Loading...
1st DRC Comment PD-272R5PD17-01-000118 Plan Case ID CITY OF COPPELL DRC REPORT Project Name , Lot , BkCOMMENTS 180 N Freeport PKWY Address Case Manager 09/22/2017 Application Complete Date Planned Development - Detail PD - In Conformance Plan Type / Workclass PD-272R5-LI, Prologis Park @ Callejo Project Description Agency Reviewed By Review Date Plan Review Details Building Suzanne Arnold 09/28/2017 No issues with site plan. Engineering George Marshall 09/28/2017 General - Civil Plans: • This is a preliminary review of the plans and does not constitute the first review of the civil plans. This is for the DRC process at this time. After the comments from DRC have been addressed then you may submit to the Engineering Department the civil plans for first review. • 5' wide sidewalk. • Revise grading around the retaining wall to not exceed a 4:1 slope. • It appears that the slopes between building 1 and 2 are at a 3:1 where the max slope Coppell allows is a 4:1. • Provide plan and profile for storm drains on one sheet. Plan view on top and profile on bottom. • Since these buildings are 2 separate lots, you need easements for the drainage lines just in case one lot is sold off in the future? •Move the hydrant on the west side of the building to be on the west side of the fire lane? • 3" tap requires a 3" meter. - UNRESOLVED Standard Detailed Engineering - • FYI comment - There may be additional comments gernerated upon detailed engineering review. • Show all proposed and existing fire hydrants on the site plan as well as the FDC. • Show pedestrian/handicap access from the sidewalk along the road to the building. • Add impervious and pervious area calculation to the site data table. • Fire lanes are to be against the curb. (Typ) • Staff ? Wouldn't any future gates need a site plan amendment? • Dimension concrete screen wall along the truck court. • Notes that reference specific details not included on the site plan need to be included with the submittal. See item #7. • Include reference to correct sheet numbers in general notes. See items #11 & 12. - UNRESOLVED Fire Tim Oates 09/28/2017 1. A2.02 - City of Coppell has adopted the 2015 International Code Series. 2. The 30-foot N/S drive aisle on east side of property shall be entirely fire lane easement 3. Louvers sizing/spacing was not evaluated...this will be done at building permit time once a Mechanical Engineer has submitted smoke control plans. 4. Show fire hydrants, existing and proposed, on the site plan. 1 of 2 PD17-01-000118 Plan Case ID CITY OF COPPELL DRC REPORT Project Name , Lot , BkCOMMENTS Parks John Elias 09/25/2017 No comments. Planning Mary Paron-Boswell Planning Matt Steer 1. Add property dimensions and finished floor elevations on all plans. 2. Include all existing and proposed easements (including access easements) on Site and Landscape Plan. 3. Include adjacent zoning information. 4. Fill in blanks within the General Notes. 5. Include PD Conditions approved with the conceptual plan. 6. Increase wing wall height from 10' to 12' to effectively screen the truck court. 7. Include Project name, subdivision name with lot and block, acreage and zoning number in the title block on all sheets. 8. Include contact person in the contact information. 9. Refer to the Site Plan checklist for all information required in the site data table (i.e. height, zoning PD number, FAR, impervious area). 10. Label and dimension sidewalks. 11.Indicate spacing between the driveways on the existing and adjacent properties. 12. Increase the width of the fire lane on the east side of the building to reflect actual drive aisle width. 13. Show and label dumpster and mechanical equipment areas. Ensure these are effectively screened. 14. Show lighting facilities on Site Plan and elevations. Provide photometric plan. 15. Include monument sign location on the Site Plan and details (Materials, colors, font, light source) on the elevations. 16. Include required and provided setbacks. Landscape Plan 1. Eastern Red Cedar symbol should match symbol in the legend. 2. Remove the site data table from the Landscape Plan. 3. Please indicate the total area devoted to landscaping. Elevations 1. Adjust the screen wall height from 10 to 12'. 2. Label all materials (including canopies, windows , vents, roll up doors, etc..) with colors. 3. Provide a color board with materials and color elevations at DRC. 2 of 2