DRC CommentsSITE19-09-000381Plan Case ID
CITY OF COPPELL
DRC REPORT
Project Name , Lot , BkCOMMENTS
Address
Case Manager
09/16/2019Application Complete Date
Site Plan - Site PlanPlan Type/Workclass
Site Plan for 1.615 acres proposed retailProject Description
Agency Reviewed By Review Date Plan Review Details
Building Suzanne Arnold
Engineering Cole Baker 09/19/2019 General - N/A - UNRESOLVED
General - N/A - UNRESOLVED
Engineering Kumar Gali
Fire Tim Oates 1. Looped private fire line required. Water line should be be
private.
2. FDC adjacent to the fire hydrant should be 4-inch FDC line
with locking caps.
3. Need minimum of 6-inch underground for fire sprinkler - not
shown or not shown correctly - needs to have a double detector
check valve assembly in a vault at the street, looped around the
building to another double detector check valve assembly in a
vault at the street - fire sprinkler line off it into riser room.
4. Fire sprinkler riser room to be min 64sf with minimum
dimension of 8ft. Directly accessible from exterior.
Parks John Elias 1. Tree Survey is incomplete, needs to be stamped by LA.
Planning Mary Paron-Boswell General - Landscaping
-30% landscaping required. For lots under 2 ac you can have
up to 5% hardscape count towards landscaping - you may be
able to make the sidewalks around the building work with
integral colored concrete.
- Minimum sf for parking islands is 150 sf
- provide dimensions of landscape area ie min 10 ft at sides
and rear perimeters, min 20 at front perimeter. (15 for
perimeter and 5 for non-vehicular)
- need a tree at each end of parking island - need to add a
cople.
- provide a colored exhibit showing
interior/perimeter/non-vehicular landscaping area
- can't double dip on trees and area - UNRESOLVED
General - Site Plan
- Show all setbacks
- need waterline loop
- scale vicinity map 1"=1000'
- provide zoning of adjacent lots
- provide name and title of owners representative signing the
plat
- Correct title block. Lot 1, Block B
- Correct lot, block in PZ Secretary signature block
- Provide 4x3 blank space for Denton County filing
- Provide another 2x4 blank box for Dallas County filing
- need to provide a lighting plan and a photometric plan -
1 of 2
SITE19-09-000381Plan Case ID
CITY OF COPPELL
DRC REPORT
Project Name , Lot , BkCOMMENTS
UNRESOLVED
General - Tree Survey
- Need to provide a tree survey and mitigation plan that is
done by an arborist. need to provide information on trees
remaining and those being removed.
- pleas contact John Elias 972-462-5115 - UNRESOLVED
General - see plans for FDC comments - UNRESOLVED
2 of 2