DRC- Elevations_v1Level 1
100'-0"
Level 2
114'-6"
PARAPET
133'-2"
ALUMINUM COMPOSITE METAL PANEL 'MT1',
RAINSCREEN SYSTEM, WHITE COLOR
GLAZING TO BE VRE-1-46 W/ SHGC
OF 0.28 OR BETTER, TYP.
ALUMINUM COMPOSITE METAL
PANEL 'MT1', RAINSCREEN
SYSTEM, WHITE COLOR
KAWNEER 1600 ALUMINUM
CURTAIN WALL SYSTEM, COLOR
TBD
GLAZING-INSULATED-1" (GLS3)
BRICK 'B1', STANDARD MODULAR
RUNNING BOND, CHARCOAL
COLOR.
GLAZING-INSULATED-1" (GLS3)
GLAZING TO BE VRE-1-46 W/ SHGC
OF 0.28 OR BETTER, TYP.
GLAZING-INSULATED-1" (GLS3)
ALUMINUM COMPOSITE METAL PANEL ' MT2',
RAINSCREEN SYSTEM, DARK GRAY COLOR
BRICK 'B1', STANDARD MODULAR RUNNING
BOND, CHARCOAL COLOR.
Level 1
100'-0"
Level 2
114'-6"
PARAPET
133'-2"
ALUMINUM COMPOSITE METAL PANEL 'MT1',
RAINSCREEN SYSTEM, WHITE COLOR
ALUMINUM COMPOSITE METAL
PANEL ' MT2', RAINSCREEN
SYSTEM, DARK GRAY COLOR
ALUMINUM COMPOSITE METAL
PANEL ' MT2', RAINSCREEN
SYSTEM, DARK GRAY COLOR
GLAZING TO BE VRE-1-46 W/ SHGC
OF 0.28 OR BETTER, TYP.
GLAZING-INSULATED-1" (GLS3)
BRICK 'B1', STANDARD MODULAR
RUNNING BOND, CHARCOAL
COLOR.
ALUMINUM COMPOSITE METAL
PANEL ' MT2', RAINSCREEN
SYSTEM, DARK GRAY COLOR
ALUMINUM COMPOSITE METAL PANEL 'MT1',
RAINSCREEN SYSTEM, WHITE COLOR
Level 1
100'-0"
Level 2
114'-6"
PARAPET
133'-2"
ALUMINUM COMPOSITE METAL
PANEL 'MT1', RAINSCREEN
SYSTEM, WHITE COLOR
GLAZING TO BE VRE-1-46 W/ SHGC
OF 0.28 OR BETTER, TYP.
GLAZING-INSULATED-1" (GLS3)GLAZING-INSULATED-1" (GLS3)ALUMINUM COMPOSITE METAL
PANEL ' MT2', RAINSCREEN
SYSTEM, DARK GRAY COLOR
GLAZING-INSULATED-1" (GLS3)
Level 1
100'-0"
Level 2
114'-6"
PARAPET
133'-2"
GLAZING TO BE VRE-1-46 W/ SHGC OF 0.28 OR
BETTER, TYP.
MODULAR BRICK W/ RUNNING BOND
PATTERN, CHARCOAL GRAY COLOR
GLAZING TO BE VRE-1-46 W/ SHGC
OF 0.28 OR BETTER, TYP.
ALUMINUM COMPOSITE METAL
PANEL 'MT1', RAINSCREEN
SYSTEM, WHITE COLOR
BRICK 'B2' STANDARD MODULAR
RUNNING BOND, WHITE COLOR.
GLAZING-INSULATED-1" (GLS3)
GLAZING TO BE VRE-1-46 W/ SHGC
OF 0.28 OR BETTER, TYP.
BRICK 'B2' STANDARD MODULAR
RUNNING BOND, WHITE COLOR.
BRICK 'B2' STANDARD MODULAR
RUNNING BOND, WHITE COLOR.
GLAZING-INSULATED-1" (GLS3)
1" DEEP BRICK NICHE, B1
STANDARD MODULAR
GLAZING TO BE VRE-1-46 W/ SHGC
OF 0.28 OR BETTER, TYP.
BRICK 'B1', STANDARD MODULAR
RUNNING BOND, CHARCOAL
COLOR.
GLAZING TO BE VRE-1-46 W/ SHGC
OF 0.28 OR BETTER, TYP.
NON-GLAZING AREA
TOTAL AREA MASONRY METAL PANEL GLAZING AREA
8,607.36 SF
SOUTH ELEVATION 14,009.35 SF 7,104.52 SF (82.54%) 1,502.84 SF 5,401.99 SF (38.56%)
9,988.31 SF
NORTH ELEVATION 13,706.87 SF 9,346.96 SF (93.58%) 641.35 SF 3,718.56 SF (27.13%)
5,828.40 SF
EAST ELEVATION 9,374.23 SF 4,388.14 SF (75.29%) 1,440.26 SF 3,545.83 SF (37.80%)
4,739.29 SF
WEST ELEVATION 9,104.41 SF 3,175.09 SF (67.99%) 1,564.20 SF 4,365.12 SF (47.95%)
29,163.36 SF
TOTAL 46,194.86 SF 24,014.71 SF (82.35%) 5,148.65 SF 17,031.50 SF (36.87%)
CHAPTER 12 ZONING, ARTICLE 22. " HC" HIGHWAY COMMERICAL DISTRICT REGULATIONS. CODE OF ORDINANCES, COPPELL
All structures shall be 80 percent masonry exterior exclusive of doors and windows. Stucco is permitted by special use permit only.
1. Masonry is further defined as brick and stone of earth tone colors, other brick colors shall be permitted as accent provided that, in combination,
accent materials and non-masonry materials do not exceed the 20 percent non-masonry benchmark on any one facade.
2. Flat roofs and parapet walls around flat roofs shall have a cornice, cap or other detail with a vertical dimension equal to at least three percent
of the height of the building. Where as architectural feature extends above the roof line, and is visible from a public right-of-way, then the back
side of this feature shall be finished of a material that is of the same or similar material as the front of this feature, i.e. brick. Pitched roofs shall
have roofing material of a lusterless neutral/earth tone or green color. Green colors shall be limited to dark forest greens, gray greens, pale
bluish-gray greens, slate greens and copper patina. Metal roofs may be standing seam either with a baked-on lusterless finish or made of copper.
3. Exterior wall surfaces should consist of no more than three colors; a base color, and/or a trim color, and/or an accent color. The base color
may be utilized on up to 100 percent of the surface area of any one facade of a building. Another color, other than a base color, shall be
permitted on up to only five percent of the surface area of any one facade, and an accent color on up to only one percent of the surface area of
any one facade. For calculation purposes, wall surfaces should include eaves, gables and parapets, but should exclude roofs, awnings, or signs.
4. Glass should not exceed 50 percent of the total area of any one facade of a building.
DATE SHEET
34.709 ACRES
DCCCD NORTH LAKE COLLEGE
CONSTRUCTION SCIENCES BUILDING
SCALE
As indicated A5.005/22/2019
BUILDING ELEVATIONS
LOT 1R, BLOCK 1
JESSE SURVEY ABSTRACT NO. 968 &
DUNNAGAN SURVEY ABSTRACT NO. 1665
SCALE: 1/16" = 1'-0"01 BUILDING ELEVATION - EAST
SCALE: 1/16" = 1'-0"02 BUILDING ELEVATION - WEST
SCALE: 1/16" = 1'-0"03 BUILDING ELEVATION - SOUTH
SCALE: 1/16" = 1'-0"04 BUILDING ELEVATION - NORTH
BECK ARCHITECTURE
1807 ROSS AVE
SUITE 500
DALLAS, TX 75201
PH: 214-303-6200
FAX: 214-303-6300
WWW.BECKARCHITECTURE.COM