Loading...
SFLP - Preliminary Utility PlanLEGEND PROPERTY LINE EXISTING SANITARY SEWER AND MANHOLE EXISTING WATER AND FIRE HYDRANT SS PROPOSED SANITARY SEWER W PROPOSED WATER PROPOSED STORM LINE EASEMENT LINE EXISTING STORM LINE SS W W EXISTING GAS LINEGAS EXISTING OVERHEAD ELECTRICOHE PROPOSED GATE VALVE FIRE DEPARTMENT CONNECTION PROPOSED FIRE HYDRANT ASSEMBLY PROPOSED MANHOLE PROPOSED DOMESTIC METER PROPOSED IRRIGATION METER PROPOSED GRATE INLET PROPOSED WYE INLET EXISTING UNDERGROUND ELECTRICUGE PROPOSED GAS LINEGAS PROPOSED CURB INLET POWER POLE WATER NOTES: 1.CONTRACTOR TO NOTIFY ENGINEER IF EXISTING CONDITIONS VARY FROM THOSE SHOWN. 2.REFER TO MEP AND ARCHITECTURAL PLANS FOR CONNECTION TO DOWNSPOUTS AT BUILDINGS AND FLOWLINES. 3.CONTRACTOR SHALL NOTIFY ENGINEER IF EXISTING FLOWLINE ELEVATIONS DO NOT MATCH THOSE SHOWN ON THE PLAN. 4.CONTRACTOR TO ADJUST MANHOLE RIM ELEVATIONS TO MATCH FINISH GRADE. 5.CONTRACTOR TO REMOVE SILT AND DEBRIS FROM END OF EXISTING STORM SEWER PRIOR TO MAKING CONNECTION. 6.REFER TO CITY OF FRISCO CONSTRUCTION DETAILS AND SPECIFICATIONS. 7.ALL UTILITY STUBS SHOWN SHALL BE PLUGGED 5' PAST PROPOSED PAVEMENT EDGE OR 5' OUTSIDE THE BUILDING. 8.REFER TO TCEQ DESIGN GUIDELINES FOR ALL UTILITY CROSSINGS. 9.A 5-FOOT CLEARANCE SHALL BE MAINTAINED AROUND ALL FIRE HYDRANTS. 10.FIRE SPRINKLER LINE SHALL BE SIZED AND INSTALLED BY A STATE LICENSED FIRE SPRINKLER CONTRACTOR. 11.ALL WATER METERS SHALL BE LOCATED IN LANDSCAPE AREAS. 12.WATER TO HAVE A MINIMUM 4' OF COVER. 15' T.X.U. ELECTRIC COMPANY EASEMENT (VOL. 99172, PG. 16) D.R.D.C.T. 7.5' SIDEWALK & UTILITY EASEMENT (VOL. 99172, PG. 16) D.R.D.C.T. DRAINAGE EASEMENT (INST. NO. 201700240374) O.P.R.D.C.T. 10' SANITARY SEWER EASEMENT (INST. NO. 201700240374) O.P.R.D.C.T. SIDEWALK EASEMENT (INST. NO. 201700240374) O.P.R.D.C.T. WATER LINE EASEMENT (INST. NO. 201700240374) O.P.R.D.C.T. WATER LINE EASEMENT (INST. NO. 201700240374) O.P.R.D.C.T. SIDEWALK EASEMENT (INST. NO. 201700240374) O.P.R.D.C.T. 20' HIKE AND BIKE TRAIL EASEMENT (VOL. 98043, PG. 1) 10' UTILITY EASEMENT (VOL. 82137, PG. 690) D.R.D.C.T. 10' UTILITY EASEMENT (VOL. 82137, PG. 690) D.R.D.C.T. T.P. & L. EASEMENT (VOL. 71159, PG. 743) D.R.D.C.T. T.P. & L. EASEMENT (VOL. 71159, PG. 743) D.R.D.C.T. EXISTING 10' DRAINAGE EASEMENT VANNO PARKINGNO PARKINGNO PARKINGWWWWWWWWWWWWWW W W W W W W W W W W W W W W W W W W W W W WW WWWWWWWWWWW W W SS SSSSSSSS SSSSSSSST W W W W W TRACT 2 SFPLP HOLDINGS MANAGEMENT, LLC (INST. NO. 201200031715) O.P.R.D.C.T. 7.384 Acres 321,659 Square Feet LOT 3, BLOCK A GATEWAY BUSINESS PARK NO. 2 (INST. NO. 201700240374) O.P.R.D.C.T. FRITZ DRIVE (FORMERLY KNOWN AS COTTON ROAD) (57.50-FOOT WIDE RIGHT-OF-WAY) I N T E R S T A T E H I G HW A Y 6 3 5 (A L S O K N O W N A S L Y N D O N B . J O H N S O N F R E EW A Y ) (V A R I A B L E W I D T H R I G H T - O F - W A Y ) SFPLP HOLDINGS MANAGEMENT, LLC (INST. NO. 201200037650) O.P.R.D.C.T. S 56 ° 3 8' 0 6 " W 1 6 4. 3 9' S 68°23 ' 1 1 " W 1 6 0. 8 7' S 69°26' 2 2 " W 7 8 . 8 7' S 70°42 ' 3 1 " W 5 6 . 4 9 ' S 73°54'2 3 " W 1 0 4 . 9 8 ' S 75°29'38 " W 1 9 9 . 7 5 'S 37°25'01" W 60.69' S 64°3 3' 2 0 " W 9 5. 8 1'N 00°18'16" W 576.39'N 89°41'14" E 552.48'S 00°39'34" W 13.76' N 89°44'14" E 210.72'S 00°15'48" E 5.89'Δ=36°55'41"R=306.59'CB=S18°43'49"ECD=194.20'L=197.60' S 37°11'03" E 15.40' GI GI GI GI CI FH CI FH FH CI CI BACKFLOW PREVENTOR 8" WATER8" WATERLP LP LP LP LP LP FDC DOMESTIC SERVICE FH FH IRR. WMWM 8" WATER 8" WAT E R 8" WATERBACKFLOW PREVENTOR CONNECT TO EXISTING 12" WATER CONNECT TO EXISTING 12" WATER 1 2 MH MH CONNECT TO EXISTING MANHOLE 8" SEWER DOMESTIC SERVICE WITH METER 10' WATER EASEMENT EXISTING HEADWALL IRRIGATION SERVICE WITH METER PROPOSED HEADWALL EXISTING 60" RCP WM 1 EX. STORM EX. STORMEX. STORM EX. STORM EXISTING 60" RCP EX. WATERPROPOSED TRANSFORMER IRRIGATION SERVICE WITH METER PROPOSED 20' DRAINAGE EASEMENT WATER METER SCHEDULE SIZE NO.TYPEID NO. IRRIGATION (PD METER) 3" 1 2 2 1 PROPOSED PROPOSED 2" DOMESTIC (PD METER) 1 OF 1PRELIMINARY UTILITY PLANTYPICAL FIRE HYDRANT ASSEMBLY 12"/16" WL 6"SERVICEFIRE HYDRANT ASSEMBLY INCLUDES: 1 - 12"x6" TEE 1 - 6" VALVE 1 - 6" SERVICE 1 - FIRE HYDRANT NOTE: FIRE HYDRANT PER CITY STANDARDS 10' WATER ESMT. TYPICAL DOMESTIC METER & FIRE SERVICE 12"/16" WL 2" DOMESTICSERVICE8" FIRESERVICEREVISIONS REV NO.DATE DESCRIPTION DESIGNED BY: DATE: PROJECT NUMBER: SHEET NO. 2595 Dallas Parkway, Suite 101 BGE, Inc. Frisco, TX 75034 TBPE Registration No. F-1046 Tel: 972-464-4800 ●www.bgeinc.com Copyright 2020 CONTACT: 1-800-DIG-TESS 48 HOURS PRIOR TO CONSTRUCTION CAUTION !!!SFLP HOLDINGSLOT 3, BLOCK A!!CAUTION !! Contractor to Verify exact location & Depth of Exist Facilities Prior to any Construction Activities JTH FEBRUARY 2021 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY: 8499-00\\browngay.net\panzura\Regions\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_WATER PLAN.dwg Mar 02, 2021-7:42am jhaleBGE, INC.PROEJCT NAMETHESE PLANS ARE ISSUED FOR THE PURPOSE OF PRELIMINARY REVIEW AND ARE NOT INTENDED FOR CONSTRUCTION. WHEN ISSUED IN FINAL FORM THEY WILL BE SEALED, SIGNED AND DATED. RESPONSIBLE ENGINEER: BGE, INC. TEXAS REGISTERED ENGINEERING FIRM F-1046 JUSTIN F. LOECKER, P.E. TEXAS REGISTRATION NO. 136868 NKH 1250 S. FREEPORT PKWY. SFPLP HOLDINGS MANAGMENT LLC COPPELL, TEXAS 75019 OWNER/DEVELOPER Contact: Ralph Novak Tel: 817-851-4723 BM#1 "X" CUT SET ON CRUB, NORTH SIDE OF FRITZ DRIVE ±900' WEST OF THE CENTER LINE OF FREEPORT PARKWAY, ±70' WEST OF A FIRE HYDRANT AND ±10' SOUTH EAST OF A SLOW DOWN SIGN. NORTHING=7030476.91 EASTING=2424663.15 ELEV=522.40 BM#2 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE ±515' WEST OF THE CENTERLINE OF FREEPORT PARKWAY AND ±45' WEST OF A POWER POLE NORTHING=7030424.37 EASTING=2425062.84 ELEV=521.65 BM#3 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE, ±150' WEST OF THE CENTERLINE OF FREEPORT PARKWAY, ±70' WEST OF A POWER POLE AND ±70' WEST OF A NO PARKING SIGN. NORTHING=7030425.73 EASTING=2425429.21 ELEV=521.33 BM#4 "X" CUT SET ON SIDEWALK, WEST SIDE OF FREEPORT PARKWAY, ±20' NORTH OF A BRIDGE WALL, ±65' SOUTH OF A STORM MANHOLE AND ±20' NORTH OF THE END OF A GUARDRAIL. NORTHING=7030310.36 EASTING=2425575.38 ELEV=522.25 BENCH MARK LIST BEFORE YOU DIG, CALL DIG TESS 1-800-DIG-TESS !!WARNING!! EXISTING UNDERGROUND UTILITIES. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF ALL UTILITIES AND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION. ARCHITECT 1201 NORTH BOWSER ROAD HALFF ASSOCIATES, INC. RICHARDSON, TEXAS 75081 Contact: Alan Lafon Tel: 214-346-6200 LEGEND PROPERTY LINE EXISTING SANITARY SEWER AND MANHOLE EXISTING WATER AND FIRE HYDRANT SS PROPOSED SANITARY SEWER W PROPOSED WATER PROPOSED STORM LINE EASEMENT LINE EXISTING STORM LINE SS W W EXISTING GAS LINEGAS EXISTING OVERHEAD ELECTRICOHE PROPOSED GATE VALVE FIRE DEPARTMENT CONNECTION PROPOSED FIRE HYDRANT ASSEMBLY PROPOSED MANHOLE PROPOSED DOMESTIC METER PROPOSED IRRIGATION METER PROPOSED GRATE INLET PROPOSED WYE INLET EXISTING UNDERGROUND ELECTRICUGE PROPOSED GAS LINEGAS PROPOSED CURB INLET POWER POLE WATER NOTES: 1.CONTRACTOR TO NOTIFY ENGINEER IF EXISTING CONDITIONS VARY FROM THOSE SHOWN. 2.REFER TO MEP AND ARCHITECTURAL PLANS FOR CONNECTION TO DOWNSPOUTS AT BUILDINGS AND FLOWLINES. 3.CONTRACTOR SHALL NOTIFY ENGINEER IF EXISTING FLOWLINE ELEVATIONS DO NOT MATCH THOSE SHOWN ON THE PLAN. 4.CONTRACTOR TO ADJUST MANHOLE RIM ELEVATIONS TO MATCH FINISH GRADE. 5.CONTRACTOR TO REMOVE SILT AND DEBRIS FROM END OF EXISTING STORM SEWER PRIOR TO MAKING CONNECTION. 6.REFER TO CITY OF FRISCO CONSTRUCTION DETAILS AND SPECIFICATIONS. 7.ALL UTILITY STUBS SHOWN SHALL BE PLUGGED 5' PAST PROPOSED PAVEMENT EDGE OR 5' OUTSIDE THE BUILDING. 8.REFER TO TCEQ DESIGN GUIDELINES FOR ALL UTILITY CROSSINGS. 9.A 5-FOOT CLEARANCE SHALL BE MAINTAINED AROUND ALL FIRE HYDRANTS. 10.FIRE SPRINKLER LINE SHALL BE SIZED AND INSTALLED BY A STATE LICENSED FIRE SPRINKLER CONTRACTOR. 11.ALL WATER METERS SHALL BE LOCATED IN LANDSCAPE AREAS. 12.WATER TO HAVE A MINIMUM 4' OF COVER. 15' T.X.U. ELECTRIC COMPANY EASEMENT (VOL. 99172, PG. 16) D.R.D.C.T. 7.5' SIDEWALK & UTILITY EASEMENT (VOL. 99172, PG. 16) D.R.D.C.T. DRAINAGE EASEMENT (INST. NO. 201700240374) O.P.R.D.C.T. 10' SANITARY SEWER EASEMENT (INST. NO. 201700240374) O.P.R.D.C.T. SIDEWALK EASEMENT (INST. NO. 201700240374) O.P.R.D.C.T. WATER LINE EASEMENT (INST. NO. 201700240374) O.P.R.D.C.T. WATER LINE EASEMENT (INST. NO. 201700240374) O.P.R.D.C.T. SIDEWALK EASEMENT (INST. NO. 201700240374) O.P.R.D.C.T. 20' HIKE AND BIKE TRAIL EASEMENT (VOL. 98043, PG. 1) 10' UTILITY EASEMENT (VOL. 82137, PG. 690) D.R.D.C.T. 10' UTILITY EASEMENT (VOL. 82137, PG. 690) D.R.D.C.T. T.P. & L. EASEMENT (VOL. 71159, PG. 743) D.R.D.C.T. T.P. & L. EASEMENT (VOL. 71159, PG. 743) D.R.D.C.T. EXISTING 10' DRAINAGE EASEMENT VANNO PARKINGNO PARKINGNO PARKINGWWWWWWWWWWWWWW W W W W W W W W W W W W W W W W W W W W W WW WWWWWWWWWWW W SS SSSSSS SSSSSSSSSST W W W W W TRACT 2 SFPLP HOLDINGS MANAGEMENT, LLC (INST. NO. 201200031715) O.P.R.D.C.T. 7.384 Acres 321,659 Square Feet LOT 3, BLOCK A GATEWAY BUSINESS PARK NO. 2 (INST. NO. 201700240374) O.P.R.D.C.T. FRITZ DRIVE (FORMERLY KNOWN AS COTTON ROAD) (57.50-FOOT WIDE RIGHT-OF-WAY) I N T E R S T A T E H I G HW A Y 6 3 5 (A L S O K N O W N A S L Y N D O N B . J O H N S O N F R E EW A Y ) (V A R I A B L E W I D T H R I G H T - O F - W A Y ) SFPLP HOLDINGS MANAGEMENT, LLC (INST. NO. 201200037650) O.P.R.D.C.T. S 56 ° 3 8' 0 6 " W 1 6 4. 3 9' S 68°23 ' 1 1 " W 1 6 0. 8 7' S 69°26' 2 2 " W 7 8 . 8 7' S 70°42 ' 3 1 " W 5 6 . 4 9 ' S 73°54'2 3 " W 1 0 4 . 9 8 ' S 75°29'38 " W 1 9 9 . 7 5 'S 37°25'01" W 60.69' S 64°3 3' 2 0 " W 9 5. 8 1'N 00°18'16" W 576.39'N 89°41'14" E 552.48'S 00°39'34" W 13.76' N 89°44'14" E 210.72'S 00°15'48" E 5.89'Δ=36°55'41"R=306.59'CB=S18°43'49"ECD=194.20'L=197.60' S 37°11'03" E 15.40' GI GI GI GI CI FH CI FH FH CI CI BACKFLOW PREVENTOR 8" WATER8" WATERLP LP LP LP LP LP FDC DOMESTIC SERVICE FH FH IRR. WMWM 8" WATER 8" WAT E R 8" WATERBACKFLOW PREVENTOR CONNECT TO EXISTING 12" WATER CONNECT TO EXISTING 12" WATER 1 2 MH MH CONNECT TO EXISTING MANHOLE 8" SEWER DOMESTIC SERVICE WITH METER 10' WATER EASEMENT EXISTING HEADWALL IRRIGATION SERVICE WITH METER PROPOSED HEADWALL EXISTING 60" RCP WM 1 EX. STORM EX. STORMEX. STORM EX. STORM EXISTING 60" RCP EX. WATERPROPOSED TRANSFORMER IRRIGATION SERVICE WITH METER WATER METER SCHEDULE SIZE NO.TYPEID NO. IRRIGATION (PD METER) 3" 1 2 2 1 PROPOSED PROPOSED 2" DOMESTIC (PD METER) 1 OF 1PRELIMINARY UTILITY PLANTYPICAL FIRE HYDRANT ASSEMBLY 12"/16" WL 6"SERVICEFIRE HYDRANT ASSEMBLY INCLUDES: 1 - 12"x6" TEE 1 - 6" VALVE 1 - 6" SERVICE 1 - FIRE HYDRANT NOTE: FIRE HYDRANT PER CITY STANDARDS 10' WATER ESMT. TYPICAL DOMESTIC METER & FIRE SERVICE 12"/16" WL 2" DOMESTICSERVICE8" FIRESERVICEREVISIONS REV NO.DATE DESCRIPTION DESIGNED BY: DATE: PROJECT NUMBER: SHEET NO. 2595 Dallas Parkway, Suite 101 BGE, Inc. Frisco, TX 75034 TBPE Registration No. F-1046 Tel: 972-464-4800 ●www.bgeinc.com Copyright 2020 CONTACT: 1-800-DIG-TESS 48 HOURS PRIOR TO CONSTRUCTION CAUTION !!!SFLP HOLDINGSLOT 3, BLOCK A!!CAUTION !! Contractor to Verify exact location & Depth of Exist Facilities Prior to any Construction Activities JTH FEBRUARY 2021 CITY OF COPPELL, DALLAS COUNTY, TEXASCHECKED BY: 8499-00\\browngay.net\panzura\Regions\TXN\Projects\SFLP_Holdings_Management_LLC\8499-00-135408_SF_Ind_Bldg_Fritz_&_Freept_Pkwy\LD\01_CADD\01_Shts\SFLP_WATER PLAN.dwg Feb 11, 2021-4:03pm jhaleBGE, INC.PROEJCT NAMETHESE PLANS ARE ISSUED FOR THE PURPOSE OF PRELIMINARY REVIEW AND ARE NOT INTENDED FOR CONSTRUCTION. WHEN ISSUED IN FINAL FORM THEY WILL BE SEALED, SIGNED AND DATED. RESPONSIBLE ENGINEER: BGE, INC. TEXAS REGISTERED ENGINEERING FIRM F-1046 JUSTIN F. LOECKER, P.E. TEXAS REGISTRATION NO. 136868 NKH 1250 S. FREEPORT PKWY. SFPLP HOLDINGS MANAGMENT LLC COPPELL, TEXAS 75019 OWNER/DEVELOPER Contact: Ralph Novak Tel: 817-851-4723 BM#1 "X" CUT SET ON CRUB, NORTH SIDE OF FRITZ DRIVE ±900' WEST OF THE CENTER LINE OF FREEPORT PARKWAY, ±70' WEST OF A FIRE HYDRANT AND ±10' SOUTH EAST OF A SLOW DOWN SIGN. NORTHING=7030476.91 EASTING=2424663.15 ELEV=522.40 BM#2 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE ±515' WEST OF THE CENTERLINE OF FREEPORT PARKWAY AND ±45' WEST OF A POWER POLE NORTHING=7030424.37 EASTING=2425062.84 ELEV=521.65 BM#3 "X" CUT SET ON CURB INLET, SOUTH SIDE OF FRITZ DRIVE, ±150' WEST OF THE CENTERLINE OF FREEPORT PARKWAY, ±70' WEST OF A POWER POLE AND ±70' WEST OF A NO PARKING SIGN. NORTHING=7030425.73 EASTING=2425429.21 ELEV=521.33 BM#4 "X" CUT SET ON SIDEWALK, WEST SIDE OF FREEPORT PARKWAY, ±20' NORTH OF A BRIDGE WALL, ±65' SOUTH OF A STORM MANHOLE AND ±20' NORTH OF THE END OF A GUARDRAIL. NORTHING=7030310.36 EASTING=2425575.38 ELEV=522.25 BENCH MARK LIST BEFORE YOU DIG, CALL DIG TESS 1-800-DIG-TESS !!WARNING!! EXISTING UNDERGROUND UTILITIES. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF ALL UTILITIES AND COORDINATE WITH CORRESPONDING COMPANYPRIOR TO CONSTRUCTION. ARCHITECT 1201 NORTH BOWSER ROAD HALFF ASSOCIATES, INC. RICHARDSON, TEXAS 75081 Contact: Alan Lafon Tel: 214-346-6200