FL. 32257 • 904.268.4681 2301 Ohio Dr, Plano, TX. 32257 • 972.905.9450 RER: aa MANUFACTURE & SHIP ONE (1) M9 / L9 D/F NON-ILLUMINATED SIGN CABINET WITH REVERSE HALO-ILLUMINATED CHANNEL LOGO FORMS. 8” DEEP EXTRUDED ALUM. CABINET W/ 2” INSET HINGED RETAINERS TO BE PAINTED DURANODIC BRONZE. 2” INSET RETAINERS TO BE HINGED ON ONE SIDE OF CABINET. LOGO CHANNEL FORMS: 4” DEEP .063 ALUMINUM RETURNS & .125 ALUMINUM FACES W/ 3/16” THICK CLEAR POLYCARBONATE BACKS. FORMS PAINTED PMS 021 ORANGE, PMS 485 RED, PMS 349 GREEN. RETURNS OF FORMSS PAINTED TO MATCH FACE COLOR. “®” TO BE 3M 3630-26 GREEN VINYL APPLIED FIRST SURFACE. LETTERS TO BE REVERSE HALO ILLUMINATED W/ WHITE LEDS. LETTERS PIN MOUNTED 1” OFF ALUMINUM CABINET FACE/PANEL THAT IS PAINTED DURANODIC BRONZE & PMS WHITE. CUSTOM L9 FACES: 3/16” THICK PAN FORMED CLEAR POLYCARBONATE FACES BACK SPRAYED PMS 485 RED THEN PMS WHITE. PROPOSED WITH PWM 9” NON-ILLUMINATED SEGMENT ELECTRONIC PRICE UNITS. 3M 3630-26 GREENVINYL SPECS: DURANODIC BRONZE, PMS 021 ORANGE, PMS 485 RED, PMS 349 GREEN, PMS WHITEPAINT SPECS: NOTE: MONUMENT SIGN SHALL BE CONSTRUCTED OF THE SAME PRIMARY MASONRY MATERIALS AS THE FRONT BUILDING FACADE OR THE PRINCIPAL OR MAIN BUILDING ON THE SAME LOT OR SHALL BE STONE OR BRICK AND SHALL BE SIMILAR ARCHITECTURAL STYLE. NOTE: ALL BRICK/MASONRY TO BE PROVIDED BY GC’S SUBCONTRACTOR. Front Elevation & Side Detail - Custom Monument Sign Structure - Sign A 1/2” = 1’-0”Display Square Footage (Cabinet): 18.04’-0” (48”) OAH7”87” OAW 18 1/4” 30” CHANNEL FORM 29 5/8” PAN 31 5/8” V.O. 34 3/8” CUT SIZE 35 5/8” RETAINER 72” CABINET FACE: M9 STREET SIDE OAH: OAL: 27 1/2” 25 1/16” 7-ELEVEN LOGO DIMENSIONS: HINGE 2” INSET RETAINER PANNED 3/16” POLY. FACE 2” PAN2” PAN 8” MASONRY BASE (BY GC SUB) PWM PRICE SCROLLER PWM PRICE SCROLLER NOTE: GAS PRICE CABINET TO BE EXTERNALLY ILLUMINATED. NOTE: ALL/ANY EXTERNAL ILLUMINATION IS TO BE PROVIDED BY ELECTRICAL CONTRACTOR. NOTE: TYPE OF EXTERNAL LIGHTING IS TBD. Allowed: Proposed: 40.0 sqft 29.1 sqft Total Sign Square footage Calculations: Allowed: Proposed: 4 Feet 4 Feet Overall Height: Requirements: Proposed: 10 Feet 10 Feet SetBacks: 1. Electromagnetic technology involves changing a magnetic field so as to induce an electric current. 2. An electromagnetic field converts the mechanical energy into electrical energy. 3. PWM uses this technology for their segment signs. 4. Power is only required to change the data displayed. 5. Inherent magnetic memory in each segment retains the display indefinitely without power being applied. 6. The data on multiple displays can be quickly changed. 7. The light-reflecting segments provide excellent visibility for a wide range of ambient light conditions. 8. Visibility increases with an increase in the ambient light level. 9. Characters are visible from very wide angles. 10. Each segment rotates on a stainless steel pivot for maximum reliability. 1. Heat is a non-issue for electromagnetic signs. 2. In areas where segment signs are exposed to extreme cold, additional heating is required. Principles of Operation 1. The drawings LEFT show a rounded panel segment from the top view. 2. To set a price, meaning to adjust the segments to reflect the desired number, an electronic impulse to the coil creates a magnetic field. 3. This magnetic field turns the segment in or out. 4. Each segment moves between the background and display surface plate. PWM SEGMENT ELECTRONIC PRICE UNIT: DIESEL 30” CHANNEL FORM36” CABINET29 5/8” PAN31 5/8” V.O.34 3/8” CUT SIZE5 3/4”4 3/8”11 3/8”7 1/4”4”4”8” MASONRY BASE (BY GC SUB) 1”1” 12V 60WATT REMOTE POWER SUPPLY 1/8” ALUM. PAINTED FACE 3/16” CLEAR POLYCARBONATE WHITE LEDS .063 ALUM. RETURNS 1” STAND OFF ALUM. BACK PANEL DIESELNIGHT VIEW NIGHT VIEW 5”Exhibit E 2 of 5 3 THE SIGNS ON THESE PAGES HAVE BEEN DESIGNED TO MEET OR EXCEED ALL APPLICABLE CODES OR REQUIREMENTS OF THE NEC-2014 AND OR THE 2014 FBC AND OR THE 2007 SFBC CDR: bb RCC: aa DPM: aa customer approval date: Designer: mh Page: THIS DESIGN IS FOR THE SOLE PURPOSE OF ILLUSTRATION & CONCEPT DESIGN. THIS FILE IS NOT TO BE USED FOR PRODUCTION AND/OR FABRICATION. THIS DESIGN IS THE SOLE PROPERTY OF HARBINGER AND MAY NOT BE USED OR DUPLICATED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF HARBINGER. SVE7128-R5 F:\Customers\7 Eleven\Art \SVE7128-R5 #1043547.cdr date:description: designer: mh mh mh mh mh mh rev. 07.11.18 07.17.18 07.26.18 08.17.18 10.03.18 10.08.18 00 R1 R2 R3 R4 R5 Original Concept Revised sign B letter height & changed to standard canopy. Revised sign A to non-illuminated, revised fuel canopy. Revised to SEI brand fuel. Revised sign A, site plan & building elevations. Revised sign A, removed window signs from exhibit. 7-Eleven #1043547 890 S. Denton Tap Road Coppell, Texas 75019 5300 Shad Road, Jacksonville, FL. 32257 • 904.268.4681 2301 Ohio Dr, Plano, TX. 32257 • 972.905.9450 RER: aa 20’-5 3/4” (OAW)4’-0” OAHMANUFACTURE & SHIP ONE (1) SET OF CUSTOM 48” LETTER HEIGHT INTERNALLY ILLUMINATED REMOTE CHANNEL LETTERS. 3/16” THICK WHITE ACRYLIC FACES. 4” DEEP ALUMINUM RETURNS PRE-PAINTED 313 DURANODIC BRONZE. 1” DURANODIC BRONZE(JEWELITE) TRIM CAP. LETTERS TO BE INTERNALLY ILLUMINATED W/ WHITE LEDS. 313 DURANODIC BRONZEPAINT SPECS: NOTE: LOGOS IN ANY COLOR SHALL NOT EXCEED 20% OF THE AREA OF THE SIGN. Front View & Side Mounting Detail - Custom 48” Letter Height - Internally Illuminated Remote Channel Letters - Sign B 3/8” = 1'-0"Display Square Footage: 87.5 4” .040 ALUM. RETURNS 12V 60WATT REMOTE POWER SUPPLY 3MM ACM WHITE BACKS 3/16” WHITE POLY FACE 1” JEWELITE TRIM CAP WHITE LEDS BUILDING WALL 3/8” ALL THREAD W/ NUTS & WASHER ½” SEALTITE CONDUIT 1/4” WEEP HOLES DISCONNECT SWITCH DISCONNECT SWITCH (INSIDE WALL)Exhibit E 3 of 5 4 THE SIGNS ON THESE PAGES HAVE BEEN DESIGNED TO MEET OR EXCEED ALL APPLICABLE CODES OR REQUIREMENTS OF THE NEC-2014 AND OR THE 2014 FBC AND OR THE 2007 SFBC CDR: bb RCC: aa DPM: aa customer approval date: Designer: mh Page: THIS DESIGN IS FOR THE SOLE PURPOSE OF ILLUSTRATION & CONCEPT DESIGN. THIS FILE IS NOT TO BE USED FOR PRODUCTION AND/OR FABRICATION. THIS DESIGN IS THE SOLE PROPERTY OF HARBINGER AND MAY NOT BE USED OR DUPLICATED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF HARBINGER. SVE7128-R5 F:\Customers\7 Eleven\Art \SVE7128-R5 #1043547.cdr date:description: designer: mh mh mh mh mh mh rev. 07.11.18 07.17.18 07.26.18 08.17.18 10.03.18 10.08.18 00 R1 R2 R3 R4 R5 Original Concept Revised sign B letter height & changed to standard canopy. Revised sign A to non-illuminated, revised fuel canopy. Revised to SEI brand fuel. Revised sign A, site plan & building elevations. Revised sign A, removed window signs from exhibit. 7-Eleven #1043547 890 S. Denton Tap Road Coppell, Texas 75019 5300 Shad Road, Jacksonville, FL. 32257 • 904.268.4681 2301 Ohio Dr, Plano, TX. 32257 • 972.905.9450 RER: aa 90.17’ BUILDING WIDTH 11.11’11.11’ Storefront & Side Corner Elevation - Sign B 3/32”=1’-0” Square footage Calculations: Allowed: Proposed: 90.0 sqft 87.5 sqft Exhibit E 4 of 5 5 THE SIGNS ON THESE PAGES HAVE BEEN DESIGNED TO MEET OR EXCEED ALL APPLICABLE CODES OR REQUIREMENTS OF THE NEC-2014 AND OR THE 2014 FBC AND OR THE 2007 SFBC CDR: bb RCC: aa DPM: aa customer approval date: Designer: mh Page: THIS DESIGN IS FOR THE SOLE PURPOSE OF ILLUSTRATION & CONCEPT DESIGN. THIS FILE IS NOT TO BE USED FOR PRODUCTION AND/OR FABRICATION. THIS DESIGN IS THE SOLE PROPERTY OF HARBINGER AND MAY NOT BE USED OR DUPLICATED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF HARBINGER. SVE7128-R5 F:\Customers\7 Eleven\Art \SVE7128-R5 #1043547.cdr date:description: designer: mh mh mh mh mh mh rev. 07.11.18 07.17.18 07.26.18 08.17.18 10.03.18 10.08.18 00 R1 R2 R3 R4 R5 Original Concept Revised sign B letter height & changed to standard canopy. Revised sign A to non-illuminated, revised fuel canopy. Revised to SEI brand fuel. Revised sign A, site plan & building elevations. Revised sign A, removed window signs from exhibit. 7-Eleven #1043547 890 S. Denton Tap Road Coppell, Texas 75019 5300 Shad Road, Jacksonville, FL. 32257 • 904.268.4681 2301 Ohio Dr, Plano, TX. 32257 • 972.905.9450 RER: aa VARIES 36" 24"36" Front Elevation - 36" Canopy Height - Sign And Graphics Layout 3/8” = 1’-0” Face & Side Detail - W9 (00000000) Canopy Sign Cabinet - Sign C ½” = 1’-0"Display Square Footage(Cabinet): 9.0 MANUFACTURE & SHIP THREE (3) W9 (00000000) S/F INTERNALLY ILLUMINATED CANOPY SIGN CABINETS. 3/16” THICK PAN FORMED & EMBOSSED WHITE ACRYLIC FACE W/ TRANSLUCENT VINYL GRAPHICS APPLIED FIRST SURFACE. 4” DEEP EXTRUDED ALUM. CABINET W/ 1 1/4” RETAINERS TO BE PAINTED WHITE. CABINET TO BE INTERNALLY ILLUMINATED W/ WHITE LEDS. VINYL SPECS: 3M 3630-44 ORANGE, 3M 3630-33 RED, 3M 3630-26 GREEN PMS WHITEPAINT SPECS: NOTE: SIGN TO BE INSTALLED 2’-0” FROM LEFT EDGE OF GAS CANOPY. OAH: OAL: 29 1/2” 27” 7-ELEVEN LOGO DIMENSIONS: PANNED 3/16” ACRYLIC FACE ON/OFF TOGGLE SWITCH LAG BOLTS W/ SHIELDS WHITE LED GAS CANOPY 4”2” PAN 1/4” EMBOSS EMBOSS 3/4” EMBOSS .040 ALUM. BACK POWER SUPPLY 1 1/4” RETAINER 36” CABINET 35 1/2” CUT SIZE 33 1/2” V.O. 30 1/2” PAN 36” CABINET35 3/4” CUT SIZE33 1/2” V.O.31 1/2” PAN2 1/4” FLANGE 2” FLANGE Front and Side Elevation (6MPD Stacked Canopy Configuration) - Sign C NTS 17’-6” OAH3’-0”14’-6”86’-0” 2’-0”3’-0” 36’-0” 2’-0”3’-0” FRONT ELEVATION: SIDE ELEVATION: SIDE ELEVATION: NOTE: PER CITY CODE TRI-STRIPES ARE NOT ALLOWED.17’-6” OAH3’-0”14’-6”REAR ELEVATION: Exhibit E 5 of 5