Loading...
DRC CommentsSITE19-09-000381Plan Case ID CITY OF COPPELL DRC REPORT Project Name , Lot , BkCOMMENTS Address Case Manager 09/16/2019Application Complete Date Site Plan - Site PlanPlan Type/Workclass Site Plan for 1.615 acres proposed retailProject Description Agency Reviewed By Review Date Plan Review Details Building Suzanne Arnold Engineering Cole Baker 09/19/2019 General - N/A - UNRESOLVED General - N/A - UNRESOLVED Engineering Kumar Gali Fire Tim Oates 1. Looped private fire line required. Water line should be be private. 2. FDC adjacent to the fire hydrant should be 4-inch FDC line with locking caps. 3. Need minimum of 6-inch underground for fire sprinkler - not shown or not shown correctly - needs to have a double detector check valve assembly in a vault at the street, looped around the building to another double detector check valve assembly in a vault at the street - fire sprinkler line off it into riser room. 4. Fire sprinkler riser room to be min 64sf with minimum dimension of 8ft. Directly accessible from exterior. Parks John Elias 1. Tree Survey is incomplete, needs to be stamped by LA. Planning Mary Paron-Boswell General - Landscaping -30% landscaping required. For lots under 2 ac you can have up to 5% hardscape count towards landscaping - you may be able to make the sidewalks around the building work with integral colored concrete. - Minimum sf for parking islands is 150 sf - provide dimensions of landscape area ie min 10 ft at sides and rear perimeters, min 20 at front perimeter. (15 for perimeter and 5 for non-vehicular) - need a tree at each end of parking island - need to add a cople. - provide a colored exhibit showing interior/perimeter/non-vehicular landscaping area - can't double dip on trees and area - UNRESOLVED General - Site Plan - Show all setbacks - need waterline loop - scale vicinity map 1"=1000' - provide zoning of adjacent lots - provide name and title of owners representative signing the plat - Correct title block. Lot 1, Block B - Correct lot, block in PZ Secretary signature block - Provide 4x3 blank space for Denton County filing - Provide another 2x4 blank box for Dallas County filing - need to provide a lighting plan and a photometric plan - 1 of 2 SITE19-09-000381Plan Case ID CITY OF COPPELL DRC REPORT Project Name , Lot , BkCOMMENTS UNRESOLVED General - Tree Survey - Need to provide a tree survey and mitigation plan that is done by an arborist. need to provide information on trees remaining and those being removed. - pleas contact John Elias 972-462-5115 - UNRESOLVED General - see plans for FDC comments - UNRESOLVED 2 of 2