Loading...
DRC Comments JanuaryPD18-08-000269 Plan Case ID CITY OF COPPELL DRC REPORT Project Name Prologis , Lot 3 , 2R, BkBCOMMENTS 455 N FREEPORT PKWY Address Marcie Diamond Case Manager 12/17/2018 Application Complete Date Planned Development - Conceptual PD Plan Type / Workclass PD-295-HC Archway 121 Project Description Agency Reviewed By Review Date Plan Review Details Building Suzanne Arnold 12/20/2018 No comment Engineering Kumar Gali 12/27/2018 1. Develop a traffic impact analysis for the full buildout of the site 2. Provide a clearer utility plan with unique line types for each utility. The current plan has the same line types and harder to identify the connections to existing. Number the connections to the existing water mains and sewers. Consider removing non-utility line types 3. Show water main connection in the proposed QT site plan 4. Right turn radius into the property from Freeport Parkway should be a maximum of 30 radius 5. Additional comments will be provided upon receipt of detailed engineering plans Fire Tim Oates 12/27/2018 Overall: 1. Name of the street is Northwestern. 2. Fire lane at the NW area of site plan does not appear to function - provide turn template exhibit. 3. Fire lane radii are 30-ft inside, 54-ft outside. 4. Show proposed fire hydrants and FDC's on site plan. 5. Water lines (fire hydrants) and fire lanes are required to be installed prior to QT construction. Fire lane off SH121 will be required. 6. Fire hydrants required every 300lf along fire lane easement. Detail QT site: 1. Buildings over 5,000sf are required to be equipped with an automatic fire sprinkler system - canopy square footage is considered building if Type V construction type is used. 2. Fire lane shall be entire width of driveways, then 24ft at first drive aisle. 3. Fire hydrant being relocated at the driveway off N Freeport - where? 4. Fuel tank vents shall be incorporated into the canopy, not freestanding. Parks John Elias 12/27/2018 A tree removal permit will be required prior the removal of any trees from the property. Planning Marcie Diamond 12/20/2018 A. REVISE CONCEPT SITE PLAN, LANDSCAPE PLAN AND TREE SURVEY TO HAVE THE SAME SCALE AND ORIENTATION – IT WOULD BE ALSO HELPFUL TO HAVE THE QT PLANS ORIENTED IN A SIMILAR MANNER. B. Provide a detail list of the revisions that were made to this submittal to address the P&Z and Staff Comments. C. Staff cannot support the variances for P&Z Detail Site Plan approval as the specified purpose of requiring SUP’s for drive through restaurants, gas stations and hotels is to allow City Council, after recommendation by the Planning and Zoning 1 of 4 PD18-08-000269 Plan Case ID CITY OF COPPELL DRC REPORT Project Name Prologis , Lot 3 , 2R, BkBCOMMENTS Commission, to determine the appropriateness of the use, its character and impact on surrounding properties. Concept Site Plan 1. Add a detail list of requested variances to the Zoning Ordinance, the HC District regulations and the Landscape Ordinance 2. Delete the notes referring to P&Z approval of Detail Plan. 3. All fire lanes need to be labeled fire lane and mutual access easements. 4. Include the phasing of development to ensure the entire fire lane serving this tract is built with this lot. 5. Where are the monument signs proposed to be located – if they are the unlabeled crescent shaped elements on the plan, then the would require several variances to the Sign Ordinance in terms of number of signs, placement and size, etc. 6. Need additional detail on the patio/decorative paving area, if this is an amenity, why is the reduction in the landscape buffer between Tracts B and D being requested? 7. Loading Areas (minimum of 12 by 30 feet) will be required for the multi-tenant building, the hotel as well as the office building 8. Tract C - Need additional detail on the proposed 4 story office – does that include at grade, below or above grade structured parking? Note # of parking spaces that are structured and unstructured. a. Include the maximum height of the building. 9. Tract D – Hotel – this will require SUP or PD amendment to be approved by City Council. a. What is the proposed square footage.. 12,000 or 14, 333 square feet? 10. HC District and Freeway Special District Land Use Designation encourages a greater setback (30-50 feet) along these major thoroughfares. Exhibits L2, L-3 and L-4 - Landscape Plan and Tables 1. Re-orient and re-scale the Landscape Plan to match the Concept Site Plan. 2. Some variations to the amount of landscaping per lot could potentially be justified if compensated with overall design and amenity package and the minimum of 30% of each lot to be landscaped areas is achieved. As presented, it is not acceptable. a. Note that the non-vehicular calculation is net of the provided perimeter and interior landscaped areas. b. Perimeter landscaping is required along all interior lot lines but may be relocated internal to the site (including required number of trees) where mutual access/driveways are along the lot lines. 3. Need additional detail on the patio/decorative paving area, if this is an amenity, why is the reduction in the landscape buffer between Tracts B and D being requested? 4. At this Concept Plan stage, and an accurate accounting of the areas designated as landscaping (both soft and hardscape) as well as quantity and size of landscape materials (overstory trees, ground cover and shrubs) is more 2 of 4 PD18-08-000269 Plan Case ID CITY OF COPPELL DRC REPORT Project Name Prologis , Lot 3 , 2R, BkBCOMMENTS pertinent than specific plant material types. a. Provide a color exhibit indicating on each lot which areas are being designated as perimeter, parking lot and non-vehicular landscaping Exhibit C3 - Tree survey 1. Is there any opportunity to preserve any of the trees, such as the 22’ pecan along SH121? Monument Sign Exhibit 1. Remove the City of Coppell as the developer/owner 2. Where are the monument signs proposed to be located? – if they are the unlabeled crescent shaped elements on the Concept plan, then the would require several variances to the Sign Ordinance in terms of number, placement and size, etc. 3. Need additional detail as to size, materials, colors, illumination etc. Concept Elevations 1. The coherence in architectural design between the QT and the remainder of the property is not immediately apparent with this submittal.. attention needs to be paid to brick color (color board would be helpful) and design details like cornices, metal accents (with and without stripes), store front color/materials, etc. 2. Will there be standards for attached signs to be consistent architectural theme while permitting branding/logos of the individual tenants? Are the QT attached signs setting the standard for this development? 3. Will the proposed hotel incorporate any or all of these architectural features? Brick color? Etc. Detail Site Plan for QT 1. The building size is different on this sheet as the concept plan, which is correct? 2. Delete the note about SUP. 3. The proposed zoning is PD-295-HC – not amended 4. Add a note that this property will be in compliance with Outside Storage and Display – Retail Stores and Shops in Article 42 – Special Definitions of the Zoning Ordinance which prohibits outside storage and display under canopies and awnings, and only permits outside storage when visually screened with a solid wall will be adhered to. 5. Two monument signs are being proposed, only one 40 -square foot sign is permitted. 6. Fire Lanes need to be labeled Fire Lanes and Mutual Access Easements 7. Include phasing plan for the paving. Landscape Plan 1. All landscape islands need to be a minimum of 150 square feet. 2. Include in Landscape Requirement Table specific square footage of provided area – “Provided as shown” is not acceptable. 3. Perimeter trees are required along all property lines where buffers are being provided. 3 of 4 PD18-08-000269 Plan Case ID CITY OF COPPELL DRC REPORT Project Name Prologis , Lot 3 , 2R, BkBCOMMENTS 4. Add dimensions to landscape buffers Building elevations 1. It appears that these color elevations are the same as the previous except for the deletion of two 20 sq. ft. QT logos and the addition of large, full color (temporary poster?) signs on right and left elevations (that would not be permitted). 2. Signage and awning color and materials do not comply with Zoning Ordinance. a. Provide specific calculations on permitted, requested and variances to the Sign Ordinance. 3. The gasoline canopy elevations were not resubmitted - are three - 20 sf. ft. button signs on the gas canopy and/or other signage being requested? 4. Proposed brick wall? 3’ tall? If desired, will need to be color, materials, height, etc. specified on the site and landscape plans, including dimensions from R.O.W. to ensure no conflict with the sight visibility triangle at driveway. 4 of 4