No comments on concept plans. Insufficient detail for
technical review of proposed building.
Kent Collins
08/31/2018
1. A TIA will be required to determine if a right -turn decel lane
will be needed to provide safe access to the development
2. Fire hydrants are required on 300' spacing
3. Additional comments will be provided upon receipt of
detailed engineering plans.
Tim Oates
08/30/2018
1. Fire lanes required to have turning radii of 30ft inside and
54ft outside.
2. FDC to be located adjacent to a fire hydrant.
3. FDC line to be 4 -inch in accordance with engineering detail
4. Fire hydrants to be spaced at 300 -ft intervals
John Elias
08/29/2018
No comments
Marcie Diamond
08/31/2018
Site Plan
1. Should the Fire Lane encircle the building, if so, are the
radii ok?
2. Add dimensions of the building, and square footage of
footprint.
3. Maximum of 15 spaces in a row are permitted w/out a
landscape island, there are 16 spaces along the east property
line.
4. Correct the spelling of Proposed in the Site Summary
5. Add note:
Requesting Variance to Sec. 12-30-18.(2) - Hotel and
residence hotel, c. Not more than 22 room units per acre. All
other requirements of this Section are being met or exceeded.
1 of 2
Landscape Plan
1. Adjust locations of proposed trees along the southern
property line so not to conflict with trees proposed for the TRU
Hotel.
2. Delete the pool and deck area from the Open Space area
calculations, but you can add the additional 10 feet shown
along the north property line (perimeter) to the non -vehicular
area.
First Floor Plan — replace words with table similar to the
attached.
Signage
1. Please provide additional calculations and measurements
to — compliance with or variances to the following provision of
the sign ordnance:
"A. Attached signs located at a height above 36 feet shall be
permitted an increase in maximum effective area. Such
increase shall not exceed four square feet of effective area for
T H £ • C 1 T Y • 0 F
COPPELL
9 g 1
CITY OF COPPELL
DRC REPORT
T H £ • C i T Y • 0 F
COPPELL
T *�' o *
E k A g t a g
Plan Case ID PD18-08-000270 COMMENTS Project Name Duke Lesley, Lot , BkC
each additional one foot of height above 36 feet measured
from the base of the sign. Such signs may be increased to a
maximum effective area of 400 square feet'.
It appears that the building frontage measures approximately
315 feet, which would permit 315 square feet of total signage,
however, signs above 36 feet may be increased in effective
area 4 feet for each additional foot above 36 feet. Therefore,
provide:
• The total effective area of each sign.
• The height of the base of the sign
2. The Monument Sign must be externally lit (or halo lit), have a
masonry base.