Loading...
PD DRC CommentsT H £ • C 1 T Y • 0 F COPPELL T k � 9 g 1 Plan Case ID Address Plan Tvpe[Workclass Application Complete Date Case Manager Project Description Agency Building Engineering Fire Parks Planning PD18-08-000273 739 PLAZA BLVD CITY OF COPPELL DRC REPORT Planned Development - Detail PD - New/Not In Conformance 08/23/2018 PD -205R3 -HC, Quest Care, 743 Plaza Blvd COMMENTS T H £ • C i T Y • 0 F COPPELL T r A', - o E k 9 g 1A�" Project Name Vista Ridge (The Plaza), Lot 3, 4, BkD Reviewed By Review Date Plan Review Details Suzanne Arnold 08/30/2018 No comments Kent Collins 1. Break out Existing and Proposed utilities on the Preliminary Engineering on separate sheets 2. Verify fire hydrant spacing less than 300' 3. Clarify what happens to the existing 4" SS Service 4. Additional comments will be provided upon receipt of detailed engineering plans. Tim Oates 08/30/2018 1. Proposed light pole on west side should be located in a landscape island. 2. Existing fire lane at 700 N Denton Tap and proposed fire lane for this project need to be properly connected/aligned by plat. 3. Utility Plans: FDC line shall meet Engineering Details (4 -inch, not 6) John Elias 08/29/2018 1. Tree Survey needs to be seperated from the Landscape Plan, it needs to include totals for trees/inches removed, trees/inches preserved and trees/inches transplanted. Mary Paron-Boswell General - Sign Current sign layout does not comply with our ordinance. Cannot use Pans must be on a raceway or wireway, and use individually mounted channel letters raceway must be painted same color as building to blend in words "medical clinic" can be individually pin mounted if channel lettering does not work. - max. aggregate sq ft is 106 sq ft (frontage of bldg) 1 of 2 Elevations - Title Block Format: Questcare Clinic Vista Ridge (The Plaza) Addition Lot 3R, Block D 1.389 acres, Zoned PD -205R3 -HC Abstract City, County Date of Preparation - Please review Sec 12-22-5 Type of Exterior Construction #1-3 specifically - You do not meet the 80% masonry requirements — EIFS is not considered masonry Exterior wall surfaces — no more than 3 colors Please provide me with a color rendering Please produce a smaller color board T H £ • C 1 T Y • 0 F COPPELL 9 g 1 Plan Case ID PD18-08-000273 CITY OF COPPELL DRC REPORT 2of2 COMMENTS T H £ • C i T Y • 0 F COPPELL E k e s l a g Project Name Vista Ridge (The Plaza), Lot 3, 4, BkD Site Plan - Title Block Format: Questcare Clinic Vista Ridge (The Plaza) Addition Lot 3R, Block D 1.389 acres, Zoned PD -205R3 -HC Abstract City, County Date of Preparation - Vicinity Map o Scale at 1" = 1000' o Add North arrow o Add city limits o Add county line o Use black and white map Label fire riser dimensions Add note for patient drop-off area Provide adjacent lot info Remove contours from this sheet, add to utility plan Add note: outdoor lighting to be shielded Provide photometric plan add note that mechanical equipment must be screened add faux windows or fenestration/ architectural interest on the east side of the building facing Plaza Blvd, like adjacent building shave done. - do not count doors and windows in your calculations. Landscape Plan - Title Block Format: Questcare Clinic Vista Ridge (The Plaza) Addition Lot 3R, Block D 1.389 acres, Zoned PD -205R3 -HC Abstract City, County Date of Preparation - Vicinity Map o Scale at 1" = 1000' o Add North arrow o Add city limits o Add county line o Use black and white map - provide an overall landscape table, showing calculations for all lots in PD as required by the ordinance. - UNRESOLVED