DRC Comments.1stPD19-06-000335Plan Case ID CITY OF COPPELL DRC REPORT Project Name TRINTIY RIVER KAYAK, Lot 1, BkACOMMENTS Address Case Manager 06/17/2019Application Complete Date Planned Development - Detail PD - New/Not In ConformancePlan Type/Workclass 1601 E. SANDY LAKE ROAD - COVERED STORAGE AREASProject Description Agency Reviewed By Review Date Plan Review Details Building Suzanne Arnold 06/27/2019 Steel Canopy Building: 1. Building permit required. 2. Provide letter from a registered professional engineer attesting to the installation of the structure meeting the intent of the engineered plan. Storage Container: 1. Exceeds the 45 day allowance for portable storage and shipping containers in Section 15-14-2 #17. Staff cannot support the container remaining on site for more than 45 days. 2. If treated as a permanent structure, the shipping container does not meet material, placement, or construction standards in the non-residential accessory building regulations in Section 12-35-1 or Chapter 15. Live/Work Unit Classification: 1. Detailed floor plan required showing allocation of space between residential and commercial uses. 2. Section 15-1-2 amending International Building Code section 419.1.1 states: The first floor must be at least 50% non-residential; overall, the non-residential use can't be more than 50% of the building; therefore, a one-story live/work unit, by definition, must be exactly 50% residential and 50% non-residential. 3. Live/work units are required to have automatic fire sprinkler and alarm systems. 4. Residential portions are required to meet all building code requirements for dwellings; non-residential portions must meet all building codes for the commercial use. Engineering Kumar Gali 06/28/2019 1.Show FEMA floodplain boundaries on the site plan 2.Show the Establish erosion hazard setback line (https://library.municode.com/tx/coppell/codes/code_of_ordina nces?nodeId=CO_CH13SU_ART13-9DRSTSEST_S13-9- 1DRSTSESTTASU) 3.No permanent structures allowed in floodplain limits and erosion hazard setback line 4.If they are establishing single family residence use, then we need to see preliminary utility plan (water and sewer services to the building) Fire Tim Oates 06/27/2019 Fire Department has no comments related to this zoning change request. Parks John Elias 06/18/2019 No comments. Planning Matt Steer 06/28/2019 History: The property owner inquired about installing a shed in the front yard. Staff consulted with our Attorney and provided a letter stating that it was not allowed per the ordinance. Subsequently, the owner installed a the canopy and storage 1 of 2 PD19-06-000335Plan Case ID CITY OF COPPELL DRC REPORT Project Name TRINTIY RIVER KAYAK, Lot 1, BkACOMMENTS shed within the same front yard without seeking permits. 1. Staff cannot support this change to the PD: a. the canopy in the front yard does not meet the setback requirements of the platted lot (50' Front Yard) and reduces the parking for the convenience store. b. The storage units do not meet the setbacks requirements of the PD or base zoning. The metal container is highly visible from the properties to the south. 2. Verify that there is no boat storage separate and apart from the Kayak operation at this location. 3. Verify that the existing and proposed signage is in conformance with the previously approved PD. If not, please include the proposed changes. 2 of 2