Exhibit C - Tree Survey20'X28'
DRAINAGE
EASEMENT
SD SDMH
SS
SD
1/2" IRF
"PIBURN"
CM
1/2" IRF
1/2" IRF
1/2" IRS
"B&D"
1/2" IRS
"B&D"1/2" IRS
"B&D"
1/2" IRS
"B&D"
1/2" IRS
"B&D"
1/2" IRF
S89°56'14"E 105.99'
45.99'30.00'30.00'34.01'STOP SIGN TRAFFIC
SIGN
10' UTILITY EASEMENT
3' E.U.A.E.
3' E.U.A.E.20' BUILDING LINE15' BUILDING LINE
15' BUILDING LINE
VHH
VHH
TSB
5
0
8
509
50
9
5
0
9 5105
1
0510
510 510510 511511511512512512512513
513513
5
1
3
SSMH
Top=511.4'
Inaccessible
SDMH
Top=511.8'
Inaccessible
CONCRETE
PAD
APPROXIMATE LOCATION
OF UNDERGROUND GAS
LINE AS LOCATED IN FIELD
3' E.U.A.E.
EXISTING TREE
TO REMAIN, TYP.
EXISTING TREE TO BE
REMOVED, TYP.
251
249
248
245
247 LIVE/WORKDEVELOPMENTSheet Number:
Sheet Title:
Issue Date: 07/14/21
Drawn By:
Checked By:
Project Number: 21109
Revisions 560 S. COPPELL ROADCOPPELL, TX 75019aWRAWR Designs, LLCP.O. Box 1746Aledo, Texas 76008amanda@awr-designs.comc. 512.517.5589AWR
AWRSTA
TE O F T E XASTCETHI
R
C
A
EPACSDNALDEE
GEISRRT572 4AMANARICHDW.
A
RDSONTREE
PRESERVATION
PLAN
L1.01
GRAPHIC SCALE
FEET04020
SFDOH "=20
0"
TREE PRESERVATION LEGEND
TREE TO BE REMOVED
TREE TO REMAIN
TREE PRESERVATION FENCING
TREE PRESERVATION NOTES
CONSTRUCTION METHODS:
BORING: BORING OF UTILITIES UNDER PROTECTED TREES MAY BE REQUIRED.
WHEN REQUIRED, THE MINIMUM LENGTH OF THE BORE SHALL BE THE WIDTH
OF THE CRITICAL ROOT ZONE AND SHALL BE A MINIMUM DEPTH OF FORTY (48)
INCHES.
TRENCHING: ALL TRENCHING SHALL BE DESIGNED TO AVOID TRENCHING
ACROSS CRITICAL ROOT ZONES OF ANY PROTECTED TREE. THE PLACEMENT
OF UNDERGROUND UTILITY LINES SUCH AS ELECTRIC, PHONE, GAS, ETC., IS
ENCOURAGED TO BE LOCATED OUTSIDE THE CRITICAL ROOT ZONE.
TRENCHING FOR IRRIGATION SYSTEMS SHALL BE PLACED OUTSIDE THE
CRITICAL ROOT ZONE EXCEPT THE MINIMUM REQUIRED SINGLE HEAD SUPPLY
LINE. THIS LINE IS ALLOWED TO EXTEND INTO THE CRITICAL ROOT ZONE
PERPENDICULAR TO THE TREE TRUNK WITH THE LEAST POSSIBLE
DISTURBANCE.
TREES TO BE REMOVED: ALL TREES TO BE REMOVED FROM THE SITE SHALL BE
FLAGGED BY THE CONTRACTOR WITH BRIGHT RED VINYL TAPE WRAPPED
AROUND THE MAIN TRUNK AT A HEIGHT OF FOUR (4') FEET ABOVE GRADE.
TREES TO REMAIN: ALL TREES TO REMAIN, AS NOTED ON DRAWINGS, SHALL
HAVE PROTECTIVE FENCING LOCATED AT THE TREE'S DRIP LINE. THE
PROTECTIVE FENCING SHALL BE LOCATED AS INDICATED ON THE TREE
PROTECTION DETAIL.
EXISTING TREES NOTED TO REMAIN SHALL BE PROTECTED DURING
CONSTRUCTION FROM DAMAGE AND COMPACTION OF SOIL UNDER AND
AROUND DRIP LINE OF TREE.
UNDER NO CIRCUMSTANCE SHALL THE CONTRACTOR PRUNE ANY PORTION OF
THE DAMAGED TREE WITHOUT THE PRIOR APPROVAL BY THE OWNER'S
AUTHORIZED REPRESENTATIVE.
PROHIBITED ACTIVITIES IN CRITICAL ROOT ZONE:
THE FOLLOWING ACTIVITIES ARE PROHIBITED IN THE AREAS NOTED AS THE
CRITICAL ROOT ZONE.
MATERIAL STORAGE: NO MATERIALS INTENDED FOR USE IN CONSTRUCTION,
OR WASTE MATERIALS ACCUMULATED DUE TO EXCAVATION OR DEMOLITION,
SHALL BE PLACED WITHIN THE LIMITS OF THE CRITICAL ROOT ZONE OF ANY
PROTECTED TREE.
EQUIPMENT CLEANING/LIQUID DISPOSAL: NO EQUIPMENT SHALL BE CLEANED,
OR OTHER LIQUIDS DEPOSITED OR ALLOWED WITHIN THE LIMITS OF THE
CRITICAL ROOT ZONE OF A PROTECTED TREE. THIS INCLUDES, WITHOUT
LIMITATION: PAINT, OIL, SOLVENTS, ASPHALT, CONCRETE, MORTAR OR SIMILAR
MATERIALS.
TREE ATTACHMENTS: NO SIGNS, WIRES, OR OTHER ATTACHMENTS, OTHER
THAN THOSE OF A PROTECTIVE NATURE, SHALL BE ATTACHED TO ANY
PROTECTED TREE.
VEHICULAR TRAFFIC: NO VEHICULAR AND/OR CONSTRUCTION, EQUIPMENT,
TRAFFIC, OR PARKING SHALL TAKE PLACE WITHIN THE LIMITS OF THE CRITICAL
ROOT ZONE OF ANY PROTECTED TREE OTHER THAN ON EXISTING STREET
PAVEMENT.
GRADE CHANGES: A MINIMUM OF 75% OF THE DRIP LINE AND ROOT ZONE
SHALL BE PRESERVED AT NATURAL GRADE. ANY FINE GRADING DONE WITHIN
THE CRITICAL ROOT ZONES OF THE PROTECTED TREES MUST BE DONE WITH
LIGHT MACHINERY SUCH AS A BOBCAT OR LIGHT TRACTOR. NO EARTH MOVING
EQUIPMENT WITH TRACKS IS ALLOWED WITHIN THE CRITICAL ROOT ZONE OF
THE TREES.
PROCEDURES REQUIRED PRIOR TO CONSTRUCTION:
PROTECTIVE FENCING: PRIOR TO CONSTRUCTION, THE CONTRACTOR OR
SUBCONTRACTOR SHALL CONSTRUCT AND MAINTAIN, FOR EACH PROTECTED
TREE ON A CONSTRUCTION SITE, A PROTECTIVE FENCING WHICH ENCIRCLES
THE OUTER LIMITS OF THE CRITICAL ROOT ZONE OF THE TREE TO PROTECT IT
FROM CONSTRUCTION ACTIVITY. ALL PROTECTIVE FENCING SHALL BE IN
PLACE PRIOR TO COMMENCEMENT OF ANY SITE WORK, AND REMAIN IN PLACE
UNTIL ALL EXTERIOR WORK HAS BEEN COMPLETED.
BARK PROTECTION: IN SITUATIONS WHERE A PROTECTED TREE REMAINS IN
THE IMMEDIATE AREA OF INTENDED CONSTRUCTION, AND THE LANDSCAPE
ARCHITECT OR OWNERS'S REPRESENTATIVE DETERMINES THE TREE BARK TO
BE IN DANGER OF DAMAGE BY CONSTRUCTION EQUIPMENT OR OTHER
ACTIVITY, THE CONTRACTOR OR SUBCONTRACTOR SHALL PROTECT THE TREE
BY ENCLOSING THE ENTIRE CIRCUMFERENCE OF THE TREE WITH 2"X4" LUMBER
ENCIRCLED WITH WIRE OR OTHER MEANS THAT DO NOT DAMAGE THE TREE.
THE INTENT IS TO PROTECT THE BARK OF THE TREE AGAINST INCIDENTAL
CONTACT BY LARGE CONSTRUCTION EQUIPMENT.
TREE PROTECTION FENCING
N.T.S.
1
METAL T-POST 2'-3'
IN GROUND
ORANGE VINYL OR CHAIN LINK
FENCE TO REMAIN DURING
CONSTRUCTION
NO GRADING SHALL OCCUR
WITHIN LIMITS OF DRIPLINE
EXISTING TREE
NO ENTRY SIGNAGE
4' MIN.BORING:
BORING OF UTILITIES UNDER PROTECTED TREES SHALL BE REQUIRED IN CIRCUMSTANCES
WHERE IT IS NOT POSSIBLE TO TRENCH AROUND THE CRITICAL ROOT ZONE OF THE
PROTECTED TREE. WHERE REQUIRED, THE LENGTH OF THE BORE SHALL BE THE WIDTH OF
THE CRITICAL ROOT ZONE AT A MINIMUM AND SHALL BE A MINIMUM DEPTH OF FORTY EIGHT
(48") INCHES.
TRENCH =
40% ROOT KILL
TUNNELING
SAVES ROOTS
PROTECTED TREE
DRIP LINE
BORING AND TUNNELING
N.T.S.
2
WHERE A PROTECTED TREE REMAINS IN THE IMMEDIATE AREA OF INTENDED CONSTRUCTION, AND
THE TREE MAY BE IN DANGER OF BEING DAMAGED BY CONSTRUCTION EQUIPMENT OR OTHER
ACTIVITY, THE CONTRACTOR OR SUBCONTRACTOR SHALL PROTECT THE TREE WITH 2" X 4" LUMBER
ENCIRCLED WITH WIRE OR OTHER MEANS THAT DO NOT DAMAGE THE BARK OF THE TREE. THE
INTENT IS TO PROTECT THE TRUNK OF THE TREE AGAINST INCIDENTAL CONTACT BY LARGE
CONSTRUCTION EQUIPMENT.
2" X 4" LUMBER
WIRE
FINISH GRADE
BARK PROTECTION
N.T.S.
3