AstraZeneca Parking Expansion.ADM APP1567912131415171816192021222324343332312521011262728293034835373836504039414246454447484349TREE MITIGATION FENCE, TYP.REF DETAIL 1 & 2 SHEET L1.130' DRAINAGE & UTILITY EASEMENTBUILDINGWRANGLER DRIVEPROPERTY LINE / LIMIT OF WORKPROPERTY LINE / LIMIT OF WORK24' FIRELANE & UTILITY EASEMENTLIMIT OF WORKLOT 4, BLOCK 8PARK WEST COMMERCE CENTERINST.NO.201400014948D.R.D.C.TARTIFICIAL LOT LINE24' FIRE LANE & UTILITY EASEMENT50' LONE STAR GAS COMPANY EASEMENTLIMIT OF WORKPROPERTY LINENOTE: ALL PROTECTED TREES ON SITENOT REMOVED SHALL BE PRESERVED.24' FIRE LANE & UTILITY EASEMENT10' GAS EASEMENT10' ELECTRIC EASEMENT24' FIRELANE & UTILITY EASEMENT24' FIRELANE & UTILITY EASEMENT15' WATER EASEMENTTREE TO REMAINTREE TO BE REMOVEDTREE PROTECTION FENCETREE PRESERVATION LEGENDNOTESDRAWNDESIGN DATE SCALEFILE NO.DATENO.REVISIONCITY OF COPPELL, DALLS COUNTY, TEXASDATENO. ISSUEPARK WEST COMMERCE CENTERLOT 3R, BLOCK 8ASTRAZENECA PARKING EXPANSIONASTRAZENECA PARKING EXPANSIONAPESDNAACERDLR XTEFOGERIATS TEASET TCCETSIHHARMAN 3146ANNE M.OWNER:FLUOR ENTERPRISES INC.100 FLUOR DANIEL DRIVEGREENSVILLE, SC 29607LANDSCAPE ARCHITECT:ANNE HARMANAHARMAN @PKCE.COMPACHECO KOCH CONSULTING ENGINEERS7557 RAMBLER ROAD, SUITE 1400DALLAS TEXAS 75231972-235-3031L1.0TREE MITIGATION PLAN1TREE MITIGATION PLAN1" = 40'-0"
1.A. PROCEDURES REQUIRED PRIOR TO CONSTRUCTION: THE FOLLOWING PROCEDURESSHALL BE FOLLOWED ON ALL TYPES OF CONSTRUCTION PROJECTS.A. DURING PRE-CONSTRUCTION, TREES TO BE REMOVED SHOULD BE REMOVEDFROM THE SITE IN A MANNER TO AVOID INJURY TO REMAINING TREES,INCLUDING THE REMOVAL OF STUMPS AND/OR ROOT SYSTEMS. HEAVYEQUIPMENT SHALL NOT ENCROACH ON THE ROOT SYSTEMS OF TREES TO BERETAINED OR OTHER TREES OF HIGH VALUE. IF NECESSARY, TREES SHOULD BEREMOVED MANUALLY WITH CHAIN SAWS, AND STUMPS SHOULD BE GROUNDOUT INSTEAD OF USING HEAVY EQUIPMENT.B. CRITICAL ROOT ZONES SHALL BE ESTABLISHED AND MAINTAINED FOR ALL TREESTO BE CONSERVED ON A CONSTRUCTION SITE. THIS AREA MAY BE ADJUSTED FOREXISTING BUILDINGS, WALKWAYS, AND ROADS BY PERMISSION OF OWNER.BARRICADES SHALL BE 4 FOOT HIGH ORANGE VINYL CONSTRUCTION FENCE ORCHAINLINK FENCE. SIGNS, IN ENGLISH AND SPANISH SHALL BE PLACED VISIBLEFROM ALL DIRECTIONS, ALONG THE FENCE TO INFORM WORKERS OF THE PURPOSEOF THE BOUNDARY. THE BARRIER AND PROPER SIGNAGE SHALL BE INSTALLEDPRIOR TO ANY SITE PREPARATION AND SHALL BE MAINTAINED THROUGHOUT ALLPHASES OF THE CONSTRUCTION PROJECT. EROSION AND SEDIMENT CONTROLBARRIERS SHALL BE INSTALLED OR MAINTAINED IN A MANNER WHICH DOES NOTRESULT IN SOIL BUILDUP WITHIN THE TREE DRIP LINE. APPLY 4 INCHES OF COURSEMULCH WITHIN PROTECTION AREAS TO HELP REDUCE MOISTURE STRESS ANDREDUCE MAINTENANCE.C. WHERE EXCAVATIONS ARE PERFORMED WITHIN THE ROOT ZONE OF TREES,TRENCHING SHOULD BE PERFORMED MANUALLY, OR BY USING A VIBRATORYPLOW, DIRECTIONAL BORER, OR BY AIR SPADING. BACKHOES SHALL NOT BEUSED TO RIP ROOTS AT CONSIDERABLE DISTANCES FROM THE POINT OFEXCAVATION.¬WHEN TRENCHING OR MODIFICATION OF THE ROOT ZONEENCROACHES HEAVILY ONTO ESTABLISHED TREES, A ROOT PRUNING METHODSHOULD BE EMPLOYED WHERE THE ROOTS ARE EXPOSED AND TRIMMED WITHPROPER PRUNING TOOLS SEVERAL INCHES TO THE SIDE OF THE TRENCHBORDERING THE TRUNK OF THE AFFECTED TREE. TEARING OF ROOTS IS TO BEAVOIDED. SUPPLEMENTAL IRRIGATION SHALL START IF NEEDED. ANY ROOTSEXPOSED BY CONSTRUCTION ACTIVITY SHALL BE PRUNED FLUSH TO THE SOILAND SEALED USING LAC BALSAM.¬BACKFILL ROOT AREAS WITH GOOD QUALITYTOP SOIL AS SOON AS POSSIBLE (I.E. WITHIN THE SAME WORKDAY). IF ROOTSARE NOT BACKFILLED WITHIN THIS TIME, THEY SHALL BE COVERED WITHORGANIC MATERIAL SUCH AS COMPOSTED MULCH TO A DEPTH OF 4 INCHES,WHICH WILL REDUCE TEMPERATURE AND MINIMIZE WATER LOSS DUE TOEVAPORATION.¬3. THE FOLLOWING ACTIVITIES ARE PROHIBITED WITHIN THE LIMITS OF THE CRITICAL ROOTZONE OF ANY PROTECTED TREE SUBJECT TO THE REQUIREMENTS OF THE CITY ORDINANCE.A. MATERIAL STORAGE: NO MATERIALS INTENDED FOR USE IN CONSTRUCTION OR WASTEMATERIALS ACCUMULATED DUE TO EXCAVATION OR DEMOLITION SHALL BE PLACEDWITHIN THE LIMITS OF THE CRITICAL ROOT ZONE OF ANY PROTECTED TREE.B. EQUIPMENT CLEANING/LIQUID DISPOSAL: NO EQUIPMENT SHALL BE CLEANED OR OTHERLIQUIDS DEPOSITED OR ALLOWED TO FLOW OVERLAND WITHIN THE LIMITS OF THECRITICAL ROOT ZONE OF A PROTECTED TREE. THIS INCLUDES, WITHOUT LIMITATION,PAINT, OIL, SOLVENTS, ASPHALT, CONCRETE, MORTAR OR SIMILAR MATERIALS.C. TREE ATTACHMENTS: NO SIGNS, WIRES OR OTHER ATTACHMENTS, OTHER THAN THOSE APROTECTIVE NATURE, SHALL BE ATTACHED TO ANY PROTECTED TREE.D. VEHICULAR TRAFFIC: NO VEHICULAR AND/OR CONSTRUCTION EQUIPMENT TRAFFIC ORPARKING SHALL TAKE PLACE WITHIN THE LIMITS OF THE CRITICAL ROOT ZONE OF ANYPROTECTED TREE OTHER THAN ON EXISTING STREET PAVEMENT. THIS RESTRICTION DOESNOT APPLY TO SINGLE INCIDENT ACCESS WITHIN THE CRITICAL ROOT ZONE FORPURPOSES OF CLEARING UNDERBRUSH, ESTABLISHING THE BUILDING PAD ANDASSOCIATED LOT GRADING, VEHICULAR TRAFFIC NECESSARY FOR ROUTINE UTILITYMAINTENANCE, EMERGENCY RESTORATION OF UTILITY SERVICE, OR ROUTINE MOWINGOPERATIONS.E. GRADE CHANGES: NO GRADE CHANGES SHALL BE ALLOWED WITHIN THE LIMITS OF THECRITICAL ROOT ZONE OF ANY PROTECTED TREE UNLESS ADEQUATE CONSTRUCTIONMETHODS ARE APPROVED BY THE LANDSCAPE ARCHITECT.F. IMPERVIOUS PAVING: NO PAVING WITH ASPHALT, CONCRETE OR OTHER IMPERVIOUSMATERIALS THAT MAY REASONABLY BE EXPECTED TO KILL A TREE SHALL BE PLACEDWITHIN THE LIMITS OF CRITICAL ROOT ZONE OF A PROTECTED TREE EXCEPT ASOTHERWISE ALLOWED IN THE CITY ORDINANCE.4. PROHIBITED ACTIVITIES IN DRIP-LINE: NO HEAVY EQUIPMENT, INCLUDING BUT NOT LIMITEDTO TRUCKS, TRACTORS, TRAILERS, BULLDOZERS, BOBCAT TRACTORS, TRENCHERS,COMPRESSORS, AND HOISTS, SHALL BE ALLOWED INSIDE THE DRIP-LINE OF ANY PROTECTEDTREE ON ANY CONSTRUCTION SITE WITHOUT THE SPECIFIC APPROVAL OF THE LANDSCAPEARCHITECT.5. TREES THAT WERE PREVIOUSLY IRRIGATED SHALL BE IRRIGATED DURING CONSTRUCTION.THEY SHALL RECEIVE A MIN. OF ONE INCH OF WATER PER WEEK FROM THE COMBINATION OFRAINFALL AND IRRIGATION. TREES WITH ROOT-DAMAGE SHALL RECEIVE TWO INCHES OFWATER PER WEEK FROM COMBINATION OF RAINFALL AND IRRIGATION.6. CONTRACTOR RESPONSIBLE FOR ANY DAMAGE TO TREES THAT ARE TO REMAIN.CONTRACTOR TO INSTALL NEW TREE OF EQUIVALENT SIZE IF DAMAGED DURINGCONSTRUCTION.TREE MITIGATION NOTESNOTESDRAWNDESIGN DATE SCALEFILE NO.DATENO.REVISIONCITY OF COPPELL, DALLS COUNTY, TEXASDATENO. ISSUEPARK WEST COMMERCE CENTERLOT 3R, BLOCK 8ASTRAZENECA PARKING EXPANSIONASTRAZENECA PARKING EXPANSIONAPESDNAACERDLR XTEFOGERIATS TEASET TCCETSIHHARMAN 3146ANNE M.OWNER:FLUOR ENTERPRISES INC.100 FLUOR DANIEL DRIVEGREENSVILLE, SC 29607LANDSCAPE ARCHITECT:ANNE HARMANAHARMAN @PKCE.COMPACHECO KOCH CONSULTING ENGINEERS7557 RAMBLER ROAD, SUITE 1400DALLAS TEXAS 75231972-235-3031L1.1TREE MITIGATION DATAPROTECTED TREE TOREMAINORANGECONSTRUCTION FENCEMETAL T-POST (DIRECTBURIED 24" MIN)LIMITS OF DRIP-LINE4'-0" MIN.TREE PROTECTION FENCING3/4" = 1'-0"1MINIMUM LIMITS OFCRITICAL ROOT ZONERADIUS = 1 FT. PER INCHOF TRUNK DIAMETERCRITICAL ROOT ZONEDRIPLINE OF TREETREE PROTECTION FENCING;RE: 1/L1.1EXISTING TREE TO REMAINNOTE: TREE PROTECTION FENCING SHALL BEPLACED AT OR BEYOND THE DRIP LINE ORCRITICAL ROOT ZONE, WHICHEVER ISGREATER.6'-8' O.C.TYPTREE PROTECTION FENCING - PLAN VIEW N.T.S2
13'-4"66TA66TA66TA15,449 sfCDCD6,094 sf66TA2UC66TA2UCUC2TA386STEEL EDGINGTYP.782'-0"'437'-11"'437'-11"'782'-0"'PROPOSED FENCE,REF. CIVIL782'-0"'PROPOSED SIDEWALKREF. CIVIL DWGSPROPOSED SIDEWALK REF.CIVIL DWGS.799 sfCD13'-1"'CD119 sf1UC267TA410TA312IB34'-10"'MIN. SOD LIMITS, ANYDISTURBANCE BEYOND TO BESODDED BY CONTRACTOR1,159 sfCD5QV5UC7QV3UCSTEEL EDGINGTYP.STEEL EDGINGTYP.STEEL EDGINGTYP.STEEL EDGINGTYP.WRANGLER DRIVEPROPERTY LINE / LIMIT OF WORKPROPERTY LINE / LIMIT OF WORKARTIFICIAL LOT LINELIMIT OF WORKLIMIT OF WORKLOT 4, BLOCK 8PARK WESTCOMMERCE CENTERINST.NO.201400014948D.R.D.C.TPROPERTY LINEBUILDING30' DRAINAGE & UTILITY EASEMENT24' FIRELANE & UTILITY EASEMENT24' FIRE LANE & UTILITY EASEMENT50' LONE STAR GAS COMPANY EASEMENT24' FIRE LANE & UTILITY EASEMENT10' GAS EASEMENT10' ELECTRIC EASEMENT24' FIRELANE & UTILITY EASEMENT24' FIRELANE & UTILITY EASEMENT15' WATER EASEMENTTREESQTYBOTANICAL NAMESIZE/COND.REMARKSQV 12 QUERCUS VIRGINIANA 65 GAL 3" CAL. SINGLE, STRAIGHTSOUTHERN LIVE OAK LEADER, MATCHINGUC 15 ULMUS CRASSIFOLIA 65 GAL 3" CAL. MATCHED, WELLCEDAR ELM BRANCHED, STRONG CENTRALLEADERSHRUBSQTYBOTANICAL NAMESIZESPACINGREMARKSIB 312 ILEX CORNUTA `BURFORDII` 7 GAL 36" o.c. FULL, MATCHINGBURFORD CHINESE HOLLYGROUND COVERSQTYBOTANICAL NAMESIZESPACINGREMARKSTA 1,393 TRACHELOSPERMUM ASIATICUM 4"POT 18" o.c. FULL, MATCHINGASIAN JASMINESOD/SEEDQTYBOTANICAL NAMESIZESPACINGREMARKSCD 23,619 SF CYNODON DACTYLON SOD SOLID, ROLLED TIGHT, SANDBERMUDA GRASS FILLED JOINTS, 100% WEED,PEST AND DISEASE FREE2018-05-16 14:16PLANT SCHEDULESTEEL EDGING REF. DETAIL 5/L2.11. ALL PLANTS SHALL BE SET OUT FOR APPROVAL BY THE OWNER'SREPRESENTATIVE PRIOR TO INSTALLATION.2. FINE GRADING SHALL BE PERFORMED IN ALL AREAS TO BELANDSCAPED. FINE GRADING SHALL INCLUDE THE REMOVAL OF DEBRIS,ROCKS, ETC. FROM THE SITE AND INSURE POSITIVE DRAINAGE IN ALLAREAS.3. THE CONTRACTOR SHALL LOCATE ALL UTILITIES AND EASEMENTS IN THEFIELD PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR ISRESPONSIBLE FOR ANY DAMAGE TO UTILITIES DURING THE COURSE OFCONSTRUCTION.4. WRITTEN DIMENSIONS SHALL GOVERN OVER SCALED DIMENSIONS.5. IT IS PREFERABLE THAT NO TREE BE STAKED. HOWEVER, CONDITIONSAND PLANT MATERIAL SIZE MAY NECESSITATE STAKING. THE OWNER'SREP SHALL DETERMINE IF SUPPORT IS NEEDED AND SHALL DIRECT THECONTRACTOR ACCORDINGLY.6. THE CONTRACTOR SHALL REFER TO THE SPECIFICATIONS FORADDITIONAL INFORMATION AND REQUIREMENTS ASSOCIATED WITH THELANDSCAPE AND ACCESSORIES.7. ALL PLANT MATERIALS SHALL MEET ANSI Z60.1 STANDARDS FORCALIPER, HEIGHT AND ROOT BALL SIZE. ANY MATERIALS THAT DO NOTMEET OR EXCEED SUCH STANDARDS SHALL BE REJECTED ANDREPLACED AT THE CONTRACTOR'S EXPENSE.8. BALLED AND BURLAPPED TREES SHALL HAVE THE TOP HALF OF THEWIRE BASKET REMOVED. THE BURLAP SHALL BE REMOVED TO THEGREATEST EXTENT POSSIBLE, USING A KNIFE TO CUT AND REMOVE THEBOTTOM HALF UNDER THE WIRE BASKET THAT REMAINS.9. QUANTITIES ARE SHOWN FOR CONVENIENCE ONLY. CONTRACTOR ISRESPONSIBLE FOR VERIFYING ALL QUANTITIES10. ALL LANDSCAPED AREAS SHALL BE FULLY IRRIGATED AND ANIRRIGATION PLAN WILL BE REQUIRED WITH BUILDING PERMITPLANTING GENERAL NOTESNOTESDRAWNDESIGN DATE SCALEFILE NO.DATENO.REVISIONCITY OF COPPELL, DALLS COUNTY, TEXASDATENO. ISSUEPARK WEST COMMERCE CENTERLOT 3R, BLOCK 8ASTRAZENECA PARKING EXPANSIONASTRAZENECA PARKING EXPANSIONAPESDNAACERDLR XTEFOGERIATS TEASET TCCETSIHHARMAN 3146ANNE M.OWNER:FLUOR ENTERPRISES INC.100 FLUOR DANIEL DRIVEGREENSVILLE, SC 29607LANDSCAPE ARCHITECT:ANNE HARMANAHARMAN @PKCE.COMPACHECO KOCH CONSULTING ENGINEERS7557 RAMBLER ROAD, SUITE 1400DALLAS TEXAS 75231972-235-3031L2.0LANDSCAPE PLAN1LANDSCAPE PLAN1" = 40'-0"
NOTESDRAWNDESIGN DATE SCALEFILE NO.DATENO.REVISIONCITY OF COPPELL, DALLS COUNTY, TEXASDATENO. ISSUEPARK WEST COMMERCE CENTERLOT 3R, BLOCK 8ASTRAZENECA PARKING EXPANSIONASTRAZENECA PARKING EXPANSIONAPESDNAACERDLR XTEFOGERIATS TEASET TCCETSIHHARMAN 3146ANNE M.OWNER:FLUOR ENTERPRISES INC.100 FLUOR DANIEL DRIVEGREENSVILLE, SC 29607LANDSCAPE ARCHITECT:ANNE HARMANAHARMAN @PKCE.COMPACHECO KOCH CONSULTING ENGINEERS7557 RAMBLER ROAD, SUITE 1400DALLAS TEXAS 75231972-235-3031L2.1PLANTING DETAILSNOTE: UNLESS OTHERWISE SPECIFIED, OR REQUIRED BY OWNERTREES 3" CAL, AND UNDER SHALL NOT BE STAKED.CANOPY TREE W/ NO STAKES3/4" = 1'-0"EDGE OF ROOTBALLMULCH WITHINCONTAINMENTSTAKES, IF REQUIRED(SEE GENERAL NOTES)EDGE OF HOLESET TREE PLUMBLEAVE TRUNK FLAREEXPOSED, SET ROOTBALL 2" ABOVEFINISHED GRADE,REMOVE ALLSYNTHETIC MATERIALFROM ROOTBALL3" SHREDDED MULCHMATERIALBACKFILL WITH SOILFROM TREE PITEXCAVATION, TAMPLIGHTLY & WATER IN6" LIFTS, ADDAMENDMENTS ASSPECIFIEDTREE PIT MINIMUM 2XWIDTH OF ROOT BALLSCARIFY EDGESTAMPED MOUNDUNDISTURBED SOIL1SPACING PERPLAN ORPLANT SCHEDULE3"6"PLANTING SOIL IN SHRUB BEDS:1. EXCAVATE EXISTING SOILS 4" BELOWADJACENT CURB OR SIDEWALK2. ADD 3" COMPOST & TILL INTO 6" EXISTINGSOILS, CREATING 6" PLANTING SOIL3. ADD 3" MULCH AFTER PLANTINGSHREDDED BARKMULCH LAYERTYP. SHRUB PLANTING1" = 1'-0"SHRUB PERPLANTING PLAN2TURF AND SOIL PROFILE1 1/2" = 1'-0"TURF, REF. PLANTING PLANSFOR TYPE1"6"EXISTING SOILTOPSOIL PREP (BY OTHERS):SAMPLE STRIPPED TOP SOIL AS SPECIFIED.1. ADD FERTILIZER IN THE RECOMMENDED DOSES ON THE SURFACE, THEN TILL TO 6" DEPTH2. INSTALL TURF, REF. PLANTING PLANS FOR TYPE3NOTE: STEEL EDGE SHALL CREATEA CLEAN SEPARATION BETWEENAREAS & SHALL CREATE SMOOTH,EVEN LINES (AS INDICATED ONTHE PLANS)STEEL EDGING AT PLANTING1 1/2" = 1'-0"BARK MULCHPREPARED SOIL INPLANTING AREASTOPSOIL316" x 4" STEEL EDGING (BLACK),LOCATED ON PLANTER BED SIDE,TACK WELD CORNERS AND JOINTS,SPOT SPRAY PAINT WHERE NEEDEDWITH BLACK ENAMELTOP OF SOD LAYER5
"2112"944.51"85.96112"1048.8112"1346.81"1412.4112"1529.0112"1135.61"1216.3"2112""2"2112"BUILDINGLIMIT OF WORKMATCHLINEMATCHLINEPROPERTY LINE / LIMIT OF WORKMATCHLINEMATCHLINEPROPERTY LINE / LIMIT OF WORK302IRRIGATION GENERAL NOTES1.PRIOR TO BEGINNING ANY DEMOLITION ON SITE, THE CONTRACTORSHALL VISIT THE SITE & DOCUMENT THE EXISTING IRRIGATION SYSTEM TOA LEVEL SUFFICIENT TO DETERMINE:1.1. THAT ALL SYSTEM COMPONENTS, PIPING, WIRING AND OTHERMATERIALS ARE OF A SUFFICIENT WORKING ORDER TO FUNCTIONCORRECTLY.1.2. THAT THE BACKFLOW PREVENTION DEVICE ON THE EXISTING SYSTEMIS FUNCTIONAL. IF NOT, HE SHALL PROVIDE A NEW ONE.1.3. THAT THE EXISTING CONTROLLERS CAN ACCOMMODATE NEW ZONESAND/OR EXISTING ZONES MODIFIED WITHIN TCEQ DESIGN CRITERIATO ACCOMMODATE EXISTING ZONES. PROVIDE NEW CONTROLLEROR EXPAND EXISTING IF NECESSARY.1.4. IF EXISTING RAIN/FREEZE SENSOR IS PRESENT & FUNCTIONAL. IFNOT, PROVIDE ONE COMPATIBLE WITH CONTROLLER.1.5. WHAT MANUFACTURER IS CURRENTLY IN USE & PROVIDE SAMEBRAND OF EQUIPMENT TO MODIFIED ZONES.2. POINT OF CONNECTION IS APPROXIMATE. IRRIGATION CONTRACTORSHALL COORDINATE WITH OWNER'S REPRESENTATIVE REGARDING THEMOST FEASIBLE LOCATION FOR TAPPING AN EXISTING WATER SOURCE.THIS SHALL INCLUDE ANY MODIFIED ZONES AND ANY WIRING FROMEXISTING ZONES DAMAGED BY CONSTRUCTION ACTIVITIES.3. IRRIGATION CONTRACTOR IS RESPONSIBLE TO COORDINATE THEAPPROPRIATE ZONE WIRING BACK TO THE EXISTING SYSTEMCONTROLLER, INCLUDING ANY DATA OR SYSTEM CONTROL VALVEWIRING AS REQUIRED.4. IRRIGATION CONTRACTOR IS RESPONSIBLE TO EXAMINE THE PLANS INTHEIR ENTIRETY TO DETERMINE THE APPROXIMATE LOCATION OFEXISTING AND PROPOSED UTILITIES. HE SHALL ALSO CONTACT THEAPPROPRIATE AUTHORITY TO MARK UTILITIES ON THE SITE. THEIRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGESTO UTILITIES ON THE SITE CAUSED BY HIS WORK.5. CONTRACTOR SHALL EXAMINE THE SPECIFICATIONS AND DETAILS FORADDITIONAL REQUIREMENTS FOR THE IRRIGATION SYSTEM AND ITSINSTALLATION.6. IRRIGATION DRAWINGS ARE SCHEMATIC IN NATURE. AT TIMES MAINLINES, LATERALS AND VALVES MAY BE SHOWN IN PAVED AREAS OROUTSIDE THE PROPERTY LINE FOR PLAN CLARITY PURPOSES ONLY. THECONTRACTOR SHALL STAKE OUT IN THE FIELD ALL PRINCIPLE SYSTEMCOMPONENTS FOR APPROVAL BY THE OWNERS REPRESENTATIVE PRIORTO INSTALLATION.7. THE SYSTEM HAS BEEN DESIGNED TO FUNCTION WITH A MINIMUMDYNAMIC WATER PRESSURE OF 48 PSI AT A MINIMUM RATE OF 54 GPMAT THE POINT WHERE THE EXTENDED MAINLINE IS CONNECTED. THECONTRACTOR SHALL TAKE THREE READINGS (ONE AT 7:00 A.M., ONE AT12:00 P.M., AND ONE AT 7:00 P.M.) ON TWO SEPARATE DAYS ANDSUBMIT TO THE OWNERS REPRESENTATIVE FOR VERIFICATION OFPRESSURE PRIOR TO BEGINNING THE WORK.8. ALL TRENCHING WITHIN DRIP LINES OF EXISTING TREES SHALL BE BYHAND TOOLS. SHOULD ROOTS OVER 3" IN DIAMETER BE ENCOUNTEREDTHE CONTRACTOR MAY PROVIDE ANOTHER PIPE ROUTE IF LOCATION ISPROVIDED ON THE AS-BUILT DOCUMENTS.9. THE CONTRACTOR SHALL DEMONSTRATE TO AN OWNER'SREPRESENTATIVE THAT THE IRRIGATION SYSTEM IS FULLY FUNCTIONALAND RUNNING PROPERLY PRIOR TO FINAL ACCEPTANCE AND BEGINNINGOF THE WARRANTY PERIOD. THIS INCLUDES ANY EXISTING ZONESINSPECTED PER NOTE #1.10. NEW SYSTEM COMPONENTS ARE SHOWN. CONTRACTOR SHALL INCLUDEIN HIS PRICING THE FOLLOWING TASKS:10.1. FULL SITE WALK WITH OWNERS REPRESENTATIVE TO EXAMINECONTROLLERS, P.O.C.'S, WIRING, VALVES AND OTHER EXISTINGCOMPONENTS.10.2. PRODUCE A SHOP DRAWING SUBMITTAL TO SHOW ANY DEVIATIONSPROPOSED FOR THE PROPOSED SYSTEM ADAPTATION.10.3. PRODUCE AN AS-BUILT FILE MARK UP, LAMINATED AT 24"x36" OFTHE NEW COMPONENTS AND WHAT WAS DOCUMENTED PER NOTES & 9.C112"731.71"612.2112"423.41"518.7#1411""21"16.41112"222.7112"319.2"2WRANGLER DRIVEPROPERTY LINE / LIMIT OF WORKLIMIT OF WORKPROPERTY LINEBUILDINGLIMIT OF WORKMATCHLINEMATCHLINEMATCHLINEMATCHLINE24' FIRELANE & UTILITY EASEMENT50' LONE24' FIRE 15' WATER E SYMBOL MANUFACTURER/MODEL/DESCRIPTION HUNTER PROS-04-PRS30 5` STRIP SPRAYTURF SPRAY, 30 PSI REGULATED 4.0" POP-UP. HUNTER PROS-04-PRS30 8` RADIUSTURF SPRAY, 30 PSI REGULATED 4.0" POP-UP. HUNTER PROS-04-PRS30 10` RADIUSTURF SPRAY, 30 PSI REGULATED 4.0" POP-UP. HUNTER PROS-04-PRS30 12` RADIUSTURF SPRAY, 30 PSI REGULATED 4.0" POP-UP. HUNTER PROS-04-PRS30 15` RADIUSTURF SPRAY, 30 PSI REGULATED 4.0" POP-UP. HUNTER PGP-ADJ-BTURF ROTOR, 4.0" POP-UP. ADJUSTABLE ANDFULL CIRCLE. STANDARD ANGLE BLUE NOZZLE. HUNTER ICZ-101-25DRIP CONTROL ZONE KIT. 1" ICV GLOBE VALVEWITH 1" HY100 FILTER SYSTEM. PRESSUREREGULATION: 25PSI. FLOW RANGE: 2 GPM TO 20GPM. 150 MESH STAINLESS STEEL SCREEN. AREA TO RECEIVE DRIPLINE HUNTER PLD-06-12. IN-LINE PRESSURECOMPENSATING LANDSCAPE DRIPLINE WITHBUILT-IN CHECK VALVE. 0.6 GPH EMITTERS AT12" O.C. DRIPLINE LATERALS SPACED AT 18"APART, WITH EMITTERS OFFSET FOR TRIANGULARPATTERN.IRRIGATION SCHEDULE SYMBOL MANUFACTURER/MODEL/DESCRIPTION HUNTER PGV-151G1-1/2" PLASTIC ELECTRIC REMOTE CONTROLVALVE W/FLOW CONTROL. GLOBE CONFIGURATION. NIBCO T-113CLASS 125 BRONZE GATE SHUT OFF VALVE WITHWHEEL HANDLE, SAME SIZE AS MAINLINE PIPEDIAMETER AT VALVE LOCATION. EXISTING CONTROLLERTYPE AND LOCATION UNKNOWN. CONTRACTOR TOCONFIRM LOCATION AND MODEL OF EXISTINGCONTROLLER WITH OWNER'S REPRESENTATIVE. SEEIRRIGATION GENERAL NOTES. POINT OF CONNECTION 2"TAP EXISTING MAINLINE. VERIFY LOCATION WITHOWNER`S REP. PRIOR TO BEGINNING WORK. IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21ONLY LATERAL TRANSITION PIPE SIZES 1" ANDABOVE ARE INDICATED ON THE PLAN, WITH ALLOTHERS BEING 3/4" IN SIZE. IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 PIPE SLEEVE: PVC CLASS 200 SDR 212 SIZES LARGER THAN PIPE WITHIN.C#1Valve NumberValve CalloutValve FlowValve SizeNOTESDRAWNDESIGN DATE SCALEFILE NO.DATENO.REVISIONCITY OF COPPELL, DALLS COUNTY, TEXASDATENO. ISSUEPARK WEST COMMERCE CENTERLOT 3R, BLOCK 8ASTRAZENECA PARKING EXPANSIONASTRAZENECA PARKING EXPANSIONAPESDNAACERDLR XTEFOGERIATS TEASET TCCETSIHHARMAN 3146ANNE M.OWNER:FLUOR ENTERPRISES INC.100 FLUOR DANIEL DRIVEGREENSVILLE, SC 29607LANDSCAPE ARCHITECT:ANNE HARMANAHARMAN @PKCE.COMPACHECO KOCH CONSULTING ENGINEERS7557 RAMBLER ROAD, SUITE 1400DALLAS TEXAS 75231972-235-3031L3.0IRRIGATION PLAN1IRRIGATION PLAN1" = 20'-0"2IRRIGATION PLAN1" = 20'-0"
NOTESDRAWNDESIGN DATE SCALEFILE NO.DATENO.REVISIONCITY OF COPPELL, DALLS COUNTY, TEXASDATENO. ISSUEPARK WEST COMMERCE CENTERLOT 3R, BLOCK 8ASTRAZENECA PARKING EXPANSIONASTRAZENECA PARKING EXPANSIONAPESDNAACERDLR XTEFOGERIATS TEASET TCCETSIHHARMAN 3146ANNE M.OWNER:FLUOR ENTERPRISES INC.100 FLUOR DANIEL DRIVEGREENSVILLE, SC 29607LANDSCAPE ARCHITECT:ANNE HARMANAHARMAN @PKCE.COMPACHECO KOCH CONSULTING ENGINEERS7557 RAMBLER ROAD, SUITE 1400DALLAS TEXAS 75231972-235-3031L3.1IRRIGATION DETAILS*VALVE/BOX REQUIREMENTS, MAX. MANIFOLDING:- ONE 1 12" VALVE PER STANDARD VALVE BOX- TWO 1" VALVES PER STANDARD VALVE BOX- TWO 1 12" VALVES PER JUMBO VALVE BOX- THREE 1" VALVES PER JUMBO VALVE BOXAUTOMATIC SYSTEM VALVE1 1/2" = 1'-0"6"12" MIN4"WIRE IN CONDUIT UNDERPAVING ONLYMAIN LINE TOP OF PIPEAT 18" DEPTH3" DEPTH PEA GRAVELBRICK SUPPORT, EACH SIDE,AS NEEDED TO REACHCLEARANCE, TYP.SCH. 80 PVC NIPPLES,SAME AS VALVE SIZE, TYP.SPEARS SCH. 80 PVCBALL VALVEVALVE SIZED PER PLANSET BOX 2" ABOVEGRADE IN BED AREAS,1" IN TURF AREAS, TYP.VALVE BOXWATERPROOF SPLICES1DRIP ZONE VALVE ASSEMBLY-AT GRADE1 1/2" = 1'-0"WIRE IN CONDUIT UNDERPAVING ONLYPVC MAIN3" DEPTH PEA GRAVELBRICK SUPPORT,1 PER SIDE, TYP.SCH. 80 PVC NIPPLES,TYP.DRIP ZONE ASSEMBLYSCH. 80 PVC BALL VALVEWATERPROOF SPLICE KITS, TYP.SET BOX 2" ABOVEGRADE IN BED AREAS,1" IN TURF AREAS, TYP.VALVE BOX2BRASS GATE (ISOLATION) VALVE1 1/2" = 1'-0"3" DEPTH PEA GRAVELBRICK SUPPORT, 1 PER SIDE, TYP.PVC MALE ADAPTERS, TYP.BRASS GATE VALVE PER LEGENDSET BOX 2" ABOVE GRADE IN BEDAREAS, 1" IN TURF AREAS, TYP.10" ROUND VALVE BOX31'-0"ROTOR HEAD3" = 1'-0"EDGE OF WALK, CURBOR FACE OF WALLROTOR SET FLUSHSCH. 80 NIPPLE(LENGTH AS REQ.)SCH. 80 DOUBLE SWING(STREET EL AND ELBOW)SCH. 80 NIPPLE(10-12" LENGTH)SCH. 80 NIPPLESTREET ELPVC TEE OR EL4"CHECK VALVE HEADS AT LOWPOINTS OF ZONES4SPRAY HEAD3" = 1'-0"COMPACT SOIL AROUNDHEAD - SET TOP OF HEAD1/4" ABOVE FINISH GRADE4" POP-UP SPRAY PER LEGENDFLEX PIPE ASSEMBLYCLASS 200 PVCLATERAL LINES1'-0" MIN.1'-4" MAX.5DRIP TUBE INSTALLATION - AT GRADE3" = 1'-0"MULCH PER LANDSCAPE PLAN2" SOIL COVERDRIP TUBE STAKED AT 30" ON CENTER,ALL LOCATIONSTEES ALONG PVC HEADERLATERAL FEEDING HEADER6FROM VALVEDRIP ZONE TYPICAL ENLARGEMENT3/8" = 1'-0"FLUSH VALVE FOR MANUAL FLUSH,ONE END OF EXHAUST HEADER, TYP.HUNTER PLD-BVAIR RELEASE VALVE IN VALVE BOX, ONEPER ZONE AT HIGH CORNER, TYP.HUNTER PLD-AVRCLASS 200 PVC HEADER, TYP.BARBED FITTINGS BY MANUFACTURER, TYP.INSTALL DRIP RINGS ATTREE TRUNKS, TYP.IN- LINE EMITTER TUBING.SPACING PER LEGENDDRIP INDICATORHEAD7