COMMENT RESPONSES1 of 3 2805 Dallas Parkway, Suite 600 Plano, Texas 75093 Tel: 972.488.3880 Fax: 972.488.3882 www.jonescarter.com April 1, 2020 Mary Paron-Boswell City of Coppell 265 E Parkway Blvd, Coppell, Texas 75019 PO Box 9478 Re: Comment Response Letter – PD Zoning Review Plan Case ID #PD20-03-000415 Hilton Garden Inn Coppell, Dallas County, Texas Dear Mary Paron-Boswell: We are requesting approval of the above referenced PD Zoning submittal and have addressed the comments received on 03/27/2020. Below are the comments and our responses. Agency Reviewed By Review Date Plan Review Details Building Suzanne Arnold 03/25/2020 No comments Engineering Cole Baker 03/27/2020 Site Plan: - 30' minimum inside radius for fire lanes The entryway is 29’ wide. It was discussed with staff during the pre-development meeting that the fire radius could be reduced if the drive aisle was wider than 24’. We have run a vehicle tracking software to demonstrate that a 40’ fire truck can comfortably make the turn. The vehicle tracking is shown on the detail site plan. Landscape Plan: - Move tree away from storm drain inlet, wrap shrubs around inlets Addressed. - Move tree in northeast corner off of top of water line Addressed. - Recommend not placing trees near private water loop Addressed. Utility Plan: - No DCDA required for fire service, private fire line already has DCDAs Addressed. - Domestic service can't come from the fire line, needs to come from the city line to the north Addressed. - Move nothern FH line 10' away from proposed tree Addressed. - Move storm sewer line away from proposed trees Addressed. - Move fire service, FDC, and southern FH 10' away from proposed trees Addressed. - Recommend moving sanitary sewer service away from proposed tree Addressed. 2 of 3 2805 Dallas Parkway, Suite 600 Plano, Texas 75093 Tel: 972.488.3880 Fax: 972.488.3882 www.jonescarter.com Engineering Kumar Gali Fire Tim Oates 03/24/2020 1. Utility plan - if building is less than 100,000sf, FDC line to be 4-inch. Addressed. 2. Utility plan - fire hydrants required every 300lf along fire lane easement; water line loop around the building will be required with additional fire hydrants Addressed. 3. Fire riser room shall be minimum of 64sf with direct access from the exterior, show on site plan Addressed. Parks John Elias 03/25/2020 No comments Planning Mary Paron-Boswell Elevations - provide a colored exhibit Addressed. - label materials on the elevations Addressed. - provide a dumpster detail Addressed. - brick screening wall for dumpster enclosure Addressed. Dumpster enclosed with stone. - add pedestrian gate for dumpster Addressed. - provide a sign plan Signage to conform to city standards. - add more masonry to bldg. Addressed. - Review Sec. 12-22-5 (2) & (3) Will comply. - review pool screening requirements Will comply. - provide a material color board Please clarify – material board was provided at submittal. - Need to rename project we already have a Whitestone project Addressed. Landscaping - adjust title block for all sheets: - project name - plat name - lot #, Block # - acreage and zoning - label setbacks and utility easements Addressed. - Point West, not Whitestone Whitestone removed. - Landscape calculations provide not only what is required but also what is provided Addressed. - Accent trees are 3:1 for canopy trees Addressed. 3 of 3 2805 Dallas Parkway, Suite 600 Plano, Texas 75093 Tel: 972.488.3880 Fax: 972.488.3882 www.jonescarter.com Detail site plan - provide fire lane radii Fire lane radii are provided. The entryway is 29’ wide. It was discussed with staff during the pre-development meeting that the fire radius could be reduced if the drive aisle was wider than 24’. We have run a vehicle tracking software to demonstrate that a 40’ fire truck can comfortably make the turn. The vehicle tracking is shown on the detail site plan. - provide dumpster detail - brick wall dumpster required with pedestrian pass thru Please reference the elevations. - list width of porte cochere Addressed. - add to amenity table: Provide staff on-site 24 hrs/day Addressed. - provide ratio for parking count Addressed. - FIRE LANES ARE REQUIRED TO BE PLATTED, THEREFOR A PLAT WILL BE REQUIRED. IN SPEAKING WITH ENGINEERING THE UTILITY EASEMENT ON THE WESTERN PORTION OF THE ISTE CAN POSSIBLY BE ABANDONED IF I IS NOT BEING USED. Can the fire lane easement be dedicated by separate instrument? The lot is already platted. The utility easement on the western portion of the site contains an underground electric line. - The easement on the northern portion of the site can have accent trees placed in it, however, slide them as far south as possible away from the waterline. Addressed.